Dumitru Toader, Maria Vintan
Publikováno v:
Mathematics, Vol 11, Iss 13, p 3032 (2023)
The electrical energy supply of industrial equipment is provided by electrical power stations with high- (HT), medium- (MV) and low-voltage (LV) busbars. Consumers are connected to either MV or LV busbars. In this paper, a real power station was cons
Externí odkaz:
https://doaj.org/article/d7c3291061cf4453b492daae96ef434f
Publikováno v:
Energies, Vol 14, Iss 21, p 7019 (2021)
The paper analyses how the characteristics of the medium-voltage network with insulated neutral and the conditions under which the single line-to-ground fault occurs (insulation condition and value of the fault resistance) influence the zero-sequence
Externí odkaz:
https://doaj.org/article/575f1cea867c45ffaa66323798e8e5a2
Autor:
Dumitru Toader, Marian Greconici, Daniela Vesa, Maria Vintan, Claudiu Solea, Adrian Maghet, Ildiko Tatai
Publikováno v:
Designs, Vol 5, Iss 3, p 53 (2021)
One important problem in the operation of medium voltage networks is the detection of a single-line-to-ground fault in its incipient state, when the fault resistance values are very high. In a medium voltage (MV) distribution network with a neutral g
Externí odkaz:
https://doaj.org/article/8dd78dd26ca74a9a8d1474397674d0c5
Publikováno v:
Energies, Vol 14, Iss 5, p 1330 (2021)
Settings of protection are essential to ensure the sensitivity and selectivity needed to detect defects. Making the correct settings requires the calculation of the fault currents with as little error as possible. Fault currents are influenced by the
Externí odkaz:
https://doaj.org/article/a83883edb7354b6abcbb2a4ad68b6dc1
Publikováno v:
2022 International Conference and Exposition on Electrical And Power Engineering (EPE).
Publikováno v:
Energies, Vol 14, Iss 7019, p 7019 (2021)
Energies
Volume 14
Issue 21
Energies
Volume 14
Issue 21
The paper analyses how the characteristics of the medium-voltage network with insulated neutral and the conditions under which the single line-to-ground fault occurs (insulation condition and value of the fault resistance) influence the zero-sequence
Publikováno v:
Energies, Vol 14, Iss 1330, p 1330 (2021)
Settings of protection are essential to ensure the sensitivity and selectivity needed to detect defects. Making the correct settings requires the calculation of the fault currents with as little error as possible. Fault currents are influenced by the
Autor:
Ildiko Tatai, Dumitru Toader, Marian Greconici, Daniela Vesa, Claudiu Solea, Maria Vintan, Adrian Maghet
Publikováno v:
Designs
Volume 5
Issue 3
Designs, Vol 5, Iss 53, p 53 (2021)
Volume 5
Issue 3
Designs, Vol 5, Iss 53, p 53 (2021)
One important problem in the operation of medium voltage networks is the detection of a single-line-to-ground fault in its incipient state, when the fault resistance values are very high. In a medium voltage (MV) distribution network with a neutral g
Autor:
Maria Vintan
Publikováno v:
Advances in Electrical and Computer Engineering, Vol 16, Iss 1, Pp 107-114 (2016)
The ground fault current distribution in an effectively grounded power network is affected by various factors, such as: tower footing impedances, spans lengths, configuration and parameters of overhead ground wires and power conductors, soil resistiv
Autor:
Maria Vintan
Publikováno v:
Advances in Electrical and Computer Engineering, Vol 10, Iss 2, Pp 43-47 (2010)
A phase-to-ground fault occurring on a transmission line divides the line into two sections, each extending from the fault towards one end of the line. These two sections of the line may be considered infinite if some certain conditions are met; othe