Zobrazeno 1 - 10
of 20
pro vyhledávání: '"Martin Seipp"'
Autor:
Jennifer Herzog-Niescery, Thomas Steffens, Martin Bellgardt, Andreas Breuer-Kaiser, Philipp Gude, Heike Vogelsang, Thomas Peter Weber, Hans-Martin Seipp
Publikováno v:
BMC Anesthesiology, Vol 19, Iss 1, Pp 1-8 (2019)
Abstract Background Real-time photoacoustic gas monitoring is used for personnel exposure and environmental monitoring, but its accuracy varies when organic solvents such as alcohol contaminate measurements. This is problematic for anesthetic gas mea
Externí odkaz:
https://doaj.org/article/638f1f62a7634f5c849aeeb05550df1e
Autor:
Hans-Martin Seipp, Thomas Steffens
Publikováno v:
Lärmbekämpfung. 16:74-81
Für den Lernerfolg der Schüler/-innen und die gesundheitsverträglichen Arbeitsbedingungen der Lehrkräfte im Unterricht existieren hohe akustische Anforderungen, wobei Schall aus Raumlufttechnischen Anlagen (RLT-Anlagen) auf ≤ 35 dB(A) begrenzt
Autor:
Thomas Steffens, Hans-Martin Seipp
Publikováno v:
Gefahrstoffe. 81:135-146
Entgegen den realen Bedingungen basierten die bisherigen Bewertungsverfahren zu mobilen Luftreinigern (MLR) auf dem sofortigen Abbau hoher Partikelkonzentrationen aus homogener Verteilung. Auch wurden wirkungsmindernde Parameter sowie die Bilanzierun
Autor:
Thomas Steffens, Hans-Martin Seipp
Publikováno v:
Gefahrstoffe. 81:127-134
Für den Lernerfolg der Schüler/-innen und die gesundheitsverträglichen Arbeitsbedingungen der Lehrkräfte im Unterricht existieren hohe akustische Anforderungen, wobei Schall aus Raumlufttechnischen Anlagen (RLT-Anlagen) auf ≤ 35 dB(A) begrenzt
Autor:
Robert S. McLeod, Christina J. Hopfe, Eberhard Bodenschatz, Heinz‐Jörn Moriske, Ulrich Pöschl, Tunga Salthammer, Joachim Curtius, Frank Helleis, Jennifer Niessner, Caroline Herr, Thomas Klimach, Martin Seipp, Thomas Steffens, Christian Witt, Stefan N. Willich
Publikováno v:
Indoor Air
Implications for the academic and interpersonal development of children and adolescents underpin a global political consensus to maintain in-classroom teaching during the ongoing COVID-19 pandemic. In support of this aim, the WHO and UNICEF have call
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::baa3486ab49f4e6456239f7368004ad0
https://hdl.handle.net/21.11116/0000-000D-3EC8-D
https://hdl.handle.net/21.11116/0000-000D-3EC8-D
Autor:
Martin Bellgardt, Jennifer Herzog-Niescery, Thomas Weber, Waldemar Uhl, Philipp Gude, Hans-Martin Seipp, Orlin Belyaev, Torsten Herzog, Heike Vogelsang
Publikováno v:
Anesthesia & Analgesia. 131:537-543
BACKGROUND Studies demonstrated that operating room personnel are exposed to anesthetic gases such as sevoflurane (SEVO). Measuring the gas burden is essential to assess the exposure objectively. Air pollution measurements and the biological monitori
Autor:
Andreas Maier-Hasselmann, Horst Bartz, Hans-Martin Seipp, Philipp Gude, Thomas Weber, Martin Bellgardt, Jennifer Herzog-Niescery, Jörg Bunse, Heike Vogelsang
Publikováno v:
Journal of Occupational and Environmental Hygiene. 16:294-301
International guidelines recommend the use of ventilation systems in operating rooms to reduce the concentration of potentially hazardous substances such as anesthetic gases. The exhaust air grilles of these systems are typically located in the lower
Autor:
Hans-Martin Seipp, Michael Wild, Jochen Sticher, Andreas Maier-Hasselmann, Jan Esters, Thomas Steffens, Katja Birnstein, Mareike Ziegler, Jennifer Herzog-Niescery
Publikováno v:
Journal of Building Engineering. 52:104423
Autor:
Jennifer Herzog-Niescery, Hans-Martin Seipp, Armin Lahmer, Thomas Steffens, Janine Weigold, Torsten Herzog, Andreas Maier-Hasselmann
Publikováno v:
Journal of Occupational and Environmental Hygiene. 15:773-781
Surgical smoke resulting from electrocauterization is a health risk for operating room personnel. The U.S. National Institute for Occupational Safety and Health recommends the use of local exhaust ventilation such as a portable smoke evacuation syste
Autor:
Heike Vogelsang, Thomas Weber, Hans-Martin Seipp, Martin Bellgardt, Jennifer Herzog-Niescery, Waldemar Uhl, Philipp Gude
Publikováno v:
Acta Anaesthesiologica Scandinavica. 63:86-92
Background MIRUS™ is a device for target-controlled inhalational sedation in the ICU in combination with use of isoflurane, or sevoflurane, or desflurane. The feasibility of this device has recently been proven; however, ICU staff exposure may rest