Renate Semrau, Frauke Verrel, Arne Koscielny, Jürgen Gieseke, Horst Urbach, Marcus von Falkenhausen, Hans H. Schild, Guido M. Kukuk, Winfried A. Willinek, Dariusch R. Hadizadeh, Kai Wilhelm, Ingrid Böhm
Publikováno v:
Magnetic Resonance Imaging. 28:1311-1318
Purpose To present the feasibility of highly undersampled contrast-enhanced MRA (CE-MRA) of the supraaortic arteries with a 16-channel neurovascular coil at 3.0 T using parallel imaging in two directions with parallel imaging factors (PIF) up to 16.
Autor:
Marcus von Falkenhausen, Gerhard Haidl, Sebastian Flacke, Holger Strunk, Michael Schuster, Hans H. Schild, A Kovacs
Publikováno v:
Radiology. 248:540-549
To identify predictors of future pregnancy in partners of infertile men undergoing embolization of varicoceles.This study was conducted within local institutional review board guidelines, and written informed consent was obtained. In 223 clinically i
Autor:
Marcus von Falkenhausen, Bernhard Meyer, Horst Urbach, Jürgen Gieseke, Hans H. Schild, Romhild M. Hoogeveen, Dariusch R. Hadizadeh, Winfried A. Willinek
Publikováno v:
Radiology. 246:205-213
To prospectively test the hypothesis that subsecond-temporal-resolution four-dimensional (4D) contrast material-enhanced magnetic resonance (MR) angiography at 3.0 T enables the same Spetzler-Martin classification (nidus size, venous drainage, eloque
Autor:
Oliver Walter, Carsten H. Meyer, N. Morakkabati, Winfried A. Willinek, Götz Lutterbey, R Blömer, Jürgen Gieseke, Christiane K. Kuhl, Hans H. Schild, Marcus von Falkenhausen
Publikováno v:
European Radiology. 17:1256-1261
The purpose of the study was to examine if the higher susceptibility at 3.0 Tesla (T) compared to 1.5 T will affect the contrast in MR imaging of the liver after application of superparamagnetic iron oxide particles (SPIO). The study was approved by
Autor:
Götz Lutterbey, Jürgen Gieseke, Hans H. Schild, Marcus von Falkenhausen, Christiane K. Kuhl, N. Morakkabati-Spitz, Frank Träber
Publikováno v:
Radiology. 241:538-545
This study had institutional review board approval; all 33 patients (mean age, 47 years +/- 16 [standard deviation]) gave informed consent. The aim was to prospectively evaluate the diagnostic image quality yielded by a 3.0-T T2-weighted turbo spin-e
Autor:
Christiane K. Kuhl, Jürgen Gieseke, Hans H. Schild, Winfried A. Willinek, Marcus von Falkenhausen, N. Morakkabati-Spitz, Oliver Walter, R Blömer, Götz Lutterbey
Publikováno v:
Radiology. 241:156-166
To prospectively evaluate whether magnetic resonance (MR) imaging of the liver at 3.0 T is comparable to that at 1.5 T with respect to image artifacts, image quality, and diagnostic utility in terms of detection and characterization of focal liver le
Is the body-coil at 3 Tesla feasible for the MRI evaluation of the painful knee? A comparative study
Autor:
N. Morakkabati, Jürgen Gieseke, Mike P. Wattjes, H. H. Schild, Götz Lutterbey, K Behrends, Marcus von Falkenhausen
Publikováno v:
European Radiology. 17:503-508
The purpose of this study was to compare the in-built body coil of the 3.0-Tesla (T) scanner with a dedicated surface coil of a 1.5 T system regarding knee imaging. We performed an intraindividual prospective clinical trial on 17 patients with knee p
Autor:
Claudia Leutner, Christiane K. Kuhl, Marcus von Falkenhausen, Götz Lutterbey, Hans H. Schild, N. Morakkabati-Spitz
Publikováno v:
Radiology. 238:438-445
To prospectively evaluate whether the descriptors of lesion features and the diagnostic criteria that have been established for breast magnetic resonance (MR) imaging in female patients may be used for differential diagnosis with breast MR imaging in
Autor:
Hans H. Schild, Oliver Zivanovic, Frank Träber, Götz Lutterbey, Christiane K. Kuhl, N. Morakkabati-Spitz, Tjoung-Won Park-Simon, Marcus von Falkenhausen, Jiirgen Gieseke
Publikováno v:
European Radiology. 16:634-641
The higher signal at 3.0-T allows spatial resolution to be increased without loss in image quality. We evaluated a T2-weighted turbo spin-echo sequence with high spatial resolution (3T-HR) to determine whether this provides clinically useful pelvic M
Autor:
Michael Stoffel, Marcus von Falkenhausen, Goetz Lutterbey, A. Schmitz, Lars Victor von Engelhardt
Publikováno v:
Journal of Manipulative and Physiological Therapeutics. 28:633-636
Objective To present the rare case of a displaced odontoid fracture after manipulative treatment. Clinical Features A 37-year-old, 15-week pregnant patient was referred with acute neck pain and a diffuse paravertebral swelling that started after cerv