Zobrazeno 1 - 10
of 23
pro vyhledávání: '"MESH: Prosthesis Design"'
Autor:
Suzanne Kats, Andrea Blasio, Evaldas Girdauskas, Marco Solinas, Malakh Shrestha, Basel Ramlawi, Nikolaos Bonaros, Claudio Muneretto, Theodor Fischlein, Sidney Chocron, Manfredo Rambaldini, Anna McGlothlin, Douglas R. Johnston, Giovanni Troise, Denis Bouchard, Roberto Lorusso, Elisabet Berastegui, Daniel Bitran, Mahesh Ramchandani, Julio García-Puente, Utz Kappert, Jose Cuenca Castillo, Salvatore Tribastone, Sami Kueri, Martin Andreas, Gabriel Maluenda, Frédéric Pinaud, David Heimansohn, Dina De Bock, Filip Rega, Thorsten Hanke, Alberto Repossini, Steffen Pfeiffer, Elisa Mikus, Olivier Fabre, Bart Meuris, Laurent de Kerchove, Kevin Teoh, Eric E. Roselli, Erwin S.H. Tan, Shaohua Wang, André Vincentelli, Anno Diegeler, Pierre Voisine, Martin Grabenwoeger, Mattia Glauber, Peter Oberwalder, Thierry Folliguet, Matthias Siepe, Ehud Raanani, Pierre Corbi, Bernard Albat
Publikováno v:
Journal of Thoracic and Cardiovascular Surgery, 161(3), 920-932. MOSBY-ELSEVIER
Journal of Thoracic and Cardiovascular Surgery
Journal of Thoracic and Cardiovascular Surgery, Elsevier, 2021, 161 (3), pp.920-932. ⟨10.1016/j.jtcvs.2020.11.162⟩
Journal of Thoracic and Cardiovascular Surgery
Journal of Thoracic and Cardiovascular Surgery, Elsevier, 2021, 161 (3), pp.920-932. ⟨10.1016/j.jtcvs.2020.11.162⟩
International audience; Objective: Sutureless aortic valves are a novel option for aortic valve replacement. We sought to demonstrate noninferiority of sutureless versus standard bioprostheses in severe symptomatic aortic stenosis.Methods: The Percev
Characterization of the Effective Orifice Areas of Mitral Prosthetic Heart Valves: An In Vitro Study
Publikováno v:
Journal of Heart Valve Disease
Journal of Heart Valve Disease, Icr Publishers, 2017, 26 (6), pp.677-687
Journal of Heart Valve Disease, Icr Publishers, 1970, 26 (6), pp.677-687
Journal of Heart Valve Disease, 2017, 26 (6), pp.677-687
Scopus-Elsevier
Europe PubMed Central
Journal of Heart Valve Disease, 1970, 26 (6), pp.677-687
Journal of Heart Valve Disease, Icr Publishers, 2017, 26 (6), pp.677-687
Journal of Heart Valve Disease, Icr Publishers, 1970, 26 (6), pp.677-687
Journal of Heart Valve Disease, 2017, 26 (6), pp.677-687
Scopus-Elsevier
Europe PubMed Central
Journal of Heart Valve Disease, 1970, 26 (6), pp.677-687
BACKGROUND: Reference values of hemodynamic parameters for the assessment of prosthetic heart valves are necessary, and ideally need to be provided by entities independent of the valve manufacturers. Thus, the study aim was to provide, in vitro, norm
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=pmid_dedup__::6db0d586639a4077e9b24bbf95f3dc88
https://hal.archives-ouvertes.fr/hal-01843145/file/tex00000483.pdf
https://hal.archives-ouvertes.fr/hal-01843145/file/tex00000483.pdf
Publikováno v:
Indian Journal of Orthopaedics, Vol 48, Iss 4, Pp 410-414 (2014)
Indian Journal of Orthopaedics
Indian Journal of Orthopaedics
Background: One of the reasons that hip resurfacing and large head metal on metal (MOM) total hip arthroplasty (THA) became popular in Asia was the possible increased range of movement and thereby improved function of the hip joint. Due to concerns o
Publikováno v:
Journal of the Acoustical Society of America
Journal of the Acoustical Society of America, Acoustical Society of America, 2013, 134 (1), pp.503-9. ⟨10.1121/1.4807900⟩
Journal of the Acoustical Society of America, 2013, 134 (1), pp.503-9. ⟨10.1121/1.4807900⟩
Journal of the Acoustical Society of America, Acoustical Society of America, 2013, 134 (1), pp.503-9. ⟨10.1121/1.4807900⟩
Journal of the Acoustical Society of America, 2013, 134 (1), pp.503-9. ⟨10.1121/1.4807900⟩
International audience; Users of Advanced Bionics, MedEl, and Cochlear Corp. implants balanced the loudness of trains of asymmetric pulses of opposite polarities presented in monopolar mode. For the Advanced Bionics and MedEl users the pulses were tr
Autor:
Issam Abouliatim, Adrien Kaladji, Boris Campillo-Gimenez, Alain Cardon, Jean François Heautot, Jean-Philippe Verhoye
Publikováno v:
Journal of Vascular Surgery
Journal of Vascular Surgery, 2012, 55 (5), pp.1287-95. ⟨10.1016/j.jvs.2011.11.122⟩
Journal of Vascular Surgery, Elsevier, 2012, 55 (5), pp.1287-95. ⟨10.1016/j.jvs.2011.11.122⟩
Journal of Vascular Surgery, 2012, 55 (5), pp.1287-95. ⟨10.1016/j.jvs.2011.11.122⟩
