Zobrazeno 1 - 10
of 38
pro vyhledávání: '"M.L. Muga"'
Publikováno v:
Radiation Physics and Chemistry. 75:927-931
The design and fabrication of four types of miniature reference electrodes and their long term stability in a radiation field are described. Miniature versions of a saturated calomel electrode (MSCE), a silver/silver chloride electrode (MAG), a tungs
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 321:254-258
Little quantitative information is available regarding the ability of a thin film detector (TFD) to determine the nuclear charge of a low energy heavy mass ion. To compare the nuclear charge resolving power Z / ΔZ of the TFD to other heavy ion detec
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 320:471-478
A nuclear charged particle detector has been designed and fabricated at the University of Florida for use in identifying the nuclear charge Z and mass number A of low energy (∼1 MeV/amu) heavy mass ions. The detector consists of a stack of three se
Autor:
Andrew G. Weisenberger, J.E. McKisson, A. V. Ramayya, M.L. Muga, R.B. Piercey, Z. Milosevich, D.W. Ely, Stanislaw Majewski, P. Agnvall
Publikováno v:
IEEE Transactions on Nuclear Science. 37:148-151
The design and laboratory testing of a large-area, scintillation telescope (LAST) for the detection of heavy ions are discussed. This dual, thin-film detector is to be used as a fast event trigger, Delta E, and time-of-flight spectrometer at the foca
Publikováno v:
IEEE Conference on Nuclear Science Symposium and Medical Imaging.
A comparison has been made between two types of scintillators, NE-102, a commercial plastic scintillator, and paraterphenyl, a primary scintillator. The luminescence was measured by passing fission fragments through the films. The residual energy was
A three-stage thin-film detector for the identification of heavy ion fragments was investigated in beam at HHIRF. An experiment on Eu-152 for the purposes of calibrating a four-crystal Germanium polarimeter was performed. The instrument was then used
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::14de821ba05925dbee73acc711076243
https://doi.org/10.2172/10159530
https://doi.org/10.2172/10159530
Autor:
A. C. Rester, L.C. Dennis, P. S. Haskins, R.B. Piercey, CB Saw, J. D. Fox, RW Smart, M.L. Muga, R.L. Coldwell, F. E. Dunnam, Van Rinsvelt Ha, HJ Aarts
Publikováno v:
Physical Review C. 32:1897-1910
The reaction XGe( WO,2p2n)YSSr with E( WO) = 80 MeV was used to study the nucleus YSSr. Measurements were made of the excitation functions, angular distributions, and el-el-t coincidences. From these measurements six new levels were placed in the lev
Autor:
M.L. Muga, J.D. Bridges
Publikováno v:
Nuclear Instruments and Methods. 134:143-147
The specific luminescence ( ΔL / Δx ) of 0.5–8.8 MeV alpha particles from a natural decay source has been measured by using a thin film detector (TFD) consisting of a thin organic scintillator material positioned between and perpendicular to the
Autor:
M.L. Muga, Youhanna Fares
Publikováno v:
Nuclear Instruments and Methods in Physics Research. 193:513-520
A correlated (E−ΔE) double time-of-flight mass spectrometer was designed and used in the d E d x measurements of 235U fission fragments in nickel as a function of mass and energy. The system has a time resolution of 1 ns, a mass resolution of ΔML
Autor:
D.J. Burnsed, M.L. Muga
Publikováno v:
Nuclear Instruments and Methods. 150:183-187
A description is given of a compact, inexpensive and easily fabricated transmission detector of energetic heavy ions. The detector makes use of a crossed electric-magnetic field to guide electrons (ejected from a thin metallized film by a transiting