Zobrazeno 1 - 10
of 187
pro vyhledávání: '"MATTINGLY, J. A."'
Autor:
Adamski, S., Ahn, M., Barbeau, P. S., Belov, V., Bernardi, I., Bock, C., Bolozdynya, A., Bouabid, R., Browning, J., Cabrera-Palmer, B., Cedarblade-Jones, N., Rivera, J. Colón, Conley, E., da Silva, V., Daughhetee, J., Detwiler, J., Ding, K., Durand, M. R., Efremenko, Y., Elliott, S. R., Erlandson, A., Fabris, L., Galindo-Uribarri, A., Green, M. P., Hakenmüller, J., Heath, M. R., Hedges, S., Jeong, H., Johnson, B. A., Johnson, T., Jones, H., Khromov, A., Konovalov, A., Kozlova, E., Kumpan, A., Kyzylova, O., Lee, Y., Li, G., Li, L., Link, J. M., Liu, J., Luxnat, M., Major, A., Mann, K., Markoff, D. M., Mattingly, J., Moye, J., Mueller, P. E., Newby, J., Ogoi, N., O'Reilly, J., Parno, D. S., Pérez-Loureiro, D., Pershey, D., Prior, C. G., Queen, J., Rapp, R., Ray, H., Razuvaeva, O., Reyna, D., Rich, G. C., Rudik, D., Runge, J., Salvat, D. J., Sander, J., Scholberg, K., Shakirov, A., Simakov, G., Snow, W. M., Sosnovtsev, V., Stringer, M., Subedi, T., Suh, B., Sur, B., Tayloe, R., Tellez-Giron-Flores, K., Tsai, Y. -T., van Nieuwenhuizen, E. E., Virtue, C. J., Visser, G., Walkup, K., Ward, E. M., Wongjirad, T., Yang, Y., Yoo, J., Yu, C. -H., Zaalishvili, A.
We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low
Externí odkaz:
http://arxiv.org/abs/2406.13806
Autor:
Barbeau, P. S., Belov, V., Bernardi, I., Bock, C., Bolozdynya, A., Bouabid, R., Browning, J., Cabrera-Palmer, B., Conley, E., da Silva, V., Daughhetee, J., Detwiler, J., Ding, K., Durand, M. R., Efremenko, Y., Elliott, S. R., Erlandson, A., Fabris, L., Febbraro, M., Galindo-Uribarri, A., Green, M. P., Hakenmüller, J., Heath, M. R., Hedges, S., Johnson, B. A., Johnson, T., Khromov, A., Konovalov, A., Kozlova, E., Kumpan, A., Kyzylova, O., Link, J. M., Liu, J., Major, A., Mann, K., Markoff, D. M., Mattingly, J., Mueller, P. E., Newby, J., Ogoi, N., O'Reilly, J., Parno, D. S., Pérez-Loureiro, D., Penttila, S. I., Pershey, D., Prior, C. G., Queen, J., Rapp, R., Ray, H., Razuvaeva, O., Reyna, D., Rich, G. C., Rudik, D., Runge, J., Salvat, D. J., Sander, J., Scholberg, K., Shakirov, A., Simakov, G., Snow, W. M., Sosnovtsev, V., Stringer, M., Subedi, T., Suh, B., Sur, B., Tayloe, R., Tellez-Giron-Flores, K., Tsai, Y. -T., Vanderwerp, J., van Nieuwenhuizen, E. E., Varner, R. L., Virtue, C. J., Visser, G., Walkup, K., Ward, E. M., Wongjirad, T., Yang, Y., Yoo, J., Yu, C. -H., Zaalishvili, A.
We consider the potential for a 10-kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model. Through a c
Externí odkaz:
http://arxiv.org/abs/2311.13032
Autor:
An, P., Awe, C., Barbeau, P. S., Becker, B., Belov, V., Bernardi, I., Bock, C., Bolozdynya, A., Bouabid, R., Brown, A., Browning, J., Cabrera-Palmer, B., Cervantes, M., Conley, E., Daughhetee, J., Detwiler, J., Ding, K., Durand, M. R., Efremenko, Y., Elliott, S. R., Fabris, L., Febbraro, M., Rosso, A. Gallo, Galindo-Uribarri, A., Germer, A. C., Green, M. P., Hakenmüller, J., Heath, M. R., Hedges, S., Hughes, M., Johnson, B. A., Johnson, T., Khromov, A., Konovalov, A., Kozlova, E., Kumpan, A., Kyzylova, O., Li, L., Link, J. M., Liu, J., Mahoney, M., Major, A., Mann, K., Markoff, D. M., Mastroberti, J., Mattingly, J., Mueller, P. E., Newby, J., Parno, D. S., Penttila, S. I., Pershey, D., Prior, C. G., Rapp, R., Ray, H., Raybern, J., Razuvaeva, O., Reyna, D., Rich, G. C., Ross, J., Rudik, D., Runge, J., Salvat, D. J., Sander, J., Scholberg, K., Shakirov, A., Simakov, G., Sinev, G., Skuse, C., Snow, W. M., Sosnovtsev, V., Subedi, T., Suh, B., Tayloe, R., Tellez-Giron-Flores, K., Tsai, Y. -T., Ujah, E., Vanderwerp, J., van Nieuwenhuizen, E. E., Varner, R. L., Virtue, C. J., Visser, G., Walkup, K., Ward, E. M., Wongjirad, T., Yoo, J., Yu, C. -H., Zawada, A., Zettlemoyer, J., Zderic, A.
