Zobrazeno 1 - 8
of 8
pro vyhledávání: '"Manabu Ishino"'
Publikováno v:
Journal of Infrared, Millimeter, and Terahertz Waves. 42:416-425
A novel type of near-field slit probe with high sensitivity and high spatial resolution is proposed. We tested the implementation of this in passive millimeter-wave microscopy at frequencies around 50 GHz. The slit probe comprises a standard rectangu
The study of protein functions attributed to the conformation and fluctuation that are ruled by both the amino acid sequence and thermodynamics, requires thermodynamic quantities given by calorimetry using thermometric techniques. The increased need
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::df70d65c184aa158b008765619848767
http://arxiv.org/abs/1904.00524
http://arxiv.org/abs/1904.00524
Publikováno v:
Journal of Applied Physics; 2015, Vol. 118 Issue 11, p114905-1-114905-8, 8p, 3 Diagrams, 6 Graphs
Publikováno v:
2016 41st International Conference on Infrared, Millimeter, and Terahertz waves (IRMMW-THz).
We report on an analytical method for investigating the signal contrast obtained in near-field scanning millimeter-wave microscopy using a metal slit probe. The probe has a slit-like aperture at the open end of a rectangular metal waveguide. In our m
Publikováno v:
2012 37th International Conference on Infrared, Millimeter, and Terahertz Waves.
Passive millimeter-wave microscopy that enables imaging of the thermal radiation emitted from a viewed sample with a spatial resolution below the diffraction limit is investigated. Experiments performed at 50 GHz (λ = 6 mm) at various sample tempera
Publikováno v:
2012 37th International Conference on Infrared, Millimeter, and Terahertz Waves.
A novel type of apertureless near-field microscopy using a knife blade as a scanning probe is proposed and investigated at millimeter wavelengths. Since the knife blade probe is a wider version of the metal tip probe commonly used in this technique,
Publikováno v:
Review of Scientific Instruments. 84(3):036103-036103-3
Imaging of thermal radiation with a spatial resolution below the diffraction limit is demonstrated with a passive millimeter-wave microscope. This technique utilizes a sensitive radiometric receiver in combination with a scanning near-field microscop
Apertureless near-field microscopy using a knife blade as a scanning probe at millimeter wavelengths
Publikováno v:
Journal of Applied Physics. 112(7):074907-074907-6
We report on the use of a knife blade as a scanning probe for apertureless near-field microscopy at millimeter wavelengths. Since the knife blade probe is a wider version of the metal tip probe commonly used in this technique, and therefore the inter