Zobrazeno 1 - 10
of 11
pro vyhledávání: '"Martin J. Petrak"'
Autor:
Sara Parashin, Jeff Leiter, Trevor C. Gascoyne, Sheila McRae, Eric Bohm, Martin J. Petrak, Peter B. MacDonald
Publikováno v:
Canadian Journal of Surgery. 60:273-279
This study aimed to assess differences in the fixation and functional outcomes between pegged and keeled all-polyethylene glenoid components for standard total shoulder arthroplasty.Patients were randomized to receive a keeled or pegged all-polyethyl
Publikováno v:
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 230:1141-1147
Failure analysis was performed for two humeral tray components which fractured in vivo after only 6 and 9 months. Implant retrieval analysis indicated that the components failed due to fatigue failure initiating from a small radius fillet at the inte
Publikováno v:
Acta Orthopaedica. 85:470-473
Background and purpose — We previously reported on a randomized controlled trial (RCT) that examined the effect of adding tobramycin to bone cement after femoral stem migration. The present study examined femoral head penetration into both conventi
Publikováno v:
Journal of Biomechanics. 47:1127-1133
The cost and time efficiency of computational polyethylene wear simulations may enable the optimization of total knee replacements for the reduction of polyethylene wear. The present study proposes an energy dissipation wear model for polyethylene wh
Publikováno v:
Tribology International. 59:284-291
A computational model to predict polyethylene wear in modular total knee replacements was developed. The results from knee simulator wear tests were implemented with finite element simulations to identify the wear factors of Archard's wear law. The c
Publikováno v:
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 226:235-245
The micromotion at the interface between the polyethylene tibial insert and metal tibial tray [corrected] in modular total knee replacements [corrected] has been shown to contribute to wear particle-induced osteolysis and may [corrected] cause implan
Autor:
Eric Bohm, Craig J. Della Valle, Allan E. Gross, Bassam A. Masri, Clive P. Duncan, Donald S. Garbuz, Martin J. Petrak, Nelson V. Greidanus
Publikováno v:
Clinical Orthopaedics & Related Research. 470:351-356
Dislocation after revision THA is a common complication. Large heads have the potential to decrease dislocation rate, but it is unclear whether they do so in revision THA.We therefore determined whether a large femoral head (36 and 40 mm) resulted in
Publikováno v:
Evidence-Based Orthopedics
Autor:
Urs P. Wyss, S.F. Koval, Martin J. Petrak, Eric Bohm, Leah E Guenther, Jan-M Brandt, Alex Vecherya
Publikováno v:
Journal of the mechanical behavior of biomedical materials. 34
The wear performance of two types of crosslinked polyethylene (Marathon™ and XLK™, DePuy Synthes Inc., Warsaw, IN) was evaluated in a pin-on-disc wear tester, a hip wear simulator, and a knee wear simulator. Sodium azide was used as the microbial
Autor:
Peter B. MacDonald, Martin J. Petrak, Jeff Leiter, Trevor C. Gascoyne, Eric Bohm, Sheila McRae
Publikováno v:
Journal of Shoulder and Elbow Surgery. 23:e239-e240