Publikováno v:
Phys. Rev. Lett. 131, 221801 (2023)
Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino charged-current cross section on ${}^{127}$I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is
Externí odkaz:
http://arxiv.org/abs/2305.19594
Autor:
COHERENT Collaboration, An, P., Awe, C., Barbeau, P. S., Becker, B., Belling, S. W., Belov, V., Bernardi, I., Bock, C., Bolozdynya, A., Bouabid, R., Brown, A., Browning, J., Cabrera-Palmer, B., Cervantes, M., Conley, E., Daughhetee, J., Detwiler, J., Ding, K., Durand, M. R., Efremenko, Y., Elliott, S. R., Fabris, L., Febbraro, M., Rosso, A. Gallo, Galindo-Uribarri, A., Green, M. P., Hakenmüller, J., Heath, M. R., Hedges, S., Hughes, M., Johnson, B. A., Johnson, T., Khromov, A., Konovalov, A., Kozlova, E., Kumpan, A., Kyzylova, O., Li, L., Link, J. M., Liu, J., Major, A., Mann, K., Markoff, D. M., Mastroberti, J., Mattingly, J., Miller, K., Mueller, P. E., Newby, J., Parno, D. S., Penttila, S. I., Pershey, D., Prior, C. G., Rapp, R., Ray, H., Raybern, J., Razuvaeva, O., Reyna, D., Rich, G. C., Ross, J., Rudik, D., Runge, J., Salvat, D. J., Salyapongse, A. M., Sander, J., Scholberg, K., Shakirov, A., Simakov, G., Sinev, G., Snow, W. M., Sosnovtsev, V., Subedi, T., Suh, B., Tayloe, R., Tellez-Giron-Flores, K., Ujah, E., Vanderwerp, J., van Nieuwenhuizen, E. E., Varner, R. L., Virtue, C. J., Visser, G., Walkup, K., Ward, E. M., Wongjirad, T., Yoo, J., Yu, C. -H., Zettlemoyer, J.
Publikováno v:
Phys. Rev. D 108, 072001 (2023)
Using neutrinos produced at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL), the COHERENT collaboration has studied the Pb($\nu_e$,X$n$) process with a lead neutrino-induced-neutron (NIN) detector. Data from this detector
Externí odkaz:
http://arxiv.org/abs/2212.11295
Autor:
COHERENT Collaboration, Akimov, D., An, P., Awe, C., Barbeau, P. S., Becker, B., Belov, V., Bernardi, I., Blackston, M. A., Bock, C., Bolozdynya, A., Bouabid, R., Browning, J., Cabrera-Palmer, B., Chernyak, D., Conley, E., Daughhetee, J., Detwiler, J., Ding, K., Durand, M. R., Efremenko, Y., Elliot, S. R., Fabris, L., Febbraro, M., Rosso, A. Gallo, Galindo-Uribarri, A., Green, M. P., Heath, M. R., Hedges, S., Hoang, D., Hughes, M., Johnson, B. A., Johnson, T., Khromov, A., Konovalov, A., Kozlova, E., Kupman, A., Li, L., Link, J. M., Liu, J., Major, A., Mann, K., Markoff, D. M., Mastroberti, J., Mattingly, J., Mueller, P. E., Newby, J., Parno, D. S., Penttila, S. I., Pershey, D., Prior, C., Rapp, R., Ray, H., Razuvaeva, O., Reyna, D., Rich, G. C., Ross, J., Rudik, D., Runge, J., Salvat, D. J., Salyapongse, A. M., Sander, J., Scholberg, K., Shakirov, A., Simakov, G., Snow, W. M., Sosnovstsev, V., Suh, B., Tayloe, R., Tellez-Giron-Flores, K., Tolstukhin, I., Ujah, E., Vanderwerp, J., Varner, R. L., Virtue, C. J., Visser, G., Wongjirad, T., Yen, W. -R., Yoo, J., Yu, C. -H., Zettlemoyer, J.
