Zobrazeno 1 - 10
of 45
pro vyhledávání: '"Matthias Schreiter"'
Autor:
Matthias Schreiter, Inger Vikholm-Lundin, Dana Pitzer, Ann-Charlotte Hellgren, Sanna Auer, Kari Tukkiniemi, Arto Rantala, Martin Nirschl
Publikováno v:
Sensors, Vol 10, Iss 5, Pp 4180-4193 (2010)
The throughput is an important parameter for label-free biosensors. Acoustic resonators like the quartz crystal microbalance have a low throughput because the number of sensors which can be used at the same time is limited. Here we present an array o
Externí odkaz:
https://doaj.org/article/2432fa5cf63e4b7488c75601e34a5460
Autor:
Günther Zeck, Clemens Boucsein, Stefan Keil, Florian Jetter, Gabriel Bertotti, Roland Thewes, Normal Dodel, Matthias Schreiter, Dirk Wolansky, Karl-Heinz Boven
Publikováno v:
IEEE Electron Device Letters. 38:967-970
The effect of optical stimulation of neural tissue is considered in capacitively coupled CMOS microelectrode arrays used for in vitro extracellular recording from neural tissue. Using a 25-nm high-k TiO2 sensor dielectric with 20% ZrO2, light-induced
Publikováno v:
Journal of Sensors and Sensor Systems. 6:87-96
Carbon dioxide (CO2) is a gas that well represents air quality in indoor environments as well as being an important greenhouse gas. However, the reliable and affordable sensing of environmental CO2 at room temperature, with techniques other than opti
Autor:
Alexander Frey, Thorsten Hehn, Marcell Thewes, Matthias Schreiter, Ingo Kühne, Gerd Scholl, Xiaoming Li, Yiannos Manoli, Dieter Wagner
Publikováno v:
tm - Technisches Messen. 80:92-97
Zusammenfassung In der vorliegenden Arbeit wird ein kurzer Abriss zur energieautarken Sensorik im Automobil gegeben. Hierzu wird auf die Vielfalt der Sensoren im heutigen Kraftfahrzeug eingegangen und eine Motivation bezüglich der Substitution hin z
Systementwurf eines MST basierten piezoelektrischen Versorgungsmoduls für energieautarke Anwendungen
Publikováno v:
teme. 80:53-60
Zusammenfassung Der Systementwurf eines piezoelektrischen Versorgungsmoduls für ein energieautarkes Reifendruck-Kontrollsystems (RDKS) wird beschrieben. Hierfür werden der Generatorentwurf unter Einbeziehung des piezoelektrischen Materialsystems so
Publikováno v:
Tagungsband.
FBARs (engl. Film Bulk Acoustic Resonator) konnen durch eine entsprechende Oberflachenfunktionalisierung sensitiv fur bestimmte Molekule gemacht werden. Die Molekule lagern sich an der Oberflache an und bewirken somit eine Resonanzveranderung, welche
Publikováno v:
Micro and Nanosystemse. 4:111-117
Thin-film bulk acoustic resonators (FBAR) can be used as mass sensors when the adsorbed mass is linear to the frequency shift caused by the adsorption. This is, however, only the case if the adsorbed layer is thin compared to the thickness of the res
Publikováno v:
Sensors and Actuators A: Physical. 165:415-421
Unlike the quartz crystal microbalance, which has been used extensively for the analysis of biochemical interactions, only few measurements with biochemical adsorbent have been done with film bulk acoustic resonators (FBAR). In this paper, the FBAR b
Publikováno v:
Auer, S, Nirschl, M, Schreiter, M & Vikholm-Lundin, I 2011, ' Detection of DNA hybridisation in a diluted serum matrix by surface plasmon resonance and film bulk acoustic resonators ', Analytical and Bioanalytical Chemistry, vol. 400, no. 5, pp. 1387-1396 . https://doi.org/10.1007/s00216-011-4871-0
Nanomolar quantities of single-stranded DNA products ∼100 nucleotides long can be detected in diluted 1% serum by surface plasmon resonance (SPR) and film bulk acoustic resonators (FBARs). We have used a novel FBAR sensor in parallel with SPR and o
Autor:
Sanna Auer, Dana Pitzer, Inger Vikholm-Lundin, Ann-Charlotte Hellgren, Kari Tukkiniemi, Martin Nirschl, Matthias Schreiter, Arto Rantala
Publikováno v:
Sensors, 10 (5)
Sensors
Volume 10
Issue 5
Pages: 4180-4193
Nirschl, M, Rantala, A, Tukkiniemi, K, Auer, S, Hellgren, A-C, Pitzer, D, Schreiter, M & Vikholm-Lundin, I 2010, ' CMOS-integrated film bulk acoustic resonators for label-free biosensing ', Sensors, vol. 10, no. 5, pp. 4180-4193 . https://doi.org/10.3390/s100504180
Sensors (Basel, Switzerland)
Sensors, Vol 10, Iss 5, Pp 4180-4193 (2010)
Sensors
Volume 10
Issue 5
Pages: 4180-4193
Nirschl, M, Rantala, A, Tukkiniemi, K, Auer, S, Hellgren, A-C, Pitzer, D, Schreiter, M & Vikholm-Lundin, I 2010, ' CMOS-integrated film bulk acoustic resonators for label-free biosensing ', Sensors, vol. 10, no. 5, pp. 4180-4193 . https://doi.org/10.3390/s100504180
Sensors (Basel, Switzerland)
Sensors, Vol 10, Iss 5, Pp 4180-4193 (2010)
The throughput is an important parameter for label-free biosensors. Acoustic resonators like the quartz crystal microbalance have a low throughput because the number of sensors which can be used at the same time is limited. Here we present an array o