Zobrazeno 1 - 10
of 10
pro vyhledávání: '"Manda Švabić-Kolacio"'
Autor:
Nevena Obajdin, Đeni Smilović-Radojčić, Dag Zahirović, Manda Švabić-Kolacio, David Rajlić, Ingrid Belac-Lovasić, Slaven Jurković
Publikováno v:
Libri Oncologici, Vol 48, Iss 2-3, Pp 47-53 (2020)
Introduction: Within the past two decades, we made significant progress in radiation therapy for prostate cancer. At UH Rijeka IMRT became the technique of choice for radiation therapy following radical prostatectomy since 2016. Previously, an advanc
Externí odkaz:
https://doaj.org/article/2e8ef3dd80284d5c9afd3a9431e7fd2e
Autor:
David Rajlić, Bozidar Casar, Djeni Smilovic Radojcic, Nevena Obajdin, Slaven Jurković, Manda Švabić Kolacio, Dea Dundara Debeljuh, Ignasi Mendez
Publikováno v:
Radiology and Oncology, Vol 54, Iss 4, Pp 495-504 (2020)
Radiology and Oncology
Radiology and oncology
Volume 54
Issue 4
Radiology and Oncology
Radiology and oncology
Volume 54
Issue 4
Introduction Advanced, Monte Carlo (MC) based dose calculation algorithms, determine absorbed dose as dose to medium-in-medium (D m,m) or dose to water-in-medium (D w,m). Some earlier studies identified the differences in the absorbed doses related t
Autor:
Manda Švabić-Kolacio, David Rajlić, Đeni Smoilović-Radojčić, Slaven Jurković, Dag Zahirović, Ingrid Belac-Lovasić, Nevena Obajdin
Publikováno v:
Libri Oncologici, Vol 48, Iss 2-3, Pp 47-53 (2020)
Libri Oncologici : Croatian Journal of Oncology
Volume 48
Issue 2-3
Libri Oncologici : Croatian Journal of Oncology
Volume 48
Issue 2-3
Introduction: Within the past two decades, we made significant progress in radiation therapy for prostate cancer. At UH Rijeka IMRT became the technique of choice for radiation therapy following radical prostatectomy since 2016. Previously, an advanc
The most accurate absorbed dose calculation in radiation oncology nowadays is provided by Monte Carlo (MC) based algorithms. Such algorithms inherently calculate absorbed dose to medium in medium Dm, m. They can also provide data as absorbed dose to
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=57a035e5b1ae::97bc9b1424d9bf5d2ff647353d9dd625
https://www.bib.irb.hr/1249503
https://www.bib.irb.hr/1249503
Autor:
Ana Božanić, Doris Šegota, Dea Dundara Debeljuh, Manda Švabić Kolacio, Đeni Smilović Radojčić, Katarina Ružić, Mirjana Budanec, Mladen Kasabašić, Darijo Hrepić, Petra Valković Zujić, Marco Brambilla, Mannudeep K. Kalra, Slaven Jurković
Publikováno v:
Physica Medica
Volume 96
Volume 96
Objective: To present results of the first national survey on reference levels of CT imaging performed for the treatment planning purposes in radiation oncology in Croatia. Methods: Data for CT protocols of five anatomical regions including head, hea
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::3b56372e39375ba3bba8fe77b8bc8c18
https://doi.org/10.1016/j.ejmp.2022.03.001
https://doi.org/10.1016/j.ejmp.2022.03.001
Autor:
Manda Švabić Kolacio, David Rajlić, Milan Radojčić, Ðeni Smilović Radojčić, Nevena Obajdin, Dea Dundara Debeljuh, Slaven Jurković
Publikováno v:
Reports of Practical Oncology and Radiotherapy
Volume 27
Issue 1
Volume 27
Issue 1
Background: Study determines differences in calculated dose distributions for Non-Small Cell Lung Carcinoma (NSCLC) patients. NSCLC cases were investigated, NSCLC being the most common lung cancer treated by radiotherapy in our clinical practice. Mat
Autor:
Slaven Jurković, Đeni Smilović Radojčić, Dario Faj, Manda Švabić Kolacio, David Rajlić, Hrvoje Brkić, Nevena Obajdin
Introduction: The calculation algorithm for intensity modulated radiotherapy (IMRT) built in the Elekta Monaco treatment planning system (TPS) is based on Monte Carlo (MC) simulation. Absorbed dose is calculated as dose to medium in medium (Dm, m), b
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::2eef754668e384f3a18cae7e1f48ede5
https://www.bib.irb.hr/1086080
https://www.bib.irb.hr/1086080
Autor:
Dario Faj, Đeni Smilović Radojčić, Manda Švabić Kolacio, Slaven Jurković, David Rajlić, Bozidar Casar, Nevena Obajdin
Publikováno v:
Radiology and Oncology
Volume 52
Issue 3
Radiology and Oncology, Vol 52, Iss 3, Pp 346-352 (2018)
Volume 52
Issue 3
Radiology and Oncology, Vol 52, Iss 3, Pp 346-352 (2018)
Background The accuracy of dose calculation is crucial for success of the radiotherapy treatment. One of the methods that represent the current standard for patient-specific dosimetry is the evaluation of dose distributions measured with an ionizatio
Autor:
Slaven Jurković, Manda Švabić Kolacio, Milan Radojčić, B. Casar, Dario Faj, Ðeni Smilović Radojčić, David Rajlić
Publikováno v:
Medical dosimetry
Volume 43
Issue 4
Volume 43
Issue 4
Advanced dose calculation algorithms for radiation therapy treatment planning can report external beam photon dose 2-sided, in terms of dose-to-medium (Dm) and dose-to-water (Dw). The purpose of our study was to determinate the effect of Dw and Dm re
Introduction Implementation of advanced radiotherapy techniques makes high demands on the treatment planning system (TPS). Purpose Dosimetric evaluation of calculation algorithm built in Monte Carlo (MC) based TPS. Materials and methods Dose distribu
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::8f8c243f159df9051b43b8ae97d1d030
https://www.bib.irb.hr/844103
https://www.bib.irb.hr/844103