Zobrazeno 1 - 10
of 51
pro vyhledávání: '"Martin Kronschläger"'
Autor:
Martin Kronschläger, Alessandro Ruzza, Johannes Zeilinger, Andreas Schlatter, Manuel Ruiss, Oliver Findl
Publikováno v:
BMC Ophthalmology, Vol 24, Iss 1, Pp 1-7 (2024)
Abstract Background To compare the difference in rebubbling rates between patients undergoing Descemet membrane endothelial keratoplasty (DMEK) with endothelium-in using a standard IOL cartridge and those with endothelium-out DMEK utilizing a no-touc
Externí odkaz:
https://doaj.org/article/bec6f49f1186419080235d1cd7780dfd
Autor:
Oliver Findl, Martin Kronschläger, Manuel Ruiss, Johannes Zeilinger, Andreas Schlatter, Natascha Bayer
Publikováno v:
BMJ Open Ophthalmology, Vol 9, Iss 1 (2024)
Purpose To compare the two most used digital alignment systems regarding precision, repeatability and loss of track.Methods 15 eyes of 15 patients older than 21 years with cataracts were included in this prospective study. The two systems were intrao
Externí odkaz:
https://doaj.org/article/37233a56aaf740888ac834fe3a5f0f0e
Autor:
Spela Stunf Pukl, Martin Kronschläger, Manuel Ruiss, Stéphane Blouin, Emre Rüştü Akcan, Oliver Findl
Publikováno v:
BMC Ophthalmology, Vol 24, Iss 1, Pp 1-9 (2024)
Abstract Purpose To measure the dislocation forces in relation to haptic material, flange size and needle used. Setting Hanusch Hospital, Vienna, Austria. Design Laboratory Investigation. Methods, main outcome measures 30 G (gauge) thin wall and 27 G
Externí odkaz:
https://doaj.org/article/0fb3d5adf7044a80a8bc7ab2022ea08d
Publikováno v:
Scientific Reports, Vol 11, Iss 1, Pp 1-11 (2021)
Abstract At the moment, cataract, which is the opacification of the eye’s lens, can only be treated by surgery. In order to develop and test new pharmacological treatment strategies for the disease, there is a need for an appropriate in vitro model
Externí odkaz:
https://doaj.org/article/1b87215b956f482197e15195553cc332
Autor:
Pearse A Keane, Josef Huemer, Oliver Findl, Dawn Sim, Siegfried K Wagner, Martin Kronschläger, Manuel Ruiss
Publikováno v:
BMJ Open Ophthalmology, Vol 7, Iss 1 (2022)
Objective To train and validate a code-free deep learning system (CFDLS) on classifying high-resolution digital retroillumination images of posterior capsule opacification (PCO) and to discriminate between clinically significant and non-significant P
Externí odkaz:
https://doaj.org/article/43aed0db62294952af1c7c0fabcd5f8c
Publikováno v:
BMC Ophthalmology, Vol 21, Iss 1, Pp 1-7 (2021)
Abstract Background Remnant interface fluid following Descemet stripping automated endothelial keratoplasty (DSAEK) is associated with postoperative detachments. The aim of this study was to assess outcomes of intraoperative optical coherence tomogra
Externí odkaz:
https://doaj.org/article/8b88adec169a40b5b0193c0c843dfb97
Autor:
Martin Kronschläger, Hannes Siegl, Axel Pinz, Christoph Feichtenhofer, Wolf Buehl, Nino Hirnschall, Oliver Findl
Publikováno v:
BMC Ophthalmology, Vol 19, Iss 1, Pp 1-7 (2019)
Abstract Background The present study aims to investigate an automated qualitative and quantitative assessment system (Automated Quantification of After-Cataract [AQUA II]) of posterior capsule opacification (PCO) in high-resolution digital retroillu
Externí odkaz:
https://doaj.org/article/d11b71e05d01400d81441ac3c3f8f8cd
Publikováno v:
PLoS ONE, Vol 9, Iss 9, p e106926 (2014)
PURPOSE: To introduce a model for the time evolution of active caspase-3 protein expression in albino rat lens up to 24 hours after in vivo exposure to low dose UVR in the 300 nm wavelength region (UVR-300 nm). METHODS: Forty Sprague-Dawley rats were
Externí odkaz:
https://doaj.org/article/475b179851534d8c89d7ad693ad8ebc4
Publikováno v:
Journal of Cataract and Refractive Surgery. 48:1342-1345
A technique for achieving an optimal flange size with 5-0 polypropylene and 6-0 polypropylene used for flanged intrascleral intraocular lens fixation is described. Flange size in polypropylene sutures is dependent on heating length and independent of
Publikováno v:
Journal of Cataract and Refractive Surgery.