Zobrazeno 1 - 10
of 12
pro vyhledávání: '"Martin Nirschl"'
Publikováno v:
Biosensors, Vol 1, Iss 4, Pp 164-176 (2011)
Film bulk acoustic resonators (FBAR) are mass sensitive, label-free biosensors that allow monitoring of the interaction between biomolecules. In this paper we use the FBAR to measure the binding of calcium and the CaMKII peptide to calmodulin. Becaus
Externí odkaz:
https://doaj.org/article/63603c4b789048b6812c1aa6eee1b55f
Publikováno v:
Biosensors, Vol 1, Iss 3, Pp 70-92 (2011)
Label-free biomolecular interaction analysis is an important technique to study the chemical binding between e.g., protein and protein or protein and small molecule in real-time. The parameters obtained with this technique, such as the affinity, are
Externí odkaz:
https://doaj.org/article/4238e542be8149f9a95d4947fdd67fe0
Autor:
Matthias Schreiter, Inger Vikholm-Lundin, Dana Pitzer, Ann-Charlotte Hellgren, Sanna Auer, Kari Tukkiniemi, Arto Rantala, Martin Nirschl
Publikováno v:
Sensors, Vol 10, Iss 5, Pp 4180-4193 (2010)
The throughput is an important parameter for label-free biosensors. Acoustic resonators like the quartz crystal microbalance have a low throughput because the number of sensors which can be used at the same time is limited. Here we present an array o
Externí odkaz:
https://doaj.org/article/2432fa5cf63e4b7488c75601e34a5460
Publikováno v:
Micro and Nanosystemse. 4:111-117
Thin-film bulk acoustic resonators (FBAR) can be used as mass sensors when the adsorbed mass is linear to the frequency shift caused by the adsorption. This is, however, only the case if the adsorbed layer is thin compared to the thickness of the res
Publikováno v:
Sensors and Actuators A: Physical. 165:415-421
Unlike the quartz crystal microbalance, which has been used extensively for the analysis of biochemical interactions, only few measurements with biochemical adsorbent have been done with film bulk acoustic resonators (FBAR). In this paper, the FBAR b
Publikováno v:
Auer, S, Nirschl, M, Schreiter, M & Vikholm-Lundin, I 2011, ' Detection of DNA hybridisation in a diluted serum matrix by surface plasmon resonance and film bulk acoustic resonators ', Analytical and Bioanalytical Chemistry, vol. 400, no. 5, pp. 1387-1396 . https://doi.org/10.1007/s00216-011-4871-0
Nanomolar quantities of single-stranded DNA products ∼100 nucleotides long can be detected in diluted 1% serum by surface plasmon resonance (SPR) and film bulk acoustic resonators (FBARs). We have used a novel FBAR sensor in parallel with SPR and o
Autor:
Dimitris Kyprianou, Sreenath Subrahmanyam, Martin Nirschl, Sergey A. Piletsky, Antonio Guerreiro, Anthony Turner, Iva Chianella
Publikováno v:
Biosensors and Bioelectronics. 25:1049-1055
The immobilisation of bio-receptors on transducer surfaces is a key step in the development of biosensors. The immobilisation needs to be fast, cheap and most importantly should not affect the biorecognition activity of the immobilised receptor. The
Autor:
Sanna Auer, Dana Pitzer, Inger Vikholm-Lundin, Ann-Charlotte Hellgren, Kari Tukkiniemi, Martin Nirschl, Matthias Schreiter, Arto Rantala
Publikováno v:
Sensors, 10 (5)
Sensors
Volume 10
Issue 5
Pages: 4180-4193
Nirschl, M, Rantala, A, Tukkiniemi, K, Auer, S, Hellgren, A-C, Pitzer, D, Schreiter, M & Vikholm-Lundin, I 2010, ' CMOS-integrated film bulk acoustic resonators for label-free biosensing ', Sensors, vol. 10, no. 5, pp. 4180-4193 . https://doi.org/10.3390/s100504180
Sensors (Basel, Switzerland)
Sensors, Vol 10, Iss 5, Pp 4180-4193 (2010)
Sensors
Volume 10
Issue 5
Pages: 4180-4193
Nirschl, M, Rantala, A, Tukkiniemi, K, Auer, S, Hellgren, A-C, Pitzer, D, Schreiter, M & Vikholm-Lundin, I 2010, ' CMOS-integrated film bulk acoustic resonators for label-free biosensing ', Sensors, vol. 10, no. 5, pp. 4180-4193 . https://doi.org/10.3390/s100504180
Sensors (Basel, Switzerland)
Sensors, Vol 10, Iss 5, Pp 4180-4193 (2010)
The throughput is an important parameter for label-free biosensors. Acoustic resonators like the quartz crystal microbalance have a low throughput because the number of sensors which can be used at the same time is limited. Here we present an array o
Autor:
Christiane Erler, Wolfgang Pompe, Anja Blüher, Matthias Schreiter, Martin Nirschl, Beate Katzschner, Michael Mertig
Publikováno v:
2009 IEEE Sensors.
We report investigations on the adsorption and in-vitro recrystallization kinetics of the bacterial surface layer protein of Bacillus sphaericus NCTC 9602 on gold surfaces by means of film bulk acoustic resonators. The acoustic resonators were operat
Autor:
Beate Katzschner, Janos Vörös, Inger Vikholm-Lundin, Michael Mertig, Anja Blüher, Matthias Schreiter, Wolfgang Pompe, Christiane Erler, Sanna Auer, Martin Nirschl
Publikováno v:
Nirschl, M, Blüher, A, Erler, C, Katzschner, B, Vikholm-Lundin, I, Auer, S, Vörös, J, Pompe, W, Schreiter, M & Mertig, M 2009, ' Film bulk acoustic resonators for DNA and protein detection and investigation of in vitro bacterial S-layer formation ', Sensors and Actuators A: Physical, vol. 156, no. 1, pp. 180-184 . https://doi.org/10.1016/j.sna.2009.02.021
We report investigations on the use of film bulk acoustic resonators for the label-free, multiplexed biosensing of DNA and proteins. The used acoustic resonators were operated in shear mode at about 800 MHz. From the measured changes of frequency and
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5b829b6bbaf8bec7a21600998eaffed3
https://cris.vtt.fi/en/publications/6cac8dea-fb56-4676-b47e-49bdf2e3a90f
https://cris.vtt.fi/en/publications/6cac8dea-fb56-4676-b47e-49bdf2e3a90f