Zobrazeno 1 - 10
of 55
pro vyhledávání: '"Masahiro Hashida"'
Publikováno v:
Nihon Hoshasen Gijutsu Gakkai zasshi. 77(10)
When the fat-suppression technique was used in the MRI examinations of neck and extremities, incomplete regions of fat suppression were depicted frequently. These incomplete regions were caused by the non-uniform static magnetic field (B0). On the ot
Autor:
Yuya Yamatani, Masahiro Hashida, Yoshihiro Matsuura, Makoto Nagayoshi, Eiji Yamada, Tsukasa Doi, Tadashi Miyanishi
Publikováno v:
Nihon Hoshasen Gijutsu Gakkai zasshi. 75(11)
PURPOSE The purpose of this paper is to analyze the characteristics of incidents related to routes and drains that occur in the radiological examination room for the prevention of these incidents. METHODS We conducted a questionnaire survey on incide
Autor:
Tadashi Miyanishi, Masahiro Hashida, Yuya Yamatani, Yoshihiro Matsuura, Tsukasa Doi, Eiji Yamada, Makoto Nagayoshi
Publikováno v:
Nihon Hoshasen Gijutsu Gakkai zasshi. 75(11)
We analyzed 197 fall incidents in the questionnaire survey about the incident that occurred in Department of Radiology. In the past paper about the patient safety, there is no report that evaluated incident data directly. The purpose of this paper is
Autor:
Tadashi Miyanishi, Makoto Nagayoshi, Yoshihiro Matsuura, Masahiro Hashida, Tsukasa Doi, Yuya Yamatani, Eiji Yamada
Publikováno v:
Nihon Hoshasen Gijutsu Gakkai zasshi. 75(11)
We conducted a questionnaire survey (situation, patient factor, environmental factor, operator factor, degree of disability, countermeasure etc.) on cases that occurred up to the present to investigate the actual situation of the medical accidents th
Publikováno v:
Radiological Physics and Technology
The ability to predict hazards in possible situations in a general X-ray examination room created for Kiken-Yochi training (KYT) is quantified by use of free-response receiver-operating characteristics (FROC) analysis for determining whether the tota
Publikováno v:
Japanese Journal of Radiological Technology. 75:1247-1248
Autor:
Junji Shiraishi, Masahiro Hashida
Publikováno v:
Japanese Journal of Radiological Technology. 71:99-107
In the past 10 years at our university hospital, 202 incident reports related to tasks performed by radiological technologists were posted. In order to investigate the causes and trends of these incidents, we classified the incident reports into four
Autor:
Kiyotaka Kakei, Yuji Nakaguchi, Tetsuo Saito, Masato Maruyama, Eriko Takenaga, Ryuji Murakami, Masahiro Hashida, Nozomu Nagasue, Yudai Kai
Publikováno v:
Japanese Journal of Radiological Technology. 70:34-40
Purpose We developed a quality assurance (QA) phantom to enable easy confirmation of radiation source output measurements of a high dose rate (192)Ir intracavitary brachytherapy unit in gynecology. The purpose of this study was to evaluate the feasib
Autor:
Masanori Komi, Toshinori Hirai, Tomohiro Namimoto, Kosuke Morita, Yasuyuki Yamashita, Seiji Takashio, Daisuke Utsunomiya, Megumi Yamamuro, Seitaro Oda, Masahiro Hashida
Publikováno v:
Academic Radiology. 20:752-757
To compare free-breathing three-dimensional (3D) phase-sensitive inversion recovery (PSIR) with breath-holding two-dimensional (2D) IR sequences to determine which is better for detecting and characterizing myocardial late gadolinium enhancement (LGE
Publikováno v:
Nihon Hoshasen Gijutsu Gakkai zasshi. 72(7)
This study was conducted to measure the recognition time of the test pattern and to investigate the effects of the maximum luminance in a medical-grade liquid-crystal display (LCD) on the recognition time. Landolt rings as signals of the test pattern