Effect of supply voltage harmonics on the input current of single-phase diode bridge rectifier loads
Publikováno v:
IEEE Transactions on Power Delivery. 10:1416-1422
This paper describes the effect of supply voltage harmonics on the response of single-phase capacitor-filtered diode bridge rectifier loads. A complete analytical model for calculating the current harmonics of these loads, when energized by nonsinuso
Publikováno v:
IEEE Transactions on Power Delivery. 10:1670-1676
This paper addresses the use of multiple active power line conditioners (APLCs) for holding harmonic voltages and voltage distortion in a power system within IEEE-519 guidelines while minimizing APLC injection current or several other alternative net
Publikováno v:
IEEE Transactions on Power Delivery. 10:2001-2006
In this paper we use the results of simulations to predict the net harmonic currents produced by large numbers of single-phase desktop computers in a facility, such as a commercial office building. We take into account attenuation due to system imped
Publikováno v:
IEEE Transactions on Power Delivery. 9:1531-1537
This paper addresses the use of an active power line conditioner (APCL) for holding voltage harmonics and voltage distortion within IEEE-519 guidelines at a set of power system busses. The following two related problems are solved: (1) what size APLC
Publikováno v:
IEEE Transactions on Power Delivery. 9:1639-1646
Variable speed motor drives produce nonsinusoidal currents and generate periodic magnetic fields with significant frequency content. This paper describes measuring techniques and an evaluation method to characterize the generated fields. The study in
Publikováno v:
IEEE Transactions on Power Delivery. 7:1379-1386
The impact of voltage harmonics on a power system can be minimized by using active filters to inject distortion-canceling currents. However, a network objective function must be specified before the optimum filter injection currents can be determined
Publikováno v:
IEEE Transactions on Energy Conversion. 7:580-588
The boiler on Southern California Edison's 750 MW Ormond Beach Unit 2 was extensively modified to reduce minimum load from 250 MW to 36 MW. With the unit operating at minimum load frequently at night, it became economically attractive to install adju
Publikováno v:
IEEE Transactions on Power Delivery. 6:1623-1628
The authors investigate nuisance tripping of adjustable-speed drives caused by capacitor switching on the utility distribution system. The authors discuss the basic phenomena and then present the results of sensitivity analysis simulations performed
Publikováno v:
IEEE Transactions on Power Delivery. 6:1690-1697
Active power line conditioner (APLC) is a type of active filter that compensates for power system waveform distortion. The objective is to develop and illustrate a procedure for calculating the APLC injection current needed to minimize voltage harmon
Publikováno v:
ICHPS V International Conference on Harmonics in Power Systems..