Zobrazeno 1 - 6
of 6
pro vyhledávání: '"Martin P. Clouthier"'
Publikováno v:
Journal of Loss Prevention in the Process Industries. 57:120-130
An investigation into the limiting oxygen concentration (LOC) of fifteen combustible dusts and methane, ethanol and isopropanol hybrid mixtures in the standard 20 L explosion chamber was performed. Three ignition energies (10 J, 2 kJ and 10 kJ) were
Publikováno v:
Methods in Chemical Process Safety ISBN: 9780128175507
The purpose of the current chapter is to provide a general introduction to the field of dust explosions. Definitions of the most commonly used explosibility parameters are given and the five components of the explosion pentagon are named. The organiz
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::f2629761e03ef51fd6a3a0332766f2e7
https://doi.org/10.1016/bs.mcps.2019.03.004
https://doi.org/10.1016/bs.mcps.2019.03.004
Publikováno v:
Methods in Chemical Process Safety ISBN: 9780128175507
Loss practitioners in the process industries have developed a suite of safety measures to prevent the occurrence of dust explosions, or to mitigate the potential consequences. This chapter provides an overview of the protection methodologies that are
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::fcd5764c825a628731ace4e9a5f8167d
https://doi.org/10.1016/bs.mcps.2019.05.001
https://doi.org/10.1016/bs.mcps.2019.05.001
Autor:
Paul Amyotte, Damilare Ogungbemide, Chris Cloney, Robert C. Ripley, Robert Zalosh, Martin P. Clouthier
Publikováno v:
Journal of Loss Prevention in the Process Industries. 70:104398
Pressure piling presents a major explosion hazard in interconnected process vessels. Pressure enhancement in the secondary vessel due to the acceleration of the flame through the connecting pipe can generate a disproportionately more violent explosio
Publikováno v:
Process Safety Progress. 35:107-114
This article discusses technical and practical aspects of the limiting oxygen concentration (LOC) including a detailed appraisal of possible sources of measurement error. LOC values obtained in the “classical” 5-cm diameter, vertical tube apparat
Autor:
Luke S. Morrison, Jérôme Taveau, Martin P. Clouthier, Robert C. Ripley, Paul R. Amyotte, Ashok G. Dastidar, Robert Zalosh, Faisal Khan
Publikováno v:
Journal of Loss Prevention in the Process Industries. 62:103927
Metallic dusts with low values for maximum pressure P max and volume-normalized maximum rate of pressure rise K St as determined in bench-scale apparatus have been labeled as “marginally explosible.” These dusts pose unique challenges because the