Zobrazeno 1 - 10
of 161
pro vyhledávání: '"Matthew R, Myers"'
Autor:
Prasanna Hariharan, Neha Sharma, Suvajyoti Guha, Rupak K. Banerjee, Gavin D’Souza, Matthew R. Myers
Publikováno v:
Scientific Reports, Vol 11, Iss 1, Pp 1-19 (2021)
Abstract In the absence of fit-testing, leakage of aerosolized pathogens through the gaps between the face and N95 respirators could compromise the effectiveness of the device and increase the risk of infection for the exposed population. To address
Externí odkaz:
https://doaj.org/article/99ad9058a158414394a2748c325b69a5
Autor:
Suvajyoti Guha, Alexander Herman, Ian A Carr, Daniel Porter, Rucha Natu, Shayna Berman, Matthew R Myers
Publikováno v:
PLoS ONE, Vol 16, Iss 1, p e0244626 (2021)
BackgroundFace coverings constitute an important strategy for containing pandemics, such as COVID-19. Infection from airborne respiratory viruses including Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) can occur in at least three modes
Externí odkaz:
https://doaj.org/article/10dc10211c19442183454711679e9fc7
Autor:
Suvajyoti Guha, Alexander Herman, Luke Herbertson, Mark J Antonino, Joshua S Silverstein, Jeffrey Cooper, Matthew R Myers
Publikováno v:
PLoS ONE, Vol 15, Iss 7, p e0236644 (2020)
BackgroundGastrostomy tubes (G-tubes) are typically used when people cannot eat food by mouth. The connector section that allows G-tubes to connect to other devices, such as feeding sets or syringes, has been modified on some of the devices to reduce
Externí odkaz:
https://doaj.org/article/22660a8448094829a18ddeee32e7b5aa
Autor:
Suvajyoti Guha, Alexander Herman, Mark Antonino, Joshua S. Silverstein, Priya Venkataraman‐Rao, Matthew R. Myers
Publikováno v:
Nutrition in Clinical Practice. 37:752-761
Misconnections between enteral devices and other medical devices have been associated with patient death and serious injuries. To minimize such misconnections, the design of connectors on enteral devices has been standardized. The most common adaptat
Publikováno v:
Annual Review of Heat Transfer. 24:435-461
Publikováno v:
PLoS ONE, Vol 13, Iss 11, p e0206937 (2018)
OBJECTIVES:For electronic nicotine delivery systems (ENDS), also commonly called e-cigarettes, coil temperature is a factor in the potential production of toxic chemical constituents. However, data are lacking regarding the temperatures that are achi
Externí odkaz:
https://doaj.org/article/c14406dfad4647fc87a90eb4a5075231
Autor:
Surendra Balaji Devarakonda, Matthew R Myers, Dushyanth Giridhar, Seyed Ahmad Reza Dibaji, Rupak Kumar Banerjee
Publikováno v:
PLoS ONE, Vol 12, Iss 4, p e0175093 (2017)
Collateral damage and long sonication times occurring during high-intensity focused ultrasound (HIFU) ablation procedures limit clinical advancement. In this reserarch, we investigated whether the use of magnetic nano-particles (mNPs) can reduce the
Externí odkaz:
https://doaj.org/article/b86776496bbe4a0dbb63efd3e6559219
Autor:
Prasanna Hariharan, Gavin A D'Souza, Marc Horner, Tina M Morrison, Richard A Malinauskas, Matthew R Myers
Publikováno v:
PLoS ONE, Vol 12, Iss 6, p e0178749 (2017)
A "credible" computational fluid dynamics (CFD) model has the potential to provide a meaningful evaluation of safety in medical devices. One major challenge in establishing "model credibility" is to determine the required degree of similarity between
Externí odkaz:
https://doaj.org/article/29b20fa88074492a8a92cfdca43d4f51
Autor:
Nandini Duraiswamy, George Gibeily, Veronica Price, Prasanna Hariharan, Alexander B. Herman, Matthew R. Myers, Poulomi Nandy
Publikováno v:
Journal of Minimally Invasive Gynecology. 27:655-664
Study Objective To determine the ability of tissue containment systems to prevent leakage of cancer cell surrogates when subjected to forces encountered during power morcellation procedures. Design In vitro study. Setting Medical device research labo
Autor:
Surendra B. Devarakonda, Rupak K. Banerjee, Matthew R. Myers, Marepalli B. Rao, Keith F. Stringer
Publikováno v:
ACS Biomaterials Science & Engineering. 5:4102-4111
An in vivo study was conducted using a mouse tumor model, to assess the utility of using gold nanoparticles (gNPs) during HIFU procedures to locally enhance heating at low powers. Tumors were grown using melanoma tumor cells (B16/F10) subcutaneously