Samples of unadditised, middle distillate diesel fuel were injected through real-size optically accessible mini-sac diesel injectors into ambient air at common rail pressures of 250 and 350 bar, respectively. High-resolution images of white light sca
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::9d540e1a3bc7701c18ff0ff0d0b9bed7
High-speed planar laser Mie scattering and Laser Induced Fluorescence (PLIF) was employed for the determination of Sauter Mean Diameter (SMD) distribution in non-evaporating diesel sprays. The effect of rail pressure, distillation profile, and conseq
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::94ec9e2228b3097be501c9354138d2c8
Autor:
R. D. Lockett, Mahesh Jeshani
Samples of commercial diesel were subjected to 40 h of intense cavitation flow across a diesel injector in a specially designed high-pressure recirculation flow rig. Changes to the optical absorption and scattering properties of the diesel over time
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::04713453d9b460b380be850ca51785bc
https://openaccess.city.ac.uk/id/eprint/8187/1/IJER_Hydrodynamic_Cavitation_Paper.pdf
https://openaccess.city.ac.uk/id/eprint/8187/1/IJER_Hydrodynamic_Cavitation_Paper.pdf
Two identical, conventional six-hole, valve-covered orifice (VCO) diesel injectors have been modified in order to provide optical access to the region below the needle, and the nozzle-flow passages. This has been achieved through the removal of the m