Zobrazeno 1 - 10
of 92
pro vyhledávání: '"Markus, Stoeckli"'
Autor:
Markus Stoeckli, Han Wang, Dieter Staab, Frederic Grandjean, Fabian Sesterhenn, Christian Opitz
Publikováno v:
SLAS Technology, Vol 29, Iss 6, Pp 100216- (2024)
Tracking chemical reactions by measuring incurred mass shifts upon successful binding is a direct and attractive alternative to existing assays based on chemical tags. Traditional methods use liquid chromatography-mass spectrometry (LC-MS), and becau
Externí odkaz:
https://doaj.org/article/6b9a61c0727044d1b88808c950235e50
Autor:
Diethilde Theil, Paul Smith, Catherine Huck, Yoann Gilbart, Algirdas Kakarieka, David Leppert, Celine Rauld, Cindy Schmid, Reto Baumgartner, Nathalie Stuber, Francisco Cordoba, Valerie Dubost, Katy Darribat, Magali Jivkov, Wilfried Frieauff, Rainer Kneuer, Markus Stoeckli, Stefan Reinker, Keith Mansfield, José M. Carballido, Philippe Couttet, Gisbert Weckbecker
Publikováno v:
Frontiers in Immunology, Vol 10 (2019)
Ofatumumab is the first, fully human, anti-CD20 monoclonal antibody in Phase 3 development for multiple sclerosis (MS). The study focused on changes in lymphocyte subsets in blood and lymphoid tissues and on potential novel biomarkers as a result of
Externí odkaz:
https://doaj.org/article/ba3d555b05114fb2a5dab3fbd7970781
Autor:
Ernst Freund, Dan Huynh, Richard A. Lewis, Eric J. Ma, Markus Stoeckli, Elke Koch, Holger Schlingensiepen, Markus Vogel, Mathieu Ligibel, Radka Snajdrova, Charles Moore, Elina Maria Siirola, Luca Siegrist, Caroline Bouquet, Michael Faller, Edward J. Oakeley, Geoffrey Cutler, Anne-Christine Acker, Fabian K. Eggimann, Arkadij Kummer
Publikováno v:
ACS Catalysis. 11:12433-12445
Publikováno v:
CHIMIA, Vol 68, Iss 3 (2014)
A device was built for matrix deposition in mass spectrometric imaging. This spray-type instrument requires no user interaction other than providing the spray solution and selecting the pre-defined or custom-built method. Robustness was achieved by u
Externí odkaz:
https://doaj.org/article/9fb69046b11b4b89a99224e0c9a55624
Publikováno v:
CHIMIA, Vol 67, Iss 4 (2013)
Externí odkaz:
https://doaj.org/article/2a99630d97534a8e98f1d1fa486dcac9
Autor:
Catherine Huck, Francisco Cordoba, Markus Stoeckli, Rainer Kneuer, Keith Mansfield, Katy Darribat, Philippe Couttet, José M. Carballido, Yoann Gilbart, Paul Smith, Cindy Schmid, Celine Rauld, Wilfried Frieauff, Stefan Reinker, Reto Baumgartner, Valerie Dubost, Algirdas Kakarieka, Nathalie Stuber, Magali Jivkov, Gisbert Weckbecker, Diethilde Theil, David Leppert
Publikováno v:
Frontiers in Immunology
Frontiers in Immunology, Vol 10 (2019)
Frontiers in Immunology, Vol 10 (2019)
Ofatumumab is the first, fully human, anti-CD20 monoclonal antibody in Phase 3 development for multiple sclerosis (MS). The study focused on changes in lymphocyte subsets in blood and lymphoid tissues and on potential novel biomarkers as a result of
Autor:
Franck Picard, Thierry Wolf, Olivier Kretz, Walid Elbast, Christian Lanshoeft, Markus Walles, Markus Stoeckli, Gerhard Stutz
Publikováno v:
Rapid Communications in Mass Spectrometry. 30:823-832
Rationale Antibody–drug conjugates (ADCs) are some of the most promising antibody-related therapeutics. The fate of the cytotoxic moiety of ADCs in vivo after proteolytic degradation of the antibody needs to be well understood in order to mitigate
Autor:
Dieter Staab, Markus Stoeckli
Publikováno v:
Journal of the American Society for Mass Spectrometry. 26:911-914
The new open-source software and hardware matrix deposition device named iMatrixSpray was optimized and specified for homogeneity, reproducibility, and sensitivity in MS imaging experiments. The results confirm the design claims, with the device deli
Autor:
Benjamin Balluff, Markus Stoeckli, Liam A. McDonnell, Juan Pablo Albar, Ron M. A. Heeren, Garry L. Corthals, Andreas Römpp, Per E. Andrén, Axel Walch
Publikováno v:
Analytical and Bioanalytical Chemistry, 407(8), 2035-2045
Analytical and Bioanalytical Chemistry, 407(8), 2035-2045. Springer
Analytical and Bioanalytical Chemistry, 407(8), 2035-2045. Springer Verlag
Analytical and Bioanalytical Chemistry, 407(8), 2035-2045. Springer
Analytical and Bioanalytical Chemistry, 407(8), 2035-2045. Springer Verlag
IntroductionMass spectrometry imaging (MSI) uses biomolecular massspectrometry techniques to simultaneously record the distri-butions of molecules directly from tissue samples [1] andwithin their histological context [2]. MSI is now applied inincreas
Autor:
Ursula Junker, Brendan Prideaux, Markus Stoeckli, Douglas C. Bauer, Alex Odermatt, Stéphanie Boudon, Dieter Staab, Gregory Morandi
Publikováno v:
Journal of the American Society for Mass Spectrometry. 25:1803-1809
Mass spectrometry imaging (MSI) was applied to samples from mouse skin and from a human in vitro 3D skin model in order to assess its suitability in the context of photosafety evaluation. MSI proved to be a suitable method for the detection of the mo