Bioactive Materials, Vol 6, Iss 1, Pp 12-25 (2021)
Treatment of implant-associated infection is becoming more challenging, especially when bacterial biofilms form on the surface of the implants. Developing multi-mechanism antibacterial methods to combat bacterial biofilm infections by the synergistic
Externí odkaz:
https://doaj.org/article/f6dba97f73214a18861f1f0f3ea66c9f
Publikováno v:
Carbon Letters. 33:373-385
Publikováno v:
Rare Metals. 41:540-545
Bio-inertness and post-surgery infection on titanium (Ti) are the main causes of failure of biomedical implants in vivo. Near-infrared (NIR) photoactivated antibacterial therapy including photothermal and photodynamic therapies has attracted increasi
Autor:
Shuxin, Lu, Ruoyu, Li, Maozhou, Chai, Jiameng, Wang, Wangping, Duan, Xiaohong, Yao, Xiangyu, Zhang, Bin, Tang
Publikováno v:
Colloids and surfaces. B, Biointerfaces. 217
Bacterial infection of titanium (Ti) dental implants is still a major clinical complication. In this study, a combination of copper (Cu) ions and photothermal therapy is used to combat implant-associated infection. Cu doped TiO
Publikováno v:
Bioactive Materials
Bioactive Materials, Vol 6, Iss 1, Pp 12-25 (2021)
Bioactive Materials, Vol 6, Iss 1, Pp 12-25 (2021)
Treatment of implant-associated infection is becoming more challenging, especially when bacterial biofilms form on the surface of the implants. Developing multi-mechanism antibacterial methods to combat bacterial biofilm infections by the synergistic
Publikováno v:
Materials scienceengineering. C, Materials for biological applications. 129
Infection and inflammation are the main causes resulting in the failure of dental implants. In this work, molybdenum diselenide (MoSe
Publikováno v:
Biomedical materials (Bristol, England). 16(2)
Implant-associated infections is a main factor leading to the failure of titanium (Ti) implants. Micro-arc oxidation is a convenient and effective technique to form a biocompatible metal (Ag
Publikováno v:
Materials Performance and Characterization. 11:20210121
Publikováno v:
Materials Science and Engineering: C. 129:112416
Infection and inflammation are the main causes resulting in the failure of dental implants. In this work, molybdenum diselenide (MoSe2) was synthesized hydrothermally on the surface of porous TiO2 coating prepared by micro-arc oxidation on titanium (
Publikováno v:
Biomedical Materials. 16:025018
Implant-associated infections is a main factor leading to the failure of titanium (Ti) implants. Micro-arc oxidation is a convenient and effective technique to form a biocompatible metal (Ag+, Cu2+ and Zn2+) ions-doped TiO2 coatings to combat bacteri