Zobrazeno 1 - 10
of 66
pro vyhledávání: '"Masami Ogita"'
Publikováno v:
Journal of the American Ceramic Society. 90:2879-2884
Resistive oxygen sensors based on gallium oxide were fabricated in order to analyze their sensing performances (as sensitivity, response, and recovery time) in an oxygen atmosphere at 1000°C. We prepared three types of sensors using a β-Ga2O3 singl
Publikováno v:
Transactions of the Materials Research Society of Japan. 32:1195-1198
Publikováno v:
Thin Solid Films. 484:369-373
In this paper oxygen sensor based on gallium oxide thin films has been analyzed. The gallium oxide thin films were prepared by rf magnetron sputtering from a powder target using Ar as the sputtering gas. The sensing characteristics (stability, sensit
Publikováno v:
Applied Surface Science. 244:199-202
We present a sol–gel derived coating optical fiber sensors for measurement of critical micelle concentration of surfactants. A sol–gel process for making porous silica and coat the fiber core with sensing material is described. CMC detection is b
Publikováno v:
Japanese Journal of Applied Physics. 43:7213-7216
In this paper an oxygen sensor based on Ga2O3 films was analyzed. We propose a sensor using a Pt–Ga2O3–Pt structure with a bottom Pt layer electrode and a mesh type Pt electrode atop the Ga2O3 film. Ga2O3 films were prepared by rf magnetron sputt
Autor:
Tatsuya Orima, Masami Ogita, Haruhiko Naito, Keishi Kondo, Hiroshi Shiroto, Seiichi Minami, Hirofumi Adachi, Tomonori Hamada, Nozomi Minagawa
Publikováno v:
The Japanese Journal of Gastroenterological Surgery. 37:345-349
大腸癌の根治度A, B手術後に腹膜再発をきたした18例のうち7例 (手術群) に可及的転移巣摘出とMMC腹腔内散布を行った. このうち4例はCEA値上昇のみで試験開腹, 3例は腫瘤触知ないし画像診
Publikováno v:
Breast Cancer. 11:69-72
Experience with conserving surgery for lobular carcinoma has grown as more breast conserving surgeries have been performed. We examined the results of breast conserving therapy in lobular carcinoma.We examined the postoperative positive margin rate,
Publikováno v:
Japanese Journal of Applied Physics. 42:7594-7598
Thick film NO2 sensors comprised of various Zn–Sn–Sb–O composite materials have been studied. The gas-sensing materials were prepared by sintering a mixture of ZnO, SnO2 and Sb2O3 powders at 800, 1000 and 1200°C. Thick films were fabricated on
Autor:
Masami Ogita, Yasushi Yamada
Publikováno v:
Sensors and Actuators B: Chemical. 93:546-551
The transient resistance response of a SnO2 sensor after an abrupt temperature change was measured, and consequently peculiar responses of the sensor in NO2 gas were observed. SnO2 thick film sensors, with a thickness of approximately 10 μm, were pr
Publikováno v:
Sensors and Actuators B: Chemical. 92:44-48
In this paper, the detection of gases using attenuated total internal reflection (ATR) technique has been theoretically described in multimode step-index, tapered fiber with porous cladding. Using a modal approach the response time and sensitivity of