We use data from the COHERENT CsI[Na] scintillation detector to constrain sub-GeV leptophobic dark matter models. This detector was built to observe low-energy nuclear recoils from coherent elastic neutrino-nucleus scattering. These capabilities enab
Externí odkaz:
http://arxiv.org/abs/2205.12414
Autor:
Akimov, D., Alawabdeh, S., An, P., Arteaga, A., Awe, C., Barbeau, P. S., Barry, C., Becker, B., Belov, V., Bernardi, I., Blackston, M. A., Blokland, L., Bock, C., Bodur, B., Bolozdynya, A., Bouabid, R., Bracho, A., Browning, J., Cabrera-Palmer, B., Chen, N., Chernyak, D., Conley, E., Daughhetee, J., Daughtry, J., Day, E., Coello, M. del Valle, Detwiler, J., Ding, K., Durand, M. R., Efremenko, Y., Elliott, S. R., Fabris, L., Febbraro, M., Fox, W., Galambos, J., Rosso, A. Gallo, Galindo-Uribarri, A., Gilbert, C., Green, M. P., Hansen, K. R., Harris, B., Heath, M. R., Hedges, S., Henderson, R., Hoang, D., Hughes, C., Hughes, M., Iverson, E., Jairam, P., Johnson, B. A., Johnson, T., Kaufman, L., Khromov, A., Konovalov, A., Koros, J., Kozlova, E., Kumpan, A., Li, L., Librande, J. T., Link, J. M., Liu, J., Major, A., Mann, K., Markoff, D. M., Mastroberti, J., Mattingly, J., McGoldrick, O., McIntyre, M., Melikyan, Y. A., Mishra, M., Mueller, P. E., Newby, J., Parno, D. S., Penne, A., Penttila, S. I., Pershey, D., Prior, C., Radford, D., Rahman, F., Rapp, R., Ray, H., Raybern, J., Razuvaeva, O., Reyna, D., Rich, G. C., Rimal, D., Ross, J., Rouzky, A., Rudik, D., Runge, J., Salvat, D. J., Salyapongse, A. M., Sander, J., Scholberg, K., Siehien, P., Shakirov, A., Simakov, G., Sinev, G., Snow, W. M., Sosnovstsev, V., Steele, J., Hjelmstad, A. Strasbaugh, Subedi, T., Suh, B., Tayloe, R., Tellez-Giron-Flores, K., Thornton, R. T., Tolstukhin, I., Trotter, S., Tsai, F., Tsai, Y. -T., Ujah, E., Vanderwerp, J., van Nieuwenhuizen, E., Varner, R. L., Vasquez, S., Virtue, C. J., Visser, G., Walkup, K., Wang, J., Ward, E. M., Wiseman, C., Wongjirad, T., Wu, D., Yang, J., Yang, Y., Yen, Y. -R., Yoo, J., Yu, C. -H., Zettlemoyer, J., Zhang, S.
The COHERENT experiment located in Neutrino Alley at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL), has made the world's first two measurements of coherent elastic neutrino-nucleus scattering (CEvNS), on CsI and argon, usi
Externí odkaz:
http://arxiv.org/abs/2204.04575
Autor:
Rahman, M., Mattingly, J.
Publikováno v:
In Nuclear Inst. and Methods in Physics Research, A September 2024 1066
Autor:
Mishra, M., Mattingly, J.
Multiplexing of radiation detector signals into a single channel significantly reduces the need for a large number of digitizer channels, which reduces the cost and the power consumption of a data acquisition system. We previously demonstrated freque
Externí odkaz:
http://arxiv.org/abs/2006.03597
Autor:
Weldon Jr., R. A., Mueller, J. M., Lynch, C., Schuster, P., Hedges, S., Awe, C., Li, L., Barbeau, P., Mattingly, J.
The scintillation light output response of stilbene crystals has been measured for protons recoiling along the \textit{a}, \textit{b}, and \textit{c'} crystalline axes with energies between 1.3 and 10 MeV using neutrons produced with the tandem Van d
Externí odkaz:
http://arxiv.org/abs/1906.02288
Publikováno v:
Nucl. Instrum. Meth. A 929 (2019) 57-65
Multiplexing of radiation detectors reduces the number of readout channels, which in turn reduces the number of digitizer input channels for data acquisition. We recently demonstrated frequency domain multiplexing (FDM) of pulse mode radiation detect
Externí odkaz:
http://arxiv.org/abs/1902.08665