Marcos A. Donolo, Carlos Martin Pezzani, Pablo Donolo, Guillermo R. Bossio, Cristian H. De Angelo
Publikováno v:
IAS
Heating and losses of induction motor (IM) grow with the supply voltage unbalance and harmonic distortion. To avoid thermal overload, the IEEE 141-1993, the IEEE 3004.8, NEMA MG1-2014, and the IEC 60034-26 standards establish derating factors for IMs
Publikováno v:
The Journal of Engineering. 2018:866-870
Autor:
Pablo Donolo, Marcos A. Donolo, Cristian H. De Angelo, Guillermo O. Garcia, Guillermo R. Bossio
Publikováno v:
Electric Power Systems Research. 140:866-873
Voltage unbalance and harmonic voltage distortion affect the power, torque and vibrations on induction motors (IM). In this paper, we compute the frequency of the oscillations of the power, torque and vibrations due to voltage unbalance and harmonics
Publikováno v:
IEEE Transactions on Power Delivery. 21:1803-1808
Frequency recording units (FRUs), designed to measure power systems' frequency at low voltage, are affected by the connection of large loads causing sudden phase shifts and magnitude changes in the voltage. These phase shifts introduce spikes in the
Publikováno v:
Computers & Electrical Engineering. 29:643-651
The calculation of power transmission lines parameters of electric energy has a fundamental importance in the design, construction and simulation of electric power systems. Generally, the results obtained are used in the database for the studies of p
Autor:
Armando Guzman, David E. Whitehead, Edmund O. Schweitzer, Yanfeng Gong, Roy Moxley, Marcos A. Donolo
Publikováno v:
IEEE PES T&D 2010.
Synchrophasors have been applied in numerous applications to improve power system operations. Today, they are providing solutions that otherwise would have been too expensive or too complicated to implement with traditional approaches. As application
Publikováno v:
2010 63rd Annual Conference for Protective Relay Engineers.
Distributed generation (DG) is gaining popularity in the United States and across the world. The Florida Public Service Commission recently passed rules encouraging the use of renewable resources. Integrating DG with the utility network poses challen
Publikováno v:
2009 IEEE/PES Power Systems Conference and Exposition.
The two main load centers in the Natal region of the Eskom power system in South Africa are susceptible to voltage collapse during stressed operating conditions. Combined, these two load centers carry about 6,700 MW during peak conditions. Potential
Autor:
Marcos A. Donolo, Virgilio A. Centeno
Publikováno v:
IEEE Transactions on Power Delivery. 23:504-505
The IEEE synchrophasor standard for power systems C37.118 provides a basis for interoperability of compliant phasor measurement units. A section of this standard deals with tests to enforce measurements error limits. In this letter, we review the ver