Zobrazeno 1 - 10
of 20
pro vyhledávání: '"M.R.B. Tavakoli"'
Autor:
M.R.B. Tavakoli, Behrooz Vahidi
Publikováno v:
Journal of Electrical Engineering and Technology. 6:760-768
The performance of transmission lines and its shielding design during a lightning phenomenon are quite essential in the maintenance of a reliable power supply to consumers. The leader progression model, as an advanced approach, has been recently deve
Publikováno v:
IEEE Transactions on Power Systems. 26:775-782
The procedure for deriving the parameters of drum type boilers dynamic model for long-term transient stability studies by use of heat balance data is presented in this paper. The main purpose of the work is to exhibit a regular procedure using availa
Autor:
M.R.B. Tavakoli, Behrooz Vahidi
Publikováno v:
IEEE Transactions on Power Delivery. 26:507-516
In this paper, by creating a 3-D model of power-line equipment and lightning leader progression models, an alternate procedure for calculating the shielding failure rate (SFR) of transmission lines is presented. The stepping nature of lightning downw
Autor:
M.R.B. Tavakoli, Behrooz Vahidi
Publikováno v:
SIMULATION. 86:417-427
In this paper a novel method is presented to investigate lightning stroke attachment to earthed overhead transmission line structures. This method is based on the dynamic simulation of lightning downward leader movement toward the ground in three dim
Publikováno v:
IEEE Transactions on Power Systems. 24:1366-1374
In this paper, the parameters of Rowen's model for heavy duty gas turbines in dynamic studies are estimated by use of available operational and performance data. The work is aimed to create insight into various parts of the model and to introduce a s
Publikováno v:
IEEE Transactions on Power Delivery. 23:2201-2206
Shielding failure has long been recognized as a possible mode of lightning flashover. This paper reports the development of a method for estimating the shielding failure number of transmission lines using the charge simulation method. The effects of
Publikováno v:
IEEE Transactions on Power Systems. 22:1547-1553
In this paper, the procedure for deriving the parameters of an IEEE governor-turbine model (particularly turbine model) based on a practical study case consisting of a 200-MW tandem compound, single reheat steam unit and its available heat balance da
Publikováno v:
TENCON 2007 - 2007 IEEE Region 10 Conference.
Circuit breakers can fail to interrupt fault current when the power system has transient recovery voltage (TRV) characteristics that exceed the rating of circuit breaker. TRV is the voltage across the opening contacts of a fault interrupting circuit
Publikováno v:
2005 IEEE Russia Power Tech.
In industrial plant, severe failure may occur when motors operate through starting transformer. An industrial plant is simulated on ATP in the present paper and transient behavior during motor starting is investigated.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.