Zobrazeno 1 - 10
of 14
pro vyhledávání: '"Marko Theodoor Blom"'
Autor:
Nadine Besse, Bas-Jan Hoogenberg, Robert Jan Boom, Bekir Aksoy, Marko Theodoor Blom, Herbert Shea
Publikováno v:
Lab on a Chip. 19:608-617
We report arrays of latching microfluidic valves based on shape memory polymers (SMPs), and show their applications as reagent mixers and as peristaltic pumps. The valve design takes advantage of the SMP's multiple stable shapes and over a hundred-fo
Autor:
R. Haverkate, Maciej Skolimowski, A. van den Berg, Marko Theodoor Blom, Anke Ricarda Vollertsen, Robert Jan Boom, B. A. M. Wesselink, S. Dekker, Robert Passier, A. D. van der Meer, Douwe de Boer, Mathieu Odijk, Hoon Suk Rho
Publikováno v:
Microsystems and Nanoengineering, 6(1):107. Nature Publishing Group
Microsystems & Nanoengineering, 6(1):107. Nature Publishing Group
Microsystems & Nanoengineering
Microsystems & Nanoengineering, 6(1):107. Nature Publishing Group
Microsystems & Nanoengineering
Microfluidic systems enable automated and highly parallelized cell culture with low volumes and defined liquid dosing. To achieve this, systems typically integrate all functions into a single, monolithic device as a "one size fits all" solution. Howe
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d3bc9235fabf4255e0a62e5937d73650
https://research.utwente.nl/en/publications/974d805a-ed74-4e93-ab92-4c53fe49d089
https://research.utwente.nl/en/publications/974d805a-ed74-4e93-ab92-4c53fe49d089
Autor:
A. Le Nel, W. Buesink, Marko Theodoor Blom, S. Dekker, Mathieu Odijk, Nicolas Verplanck, M. Alessio, C. Dehan, A. van den Berg, W. César, M. Hihoud
Publikováno v:
Sensors and Actuators B: Chemical
Sensors and Actuators B: Chemical, 2018, 272, pp.468-478. ⟨10.1016/j.snb.2018.04.005⟩
Sensors and Actuators B: Chemical, Elsevier, 2018, 272, pp.468-478. ⟨10.1016/j.snb.2018.04.005⟩
Sensors and actuators. B: Chemical, 272, 468-478. Elsevier
Sensors and Actuators B: Chemical, 2018, 272, pp.468-478. ⟨10.1016/j.snb.2018.04.005⟩
Sensors and Actuators B: Chemical, Elsevier, 2018, 272, pp.468-478. ⟨10.1016/j.snb.2018.04.005⟩
Sensors and actuators. B: Chemical, 272, 468-478. Elsevier
International audience; Since the Lab on a Chip concept was introduced in the 1990s, a lot of scientific advancements have occurred. However, large scale commercial realization of microfluidic technology is being prevented by the lack of standardizat
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::b01906fc75565cc91db243b49a5fd696
https://cea.hal.science/cea-02183835
https://cea.hal.science/cea-02183835
Autor:
Marko Theodoor Blom, Michael Curt Elwenspoek, E. Chmela, A. van den Berg, R. Tijssen, F. H.J. Van Der Heyden, R.E. Oosterbroek
Publikováno v:
Journal of microelectromechanical systems, 14(1), 70-80. IEEE
We present a micromachined differential viscosity detector suitable for integration into an on-chip hydrodynamic chromatography system. The general design, however, is applicable to any liquid chromatography system that is used for separation of poly
Autor:
Michael Curt Elwenspoek, A. van den Berg, R. Tijssen, F.H.J. van der Heyden, Marko Theodoor Blom, Johannes G.E. Gardeniers, E. Chmela
Publikováno v:
Sensors and Actuators. B, Chemical, 92, 102-109. Elsevier
Sensors and actuators. B: Chemical, 92(1-2), 102-109. Elsevier
Sensors and actuators. B: Chemical, 92(1-2), 102-109. Elsevier
A design is presented for a micromachined differential viscometer, that is suitable for integration into a planar hydrodynamic chromatography system (HDC) for polymer analysis. The viscometer consists of four equal flow restrictions and two pressure
Autor:
Mark Olde Riekerink, Marko Theodoor Blom, Hildebrand Tigelaar, Jeroen Haneveld, Ronny van 't Oever, Johannes Oonk, Peter Tijssen
Publikováno v:
SPIE Proceedings.
A novel method for laser assisted room temperature bonding of two substrates is presented. The method enables the packaging of delicate (bio)structures and/or finished (MEMS) devices, as there is no need for a high temperature annealing process. This
Autor:
Christian Poelma, Jerry Westerweel, Harald G. J. vanMil, Jonathan Chicken, Ronny van 't Oever, Abdulrahman Al-Afandi, Wilfred Buesink, Johannes Oonk, Elwin Xander Vrouwe, Eric M. Wielhouwer, Marinus Bernardus Olde Riekerink, Marko Theodoor Blom, Shaukat Ali, Michael K. Richardson
Publikováno v:
Lab on a chip. 11(10)
The zebrafish embryo is a small, cheap, whole-animal model which may replace rodents in some areas of research. Unfortunately, zebrafish embryos are commonly cultured in microtitre plates using cell-culture protocols with static buffer replacement. S
Autor:
A. van den Berg, R. Tijssen, Marko Theodoor Blom, F.H.J. van der Heyden, Michael Curt Elwenspoek, E. Chmela, R.E. Oosterbroek
Publikováno v:
Micro Total Analysis Systems 2002 ISBN: 9789401039536
A novel micromachined differential viscosity detector is presented that is suitable for integration with an on-chip hydrodynamic chromatography system. Viscosity detection is demonstrated using a prototype that shows a resolution in the specific visc
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::805ed6909e428cd388e4f7d13400d830
https://doi.org/10.1007/978-94-010-0504-3_13
https://doi.org/10.1007/978-94-010-0504-3_13
Publikováno v:
Lab on a chip, 2(4), 235-241. Royal Society of Chemistry
Lab on a Chip, 2, 235-241. Royal Society of Chemistry
Lab on a Chip, 2, 235-241. Royal Society of Chemistry
A pressure-actuated on-chip injection system has been developed that is compatible with shallow microchannels with a very large aspect ratio, i.e. 1 microm deep and up to 1000 microm wide. Such channels offer potential advantages in the miniaturisati
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::31c37bdab32fd813ee61d3afb87fe65c
https://research.utwente.nl/en/publications/b433ba91-5542-4c02-9f08-9c3d78325636
https://research.utwente.nl/en/publications/b433ba91-5542-4c02-9f08-9c3d78325636
Publikováno v:
Micro Total Analysis Systems 2001 ISBN: 9789401038935
Proceedings "Micro Total Analysis Systems Conference", 646-648
STARTPAGE=646;ENDPAGE=648;TITLE=Proceedings "Micro Total Analysis Systems Conference"
Proceedings "Micro Total Analysis Systems Conference", 646-648
STARTPAGE=646;ENDPAGE=648;TITLE=Proceedings "Micro Total Analysis Systems Conference"
Development of a novel on-chip HDC system for analytical separation of (bio)polymers and particles is presented, consisting of an extremely shallow separation channel with integrated injection, fabricated using silicon and glass microtechnology. Succ
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::67516e4698eb92d25dcb3b4d72845fc9
https://doi.org/10.1007/978-94-010-1015-3_284
https://doi.org/10.1007/978-94-010-1015-3_284