Zobrazeno 1 - 7
of 7
pro vyhledávání: '"Masahiro Arioka"'
Publikováno v:
IEEJ Transactions on Power and Energy. 136:192-197
Autor:
Naoaki Inoue, Hiromi Koga, Masahiro Arioka, Takakazu Harada, Satoru Yoshida, Shinichi Miki, Toshie Takeuchi, Akihiko Maruyama, Tadahiro Yoshida, Shinji Sato
Publikováno v:
Electrical Engineering in Japan. 175:18-24
A new 72-kV rated low-pressure dry-air insulated switchgear applying electromagnetic actuation and a function that supports CBM has been developed. First, the dielectric characteristics in dry air under lightning impulse application were investigated
Autor:
Tadahiro Yoshida, Hiromi Koga, Naoaki Inoue, Satoru Yoshida, Shinichi Miki, Toshie Takeuchi, Shinji Sato, Masahiro Arioka, Takakazu Harada, Akihiko Maruyama
Publikováno v:
IEEJ Transactions on Power and Energy. 128:1439-1444
A new 72kV rated low pressured dry air insulated switchgear applying electromagnetic actuation and function that supports CBM has been developed. First, dielectric characteristics in dry air under lightning impulse application has been investigated a
Autor:
Masahiro Arioka, Toshie Takeuchi, Toshihiro Matsunaga, Akihiko Maruyama, Kazushi Haruna, Tomotaka Yano, Mitsuru Tsukima, Kazuaki Imamura, Osamu Takahara, Taehyun Kim
Publikováno v:
IEEJ Transactions on Power and Energy. 128:1459-1464
A new electromagnetically actuated vacuum circuit breaker (VCB) has been developed for a 72kV rated switchgear. Each phase of this VCB has a plurality of compact electromagnetic actuators linked mechanically providing the required driving energy. The
Autor:
Tomotaka Yano, Naoaki Inoue, Tadahiro Yoshida, Toshie Takeuchi, Shinji Sato, Nobumoto Tohya, Masahiro Arioka
Publikováno v:
IEEJ Transactions on Power and Energy. 126:359-364
We have developed a new environmentally fitted 24kV cubicle-type gas insulated switchgear (C-GIS) applying our dry air insulation technology and the electromagnetic actuation technology. Firstly, we clarified the relationship between the breakdown fi
Publikováno v:
IEEJ Transactions on Power and Energy. 124:1132-1138
Publikováno v:
2008 International Conference on Condition Monitoring and Diagnosis.
Partial discharge (PD) monitoring system for cubicle type gas-insulated switchgear (C-GIS) filled with compressed dry air as an insulation gas was developed. The shield electrodes embedded in the solid insulator of bushings are used as PD sensors. Fo