Journal of Vascular Surgery, Elsevier, 2012, 55 (5), pp.1287-95. ⟨10.1016/j.jvs.2011.11.122⟩
International audience; BACKGROUND: Aneurysmal regression is a reliable marker for long-lasting success after endovascular aneurysm repair (EVAR). The aim of this study was to identify the preoperative factors that can predictably lead to aneurysmal
Autor:
Jaume Bosch, Juan-G Abraldes, Christophe Bureau, Pablo Bellot, Pierre Perreault, Sophie Metivier, Hervé Rousseau, Philippe Otal, Jean-Pierre Vinel, Gilles Pomier Layrargues, Juan Carlos Garcia Pagan, Jean-Marie Péron
Publikováno v:
Liver International
Liver International, 2007, 27 (6), pp.742-7. ⟨10.1111/j.1478-3231.2007.01522.x⟩
Liver International, 2007, 27 (6), pp.742-7. ⟨10.1111/j.1478-3231.2007.01522.x⟩
International audience; An 80% dysfunction rate at 2 years limits the use of transjugular intrahepatic portosystemic shunts (TIPS) in the treatment of complications of portal hypertension. The use of covered stents could improve shunt patency; howeve
Autor:
Jacques Magnan, Renaud Meller, Frédéric Venail, Jean Pierre Lavieille, Laurent Tardivet, Arnaud Deveze
Publikováno v:
Laryngoscope
Laryngoscope, Wiley, 2007, 117 (3), pp.552-5. ⟨10.1097/MLG.0b013e31802dfc59⟩
Laryngoscope, Wiley, 2007, 117 (3), pp.552-5. ⟨10.1097/MLG.0b013e31802dfc59⟩
International audience; Middle ear implantation is an efficient procedure to restore moderate to severe sensorineural hearing loss (HL) in selected patients. Implantation of such devices requires ossicular chain integrity. Patients suffering from oto
Autor:
Pascal Defaye, Dominique Babuty, Jean-Pierre Cebron, Philippe Mabo, Frédéric Anselme, Jean-Claude Daubert, Olivier Paziaud, Elisabeth Mouton, Jean Marc Davy, Pierre Mondoly, Aude Tassin
Publikováno v:
Journal of Cardiovascular Electrophysiology
Journal of Cardiovascular Electrophysiology, Wiley, 2012, 23 (8), pp.853-60. ⟨10.1111/j.1540-8167.2012.02311.x⟩
Journal of Cardiovascular Electrophysiology, Wiley, 2012, 23 (8), pp.853-60. 〈10.1111/j.1540-8167.2012.02311.x〉
Journal of Cardiovascular Electrophysiology, 2012, 23 (8), pp.853-60. ⟨10.1111/j.1540-8167.2012.02311.x⟩
Journal of Cardiovascular Electrophysiology, Wiley, 2012, 23 (8), pp.853-60. ⟨10.1111/j.1540-8167.2012.02311.x⟩
Journal of Cardiovascular Electrophysiology, Wiley, 2012, 23 (8), pp.853-60. 〈10.1111/j.1540-8167.2012.02311.x〉
Journal of Cardiovascular Electrophysiology, 2012, 23 (8), pp.853-60. ⟨10.1111/j.1540-8167.2012.02311.x⟩
Impact of Recalls on ICD Utilization. Introduction: The study was designed to evaluate the feasibility and performance of right ventricular (RV) mid-septal versus apical implantable defibrillator (ICD) lead placement. Methods and Results: SEPTAL is a
Autor:
Griffet, J.
Publikováno v:
Orthopaedics and Traumatology-Surgery and Research
Orthopaedics and Traumatology-Surgery and Research, Elsevier, 2016, 102 (1), pp.S161-S175. ⟨10.1016/j.otsr.2015.03.020⟩
Orthopaedics and Traumatology-Surgery and Research, Elsevier, 2016, 102 (1), pp.S161-S175. ⟨10.1016/j.otsr.2015.03.020⟩
Opinion/Feedback Amputation of a limb is always perceived as a catastrophe. The principles underlying creation of a stump adapted to modern prosthetic fittings must be fully understood and the patient managed by a multidisciplinary team. In paediatri
Autor:
Adrien Hertault, Stéphan Haulon, R. Spear, Jonathan Sobocinski, Adrien Kaladji, Blandine Maurel
Publikováno v:
European Journal of Vascular and Endovascular Surgery
European Journal of Vascular and Endovascular Surgery, 2013, 46 (1), pp.82-6. ⟨10.1016/j.ejvs.2013.04.012⟩
European Journal of Vascular and Endovascular Surgery, Elsevier, 2013, 46 (1), pp.82-6. ⟨10.1016/j.ejvs.2013.04.012⟩
European Journal of Vascular and Endovascular Surgery, 2013, 46 (1), pp.82-6. ⟨10.1016/j.ejvs.2013.04.012⟩
European Journal of Vascular and Endovascular Surgery, Elsevier, 2013, 46 (1), pp.82-6. ⟨10.1016/j.ejvs.2013.04.012⟩
International audience; BACKGROUND: To assess the accuracy of the aortic outer curvature length for thoracic endograft planning. METHODS: Seventy-four patients (58 men, 66.4 ± 14 years) who underwent thoracic endovascular aortic repair between 2009
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::39afba4ceeb677b036bb79c58b2fdd28
https://www.hal.inserm.fr/inserm-00881625
https://www.hal.inserm.fr/inserm-00881625