Zobrazeno 1 - 10
of 32
pro vyhledávání: '"Markus Sticker"'
Publikováno v:
Microscopy Today. 28:36-43
Today, researchers have a number of powerful image processing methods at hand that have the potential to make comparably simple and inexpensive widefield microscope systems more powerful and versatile. These techniques can enable new insights into bi
Publikováno v:
Applied optics. 57(7)
Fourier ptychographic microscopy (FPM) is a recently proposed computational imaging method that achieves both high resolution (HR) and wide field of view. In the conventional FPM model, the sample is assumed to be a 2D thin layer, and a series of low
Autor:
Stefan Pieh, Richard Zöhrer, Markus Sticker, Birgit Lackner, Herbert Weghaupt, Christian Skorpik, Georg Hanselmayer, Adolf Friedrich Fercher
Publikováno v:
British Journal of Ophthalmology. 85:816-821
AIMS To calculate the diameter of halos perceived by patients with multifocal intraocular lenses (IOLs) and to stimulate halos in patients with refractive multifocal IOLs in a clinical experiment. METHODS Calculations were done to show the diameter o
Autor:
S. Molebny, Christoph K. Hitzenberger, Harald Sattmann, Wolfgang Drexler, Adolf Friedrich Fercher, Franz Lexer, Markus Sticker
Publikováno v:
Journal of Modern Optics. 46:541-553
We present a new OCT technique which renders the transversal resolution depth independent. This is achieved by an optical setup which shifts the focus of the beam illuminating the object through the object depth without changing the path length in th
Autor:
Adolf Friedrich Fercher, Michael Pircher, Christoph K. Hitzenberger, Markus Sticker, Erich Goetzinger
Publikováno v:
Optics express. 9(13)
We present an improved method of polarization sensitive optical coherence tomography that enables measurement and imaging of backscattered intensity, birefringence, and fast optic axis orientation simultaneously with only one single A-scan per transv
Autor:
Adolf Friedrich Fercher, Markus Sticker, Christoph K. Hitzenberger, Andrzej Kowalczyk, Rainer A. Leitgeb, Maciej Wojtkowski
Publikováno v:
Scopus-Elsevier
A new method of measurement that essentially combines Fourier-domain optical coherence tomography with spectroscopy is introduced. By use of a windowed Fourier transform it is possible to obtain, in addition to the object structure, spectroscopic inf
Autor:
Marcus Blum, Walter Sekundo, Kathleen S. Kunert, Christoph Russmann, Markus Sticker, Annika Gille, Wilfried Bissmann, Mark Bischoff, Gregor Stobrawa
Publikováno v:
Journal of cataract and refractive surgery. 34(9)
Purpose To prospectively study the feasibility of femtosecond lenticule extraction (FLE), a new method of refractive correction. Setting Department of Ophthalmology, Philipps University of Marburg and Helios Clinic, Erfurt, Germany. Methods A flap an
Autor:
Irene Dejaco-Ruhsmann, Markus Sticker, Adolf Friedrich Fercher, Erich Goetzinger, S. Kaminski, Michael Pircher, Oliver Findl, Christoph K. Hitzenberger, Christian Skorpik
Publikováno v:
SPIE Proceedings.
Polarization sensitive optical coherence tomography (PS-OCT) is a functional extension of optical coherence tomography (OCT). We used phase resolved PS-OCT to measure and image three dimensional birefringent properties of pathologic and non pathologi
Autor:
Irene Dejaco-Ruhswurm, S. Kaminski, Michael Pircher, Adolf Friedrich Fercher, Christoph K. Hitzenberger, Christian Skorpik, Erich Götzinger, Markus Sticker
Publikováno v:
SPIE Proceedings.
Polarization sensitive optical coherence tomography (PS-OCT) was used to measure and image retardation and birefringent axis orientation of in vitro human cornea. We used a two-channel PS-OCT system employing a phse sensitive recording of the interfe
Autor:
Adolf Friedrich Fercher, Harald Sattmann, Michael Pircher, Christoph K. Hitzenberger, Erich Götzinger, Markus Sticker
Publikováno v:
SPIE Proceedings.
Optical coherence tomography (OCT) measures and images the backscattering potential of transparent and semi-transparent samples. Recently, we reported on an extension of OCT with a differential phase contrast (DPC) technique. We have improved the tec