Zobrazeno 1 - 8
of 8
pro vyhledávání: '"Magnus, Aslund"'
Publikováno v:
Biomedical Optics 2014.
We validated a new method combining stand-alone 2D mammogram with functional DOT imaging. 2D-guided optical reconstruction reveals similar statistics to spatially co-registered 3D-guided reconstruction in differentiating tumor from other tissues.
Purpose: To provide a cascaded-systems framework based on the noise-power spectrum (NPS), modulation transfer function (MTF), and noise-equivalent number of quanta (NEQ) for quantitative evaluation of differential phase-contrast imaging (Talbot inter
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::de83cc8b45126094751d611cdd06ec51
http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-104708
http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-104708
Publikováno v:
Medical physics. 37(5)
Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. The authors have investigated a photon-counting spectral imaging system with t
Publikováno v:
Medical physics. 36(2)
A multiprism lens (MPL) is a refractive x-ray lens with one-dimensional focusing properties. If used as a pre-object collimator in a scanning system for medical x-ray imaging, it reduces the divergence of the radiation and improves on photon economy
Autor:
David R. Dance, Kenneth C. Young, Magnus Aslund, Patrice Heid, Ramona W. Bouwman, Roeland Burght, Ruben E. van Engen, Barbara Lazzari
Publikováno v:
Digital Mammography ISBN: 9783540705376
Digital Mammography / IWDM
Digital Mammography / IWDM
Breast tomosynthesis systems are developed by a number of manufacturers. It is desirable to have methods for image quality evaluation that can be used for quality control and minimum performance. In this study methods of measurement of three aspects
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::d88078d114a231d37675c0ffd84f8974
https://doi.org/10.1007/978-3-540-70538-3_96
https://doi.org/10.1007/978-3-540-70538-3_96
Publikováno v:
Medical physics. 34(6)
The physical performance of a scanning multislit full field digital mammography system was determined using basic image quality parameters. The system employs a direct detection detector comprised of linear silicon strip sensors in an edge-on geometr
Publikováno v:
Medical physics. 33(4)
The scatter to primary ratio (SPR) was measured on a scanning multislit full-field digital mammography system for different thickness of breast equivalent material and different tube voltages. Scatter within the detector was measured separately and w
Publikováno v:
Medical physics. 32(11)
A theoretical evaluation of nonuniform x-ray field distributions in mammography was conducted. An automatic exposure control (AEC) is proposed for a scanning full field digital mammography system. It uses information from the leading part of the dete