Zobrazeno 1 - 10
of 84
pro vyhledávání: '"Makoto Tada"'
Publikováno v:
Thoracic Cancer, Vol 14, Iss 22, Pp 2222-2224 (2023)
Abstract We present the case of a patient who developed pulmonary artery occlusion following immune‐checkpoint inhibitor (ICI) therapy for non‐small cell lung cancer. A 69‐year‐old man with squamous cell carcinoma (yc‐T1cN0M0), initially di
Externí odkaz:
https://doaj.org/article/8b863fd8a52146d59f6178fcec550086
Autor:
Yuki Takahashi, Ryunosuke Maki, Kodai Tsuruta, Makoto Tada, Wataru Arai, Yuma Shindo, Yasuyuki Nakamura, Masahiro Miyajima, Atsushi Watanabe
Publikováno v:
Journal of Cardiothoracic Surgery, Vol 17, Iss 1, Pp 1-6 (2022)
Abstract Background Soft coagulation using the VIO soft coagulation system is used to treat minor lung air leaks during pulmonary resection in Japan. We previously reported that it has a similar effect as the air leak treatment with fibrin glue. We e
Externí odkaz:
https://doaj.org/article/503927ac4f9d44d8b19c1ffc1aa23764
Autor:
Toshiyuki Sumi, Hirofumi Uehara, Toshiaki Masaoka, Makoto Tada, Yoshiko Keira, Koki Kamada, Naoki Shijubou, Yuichi Yamada, Hisashi Nakata, Yuji Mori, Hirofumi Chiba
Publikováno v:
Thoracic Cancer, Vol 11, Iss 11, Pp 3396-3400 (2020)
A clinical trial of immune checkpoint inhibitors for advanced non‐small cell lung cancer reported an overall survival plateau with a long tail to the survival curve, suggesting that immune checkpoint inhibitors prolong survival. However, little evi
Externí odkaz:
https://doaj.org/article/35de8e9798db4234be915445b5724461
Unexpected haemorrhage from lateral thoracic artery following the removal of a pleural drainage tube
Publikováno v:
Respirology Case Reports, Vol 9, Iss 12, Pp n/a-n/a (2021)
Abstract Pulmonologists must be aware of the possible arterial bleeding even during the removal of a safely inserted drain.
Externí odkaz:
https://doaj.org/article/919a94e3554043349ba65255cf565d16
Autor:
Yuki Takahashi, Masahiro Miyajima, Makoto Tada, Ryunosuke Maki, Taijiro Mishina, Atsushi Watanabe
Publikováno v:
Journal of Cardiothoracic Surgery, Vol 14, Iss 1, Pp 1-6 (2019)
Abstract Background Completion lobectomy long after segmentectomy in the same lobe is extremely difficult because of severe adhesions around hilar structures, especially in cases involving video-assisted thoracoscopic surgery (VATS) completion lobect
Externí odkaz:
https://doaj.org/article/f47ce9e065314201be5bd53b64c5f1e7
Autor:
Toshiyuki Sumi, Hirofumi Uehara, Makoto Tada, Yoshiko Keira, Koki Kamada, Naoki Shijubou, Yuichi Yamada, Hisashi Nakata, Yuji Mori, Hirofumi Chiba
Publikováno v:
Respirology Case Reports, Vol 9, Iss 3, Pp n/a-n/a (2021)
Abstract Interstitial lung disease (ILD) is a common complication of systemic sclerosis (SSc). Nintedanib, an antifibrotic drug, has recently been approved for treating SSc‐ILD. Although there have been no reports suggesting the development of pneu
Externí odkaz:
https://doaj.org/article/0897b0f4f2724df3a0ed4c001caa18d6
Autor:
Yuki Takahashi, Masahiro Miyajima, Taijiro Mishina, Ryunosuke Maki, Makoto Tada, Kodai Tsuruta, Atsushi Watanabe
Publikováno v:
Journal of Cardiothoracic Surgery, Vol 13, Iss 1, Pp 1-4 (2018)
Abstract Background Combined resection of a phrenic nerve is occasionally required in T3 primary lung carcinomas invading the phrenic nerve to completely remove a malignant tumour, resulting in diaphragmatic paralysis. We describe the first case of t
Externí odkaz:
https://doaj.org/article/57dd7acfe46c451aa05d2fa47f3d9c23
Autor:
Hideaki KATO, Kazuki OGAWA, Makoto TADA, Yoshiho ODA, Xiaojun LIU, Ayato ENDO, Keigo IKEDA, Takayoshi NARITA
Publikováno v:
Mechanical Engineering Journal, Vol 5, Iss 5, Pp 18-00080-18-00080 (2018)
Levitation improvement of the bending levitation performance of thin steel plate was performed. First, the point of the steel plate where the vibration is predominantly generated was estimated using an ultrathin steel plate with a thickness of 0.18 m
Externí odkaz:
https://doaj.org/article/7f38a889d05a4a7ca38305b34224a749
Publikováno v:
Actuators, Vol 7, Iss 3, p 43 (2018)
When an ultrathin and flexible steel plate is to be levitated, levitation control becomes difficult because the ultrathin steel plate undergoes increased flexure. We herein propose a levitation method for an ultrathin steel plate that is bent to an e
Externí odkaz:
https://doaj.org/article/fe7c94aacf9f4e42bc56c6c359b32f63
Autor:
Yuma Shindo, Masahiro Miyajima, Yasuyuki Nakamura, Yoshiki Chiba, Wataru Arai, Miho Aoyagi, Ryunosuke Maki, Kodai Tsuruta, Yuki Takahashi, Makoto Tada, Yoshiaki Takase, Atsushi Watanabe
Publikováno v:
Surgery Today. 53:428-434
The accuracy of lymph node (LN) dissection in robotic surgery for lung cancer remains controversial. We compared the accuracy of LN dissection in robot-assisted thoracic surgery (RATS) vs. video-assisted thoracic surgery (VATS).The subjects of this r