Zobrazeno 1 - 10
of 35
pro vyhledávání: '"Masakazu Hisatsune"'
Autor:
Masakazu Hisatsune
Publikováno v:
Journal of Nuclear Engineering and Radiation Science. 8
Autor:
Koji Shiina, Iwahara Kotaro, Hamada Noriaki, Kuniyoshi Tsubouchi, Masakazu Hisatsune, Masaya Ohtsuka
Publikováno v:
TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B. 79:1309-1318
Autor:
Akitaka Hidaka, Katsumasa Miyazaki, Kotoji Ando, Masakazu Hisatsune, Yoshio Urabe, Sota Watanabe, Koji Takahashi
Publikováno v:
Nuclear Engineering and Design. 239:2719-2727
Low cycle fatigue tests were conducted using 100A elbow specimens made of STPT410 carbon steel with local wall thinning. Local wall thinning by erosion/corrosion was simulated by machined pipe wall thinning. The local wall thinning areas were located
Publikováno v:
Solid State Phenomena. 120:85-94
To achieve a rational maintenance program for aged Light Water Reactor components, it is important to establish and to improve the flaw evaluation criteria. The current flaw evaluation criteria such as ASME Boiler and Pressure Vessel Code Section XI
Publikováno v:
Nuclear Engineering and Design. 237:335-341
Monotonic four-point bending tests were conducted using pipe specimens having an orifice undergoing local wall thinning. The effects of local wall thinning on the fracture behaviors of pipe were investigated. Local wall thinning was machined on the i
Publikováno v:
Nuclear Engineering and Design. 237:137-142
Monotonic four-point bending tests were conducted using tee pipe specimens having local wall thinning. The effects of local wall thinning on the fracture behaviors of tee pipes were investigated. Local wall thinning was machined on the inside of pipe
Autor:
Shoichi Moriya, Tadashi Mizuno, Kenji Ogura, Haruki Madarame, Masakazu Hisatsune, Kouichi Tanimoto, Tsutomu Kawamura, Kouji Shiina, Toshihiko Fukuda, Masaya Ohtsuka, Yasuhiko Minami
Publikováno v:
Heat Transfer—Asian Research. 36:38-55
In a branch pipe with one closed end, the cavity flow penetrates into the branch pipe from the main loop and a thermal boundary layer occurs because the cavity flow is a hot fluid, but heat removal causes a colder fluid in the branch pipe. This therm
Autor:
Tadashi Mizuno, Masaya Ohtsuka, Shoichi Moriya, Kenji Ogura, Tsutomu Kawamura, Kouichi Tanimoto, Yasuhiko Minami, Toshihiko Fukuda, Kouji Shiina, Haruki Madarame, Masakazu Hisatsune
Publikováno v:
TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B. 71:954-961
In a branch pipe with closed end, the cavity flow penetrates into the branch pipe from the main loop and the thermal boundary layer occurs because the cavity flow in a hot fluid, but the heat removal causes the colder fluid in the branch pipe. It is
Publikováno v:
Volume 8: Seismic Engineering.
This paper provides a part of series of “Development of an Evaluation Method for Seismic Isolation Systems of Nuclear Power Facilities” [1]–[4]. This part describes the work schedule of this project and the summary of a seismic design for cross
Autor:
Katsumasa Miyazaki, Kazuya Matsuo, Kyohei Sato, Yoshio Urabe, Masakazu Hisatsune, Akitaka Hidaka, Kotoji Ando, Koji Takahashi
Publikováno v:
ResearcherID
Low-cycle fatigue tests and finite element analysis were conducted using 100A elbow specimens made of STPT410 with local wall thinning in order to investigate the influences of local wall thinning on the low-cycle fatigue behaviors of elbows with int