Zobrazeno 1 - 10
of 32
pro vyhledávání: '"Marina Dojčinović"'
Publikováno v:
Medžiagotyra, Vol 30, Iss 4, Pp 568-575 (2024)
In this work, the morphology of the cavitation damage to centrifugally cast austenitic stainless alloys of the HP type was investigated. All specimens subjected to cavitation underwent detailed morphological analyses using light microscopy (LM) and s
Externí odkaz:
https://doaj.org/article/cb8057b94ea14252ab66aab113e82e57
Autor:
Radu, Marina Dojčinović, Radica Prokić Cvetković, Aleksandar Sedmak, Olivera Popović, Ivana Cvetković, Dorin
Publikováno v:
Materials; Volume 16; Issue 13; Pages: 4781
The effect of the shielding gas arc welding process on the cavitation resistance of the three-component aluminum alloy AlMg4.5Mn and its welded joints was investigated. Welding was performed using the GTAW and GMAW processes in a shielded atmosphere
Autor:
Ljubica Radović, Jovica Nešić, Marina Dojčinović, Melina Kalagasidis Krušić, Saša Brzić, Tihomir Kovačević, Jelena Rusmirović
Publikováno v:
Journal of Composite Materials
Two types of polymer waste materials, poly(ethylene terephthalate) (PET) and polycarbonate based Colombian Resin (CR-39), were used for the designing of fully recycled composite materials. Waste PET was employed for the synthesis of thermoset unsatur
Autor:
Marina Dojčinović, Slađana Jezdimirović, Marko Pavlović, Branka Purić, Aleksandar S. Cvetković
Publikováno v:
Advanced Technologies & Materials. 46:31-34
Cavitation resistance of polymer matrix / basalt powder composites was determined in this work. Two types of composites were tested: epoxy resin / basalt powder composite and polyester resin / basalt powder composite. In both cases, a basalt powder w
Publikováno v:
Zaštita materijala (2021) 62(2):95-105
Broken test tubes for low-cycle fatigue testing of Nionicral 70 (NN-70) parent material (PM) steel and simulated heat-affected zones (SHAZ) were used to produce samples for cavitation resistance testing. Ultrasonic vibrational cavitation method (stat
Publikováno v:
Science of Sintering, Vol 51, Iss 4, Pp 409-419 (2019)
Science of Sintering
Science of Sintering
The paper analyzes the morphology of cavitation damage of raw and sintered basalt samples. The experiment was conducted using the ultrasonic vibratory cavitation test method according to the ASTM G-32 standard. During the determination of the resista
Autor:
M Ljiljana Trumbulović, B Marina Dojčinović, D Ljubiša Andrić, D Marko Pavlović, S Dragan Radulovic
Publikováno v:
Tehnika (2021) 76(3):302-307
Tehnika, Vol 76, Iss 3, Pp 302-307 (2021)
Tehnika, Vol 76, Iss 3, Pp 302-307 (2021)
The paper present the results of the synthesis of a new refractory coating based on basalt for the protection of metal construction under conditions of cavitation. Initial basalt samples obtained from the locality Vrelo - Kopaonik. The basalt based r
Publikováno v:
Zaštita materijala (2021) 62(2):126-134
The resistance under the action of cavitation of sintered pyrophillite samples was investigated. The initial sample of pyrophillite from the Parsovic-BiH deposit was ground a vibrating mill to a granulation of 20 mm, pressed and sintered at temperatu
Autor:
Vesna Radojević, Milos Petrovic, Tatjana Volkov Husović, Marija M. Vuksanović, Radmila Jančić Heinemann, Almabrok A. Ashor, Nataša Z. Tomić, Marina Dojčinović
Publikováno v:
Polymer Bulletin
Composites based on poly(methyl methacrylate), dimethyl itaconate matrix and alumina particles were prepared. Ferrous oxide-doped alumina particles (Al2O3Fe) and commercial alumina nanoparticles (Al(2)O(3)n) modified with (3-aminopropyl)trimethoxysil
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ca43044c7dbc2c8a1c49c4b0213a599a
http://TechnoRep.tmf.bg.ac.rs/handle/123456789/4544
http://TechnoRep.tmf.bg.ac.rs/handle/123456789/4544
Publikováno v:
Materials Letters
In this study the resistance of cordierite and zircon to the cavitation erosion was investigated with the aim of possible spreading their application. Cavitation erosion test was applied using standard ultrasonic vibratory set up with stationary samp