Zobrazeno 1 - 4
of 4
pro vyhledávání: '"Marjolein C. van der Meer"'
Autor:
Danique L.J. Barten, Bradley R. Pieters, Anton Bouter, Marjolein C. van der Meer, Stef C. Maree, Karel A. Hinnen, Henrike Westerveld, Peter A.N. Bosman, Tanja Alderliesten, Niek van Wieringen, Arjan Bel
Publikováno v:
Brachytherapy. Elsevier Inc.
Brachytherapy, 22(2), 279-289. Elsevier Inc.
Brachytherapy, 22(2), 279-289. Elsevier Inc.
Purpose: This prospective study evaluates our first clinical experiences with the novel ``BRachytherapy via artificial Intelligent GOMEA-Heuristic based Treatment planning'' (BRIGHT) applied to high-dose-rate prostate brachytherapy. MethodS AND MATER
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f2d51e6f3cbb7e35b6193343de6fd5d5
https://pure.amc.nl/en/publications/towards-artificial-intelligencebased-automated-treatment-planning-in-clinical-practice(63803e0f-b0f8-4ccf-a375-00b744c5820e).html
https://pure.amc.nl/en/publications/towards-artificial-intelligencebased-automated-treatment-planning-in-clinical-practice(63803e0f-b0f8-4ccf-a375-00b744c5820e).html
Autor:
Peter A. N. Bosman, Tanja Alderliesten, Yury Niatsetski, Bradley R. Pieters, Marjolein C. van der Meer, Arjan Bel
Publikováno v:
Physics in Medicine and Biology, 66(5)
Physics in medicine and biology, 66(5):055001. IOP Publishing Ltd.
Physics in Medicine and Biology, 66(5). IOP Publishing Ltd
Physics in medicine and biology, 66(5):055001. IOP Publishing Ltd.
Physics in Medicine and Biology, 66(5). IOP Publishing Ltd
Purpose. Recently, we introduced a bi-objective optimization approach based on dose-volume indices to automatically create clinically good HDR prostate brachytherapy plans. To calculate dose-volume indices, a reconstruction algorithm is used to deter
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::55d49439d9c9d2b6e93800dc4a18f5be
https://ir.cwi.nl/pub/30649
https://ir.cwi.nl/pub/30649
Autor:
Arjan Bel, Niek van Wieringen, Bradley R. Pieters, Marjolein C. van der Meer, Tanja Alderliesten, Yury Niatsetski, Peter A. N. Bosman
Publikováno v:
Medical Physics, 47(12), 6077-6086. WILEY
Medical Physics, 47(12), 6077-6086
Medical Physics
Medical physics, 47(12), 6077-6086. AAPM-American Association of Physicists in Medicine
Medical Physics, 47(12), 6077-6086
Medical Physics
Medical physics, 47(12), 6077-6086. AAPM-American Association of Physicists in Medicine
Purpose: Bi-objective simultaneous optimization of catheter positions and dwell times for high-dose-rate (HDR) prostate brachytherapy, based directly on dose-volume indices, has shown promising results. However, optimization with the state-of-the-art
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::4eced26f8adf2835e24eb706f67ff2bc
http://hdl.handle.net/1887/3278803
http://hdl.handle.net/1887/3278803
Autor:
Bradley R. Pieters, Marjolein C. van der Meer, Arjan Bel, Yury Niatsetski, Tanja Alderliesten, Peter A. N. Bosman, Niek van Wieringen
Publikováno v:
Journal of Applied Clinical Medical Physics
Journal of Applied Clinical Medical Physics, 20(4)
Journal of applied clinical medical physics / American College of Medical Physics, 20(4), 66-74. American Institute of Physics
Journal of Applied Clinical Medical Physics, 20(4), 66-74
Journal of Applied Clinical Medical Physics, 20(4)
Journal of applied clinical medical physics / American College of Medical Physics, 20(4), 66-74. American Institute of Physics
Journal of Applied Clinical Medical Physics, 20(4), 66-74
Purpose: To investigate the variation in computed dose-volume (DV) indices for high-dose-rate (HDR) prostate brachytherapy that can result from typical differences in computation settings in treatment planning systems (TPSs). Methods: Five factors we