Zobrazeno 1 - 10
of 134
pro vyhledávání: '"Martin, Bues"'
Autor:
Yixiu Kang, Martin Bues, Michele Y. Halyard, Lisa A. McGee, Tamara Z. Vern-Gross, William W. Wong, Sameer R. Keole, Carlos Vargas, Sarah E. James, Safia K. Ahmed, James P. Archuleta, Ana K. Ridgway, Pedro R. Lara, Mirek Fatyga
Publikováno v:
Radiation Oncology, Vol 18, Iss 1, Pp 1-12 (2023)
Abstract Background Setup reproducibility of the tissue in the proton beam path is critical in maintaining the planned clinical target volume (CTV) dose coverage and sparing the organs at risk (OAR). In this study, we retrospectively evaluated radiat
Externí odkaz:
https://doaj.org/article/16a1a70df53442b288a88bd38a15c166
Autor:
Jason Holmes, Jiajian Shen, Samir H. Patel, William W. Wong, Robert L. Foote, Martin Bues, Wei Liu
Publikováno v:
Frontiers in Oncology, Vol 12 (2022)
The purpose of this work is to investigate collimating individual proton beamlets from a dosimetric perspective and to introduce a new device concept, the spot scanning aperture (SSA). The SSA consists of a thin aperture with a small cylindrical open
Externí odkaz:
https://doaj.org/article/fb14e05e4a4e4f84a36f7b996f91ca23
Publikováno v:
Frontiers in Oncology, Vol 12 (2022)
PurposeTo investigate the beam delivery time (BDT) reduction due to the improvement of machine parameters for Hitachi synchrotron-based proton PBS system.MethodsBDTs for representative treatment plans were calculated to quantitatively estimate the BD
Externí odkaz:
https://doaj.org/article/0c7a0af6ecb54dce84dbe06d136e8055
Autor:
Wei Deng, PhD, Yunze Yang, PhD, Chenbin Liu, PhD, Martin Bues, PhD, Radhe Mohan, PhD, William W. Wong, MD, Robert H. Foote, MD, Samir H. Patel, MD, Wei Liu, PhD
Publikováno v:
International Journal of Particle Therapy, Vol 8, Iss 1, Pp 36-49 (2021)
In this review article, we review the 3 important aspects of linear-energy-transfer (LET) in intensity-modulated proton therapy (IMPT) for head and neck (H&N) cancer management. Accurate LET calculation methods are essential for LET-guided plan evalu
Externí odkaz:
https://doaj.org/article/4bb1f2dba61547a7baf46c0001ead745
Autor:
Daniel E. Hyer, PhD, Laura C. Bennett, MS, Theodore J. Geoghegan, MS, Martin Bues, PhD, Blake R. Smith, PhD
Publikováno v:
International Journal of Particle Therapy, Vol 8, Iss 1, Pp 73-83 (2021)
Purpose: The development of collimating technologies has become a recent focus in pencil beam scanning (PBS) proton therapy to improve the target conformity and healthy tissue sparing through field-specific or energy-layer–specific collimation. Giv
Externí odkaz:
https://doaj.org/article/f79a369b70b54b7ba809b0c52f90b0a6
Autor:
Yunze Yang, Olivia M. Muller, Satomi Shiraishi, Matthew Harper, Adam C. Amundson, William W. Wong, Lisa A. McGee, Jean-Claude M. Rwigema, Steven E. Schild, Martin Bues, Mirek Fatyga, Justin D. Anderson, Samir H. Patel, Robert L. Foote, Wei Liu
Publikováno v:
Frontiers in Oncology, Vol 12 (2022)
PurposeTo retrospectively investigate empirical relative biological effectiveness (RBE) for mandible osteoradionecrosis (ORN) in head and neck (H&N) cancer patients treated with pencil-beam-scanning proton therapy (PBSPT).MethodsWe included 1,266 H&N
Externí odkaz:
https://doaj.org/article/d136e7ee70b249a7a268197caf6ea8c8
Autor:
Yixiu Kang, Jiajian Shen, Wei Liu, Paige A. Taylor, Hunter S. Mehrens, Xiaoning Ding, Yanle Hu, Erik Tryggestad, Sameer R. Keole, Steven E. Schild, William W. Wong, Mirek Fatyga, Martin Bues
Publikováno v:
Radiation Oncology, Vol 14, Iss 1, Pp 1-10 (2019)
Abstract Purpose The purpose of this study is to evaluate the impact of two methods of reporting planned dose distributions on the Gamma analysis pass rates for comparison with measured 2D film dose and simulated delivered 3D dose for proton pencil b
Externí odkaz:
https://doaj.org/article/3cb770aaca5a4144b5281c65caa027da
Autor:
Joshua Stoker, Sujay Vora, Ameet Patel, David Grosshans, Paul D. Brown, Tamara Vern-Gross, Martin Bues, Thomas Daniels, Bryce Allred, Arielle Uejo, Heidi Kosiorek, Marlene Bruso, Sameer Keole
Publikováno v:
Physics and Imaging in Radiation Oncology, Vol 8, Iss , Pp 28-32 (2018)
Background and purpose: Intensity modulated proton therapy (IMPT) allows for modulation parameterized for individual beamlets by position, intensity, and depth. This modulation capability is ideally suited for sparing organs at risk intermediate of t
Externí odkaz:
https://doaj.org/article/6f60771914c14aaeaecf5f6e60f84bec
Autor:
James E. Younkin, PhD, Martin Bues, PhD, Terence T. Sio, MD, Wei Liu, PhD, Xiaoning Ding, PhD, Sameer R. Keole, MD, Joshua B. Stoker, PhD, Jiajian Shen, PhD
Publikováno v:
Advances in Radiation Oncology, Vol 3, Iss 3, Pp 412-420 (2018)
Purpose: Multiple energy extraction (MEE) is a technology that was recently introduced by Hitachi for its spot-scanning proton treatment system, which allows multiple energies to be delivered in a single synchrotron spill. The purpose of this paper i
Externí odkaz:
https://doaj.org/article/04c601aaf91f4999815d28f8c288deb4
Autor:
Yunze Yang, Jean‐Claude M. Rwigema, Carlos Vargas, Nathan Y. Yu, Sameer R. Keole, William W. Wong, Steven E. Schild, Martin Bues, Wei Liu, Jiajian Shen
Publikováno v:
Medical Physics. 49:7428-7437