Zobrazeno 1 - 10
of 97
pro vyhledávání: '"M. de Saint Simon"'
Publikováno v:
The European Physical Journal A. 28:129-138
High-precision mass measurements have been performed on the exotic magnesium isotopes 29-33Mg using the MISTRAL radiofrequency spectrometer, especially suited for very short-lived nuclides. This method, combined with the powerful tool of resonant las
Autor:
Ismael Martel, H.-J. Kluge, A. Kohl, Dietrich Beck, M. König, F. Ames, J. Szerypo, E. Schark, Stefan Schwarz, Georg Bollen, R. B. Moore, Georges Audi, David Lunney, M. de Saint Simon, Frank Herfurth, H. Raimbault-Hartmann
Publikováno v:
Scopus-Elsevier
European Physical Journal A
European Physical Journal A, EDP Sciences, 2000, 8, pp.307-329
European Physical Journal A
European Physical Journal A, EDP Sciences, 2000, 8, pp.307-329
Direct mass measurements of neutron-deficient rare-earth isotopes in the vicinity of 146Gd were performed with the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. This paper reports on the measurement of more than 40 isotopes of the elements
Autor:
Georg Bollen, David Lunney, David B. Beck, R. B. Moore, F. Ames, H.-J. Kluge, Stefan Schwarz, E. Schark, Georges Audi, M. de Saint Simon, Ismael Martel, J. Szerypo, A. Kohl, M. König, H. Raimbault-Hartmann
Publikováno v:
ResearcherID
Nuclear Physics A
International Conference on Nuclear Physics at Storage Rings 3 Nuclear Physics at Storage Rings 3 Stori 96
International Conference on Nuclear Physics at Storage Rings 3 Nuclear Physics at Storage Rings 3 Stori 96, Sep 1996, Bernkastel-Kues, Germany. pp.343c-352c, ⟨10.1016/S0375-9474(97)00556-3⟩
Scopus-Elsevier
Nuclear Physics A
International Conference on Nuclear Physics at Storage Rings 3 Nuclear Physics at Storage Rings 3 Stori 96
International Conference on Nuclear Physics at Storage Rings 3 Nuclear Physics at Storage Rings 3 Stori 96, Sep 1996, Bernkastel-Kues, Germany. pp.343c-352c, ⟨10.1016/S0375-9474(97)00556-3⟩
Scopus-Elsevier
Direct mass measurements of neutron deficient rare earth isotopes in the vicinity of 146 Gd were performed for the first time with the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. Since ISOL-facilities deliver these isotopes with a large a
Autor:
Georges Audi, C. Bachelet, David Lunney, C. Guénaut, C. Thibault, M. de Saint Simon, M. Sewtz, C. Gaulard
Publikováno v:
Nuclear Physics A
Nuclear Physics A, Elsevier, 2009, 826, pp.1-23. ⟨10.1016/j.nuclphysa.2009.04.011⟩
Nuclear Physics A, Elsevier, 2009, 826, pp.1-23. ⟨10.1016/j.nuclphysa.2009.04.011⟩
The mass of the halo nuclide (11)Li has been measured with unprecedented precision with the MISTRAL mass spectrometer at CERN's ISOLDE facility. Its resulting two-neutron separation energy, S(2n) = 378 +/- 5 keV, is 25% higher than the previously acc
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5bf13f71c3704718e3fcc55f8faad269
http://hal.in2p3.fr/in2p3-00684873
http://hal.in2p3.fr/in2p3-00684873
Autor:
C. Bachelet, G. Audi, C. Guénaut, C. Gaulard, C. Thibault, D. Lunney, F. Herfurth, M. de Saint Simon
Publikováno v:
Physical Review Letters
Physical Review Letters, American Physical Society, 2008, 100, pp.182501. ⟨10.1103/PhysRevLett.100.182501⟩
Physical Review Letters, American Physical Society, 2008, 100, pp.182501. ⟨10.1103/PhysRevLett.100.182501⟩
The extended radius of a halo nuclide is very sensitive to the minute binding energy of its valence nucleons. The binding energy of {sup 11}Li has been measured with high precision by using the radio-frequency spectrometer MISTRAL at CERN's ISOLDE fa
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::8107adcc145be9b28cb2a9a5433623ad
http://hal.in2p3.fr/in2p3-00854520
http://hal.in2p3.fr/in2p3-00854520
Publikováno v:
International Journal of Mass Spectrometry
International Journal of Mass Spectrometry, Elsevier, 2006, 251, pp.286-292. ⟨10.1016/j.ijms.2006.02.007⟩
International Journal of Mass Spectrometry, Elsevier, 2006, 251, pp.286-292. ⟨10.1016/j.ijms.2006.02.007⟩
Dedicated to H.-J. Kluge on the occasion of his 65th birthday anniversary - Jürgen Kluge Special Issue; At Princeton in the 1960's, L.G. Smith invented an instrument of astonishing accuracy and rapid measurement time, derived from his so-called mass
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::2c40e3e67dd6cc561c36d34846571a5d
http://hal.in2p3.fr/in2p3-00026027
http://hal.in2p3.fr/in2p3-00026027
Autor:
C. Guénaut, C. Gaulard, G. Audi, C. Bachelet, M. de Saint Simon, C. Thibault, N. Vieira, D. Lunney, F. Herfurth
Publikováno v:
Exotic Nuclei Exon2004.
Autor:
C. Gaulard, C. Bachelet, David Lunney, C. Thibault, C. Guénaut, M. de Saint Simon, Georges Audi, Frank Herfurth
Publikováno v:
The 4th International Conference on Exotic Nuclei and Atomic Masses ISBN: 9783540284413
European Physical Journal A
ENAM 04 The Fourth International Conference on Exotic Nuclei and Atomic Masses
ENAM 04 The Fourth International Conference on Exotic Nuclei and Atomic Masses, Sep 2004, Pine Mountain, Georgia, United States. pp.31-32, ⟨10.1140/epjad/i2005-06-005-5⟩
European Physical Journal A
ENAM 04 The Fourth International Conference on Exotic Nuclei and Atomic Masses
ENAM 04 The Fourth International Conference on Exotic Nuclei and Atomic Masses, Sep 2004, Pine Mountain, Georgia, United States. pp.31-32, ⟨10.1140/epjad/i2005-06-005-5⟩
A direct mass measurement of the very-short-lived halo nuclide $^{11}$Li (T$_{1/2}$ = 8.7 ms) has been performed with the transmission mass spectrometer MISTRAL. The preliminary result for the two-neutron separation energy is S$_{2n}$ = 376$\pm$ 5 ke
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ce38da01abace63e492515ef93061a90
https://doi.org/10.1007/3-540-37642-9_6
https://doi.org/10.1007/3-540-37642-9_6
Autor:
M. de Saint Simon, H. Deitinghoff, H. Vormann, Alwin Schempp, A. Firjahn-Andersch, F. Botlo-Pilat, J.Y. Hemery, C. Thibault
Publikováno v:
Conference record of the 1991 IEEE particle accelerator conference Accelerator science and technology-vol 5
1991 Institute of Electrical and Electronics Engineers (IEEE) Particle Accelerator Conference (PAC)
1991 Institute of Electrical and Electronics Engineers (IEEE) Particle Accelerator Conference (PAC), May 1991, San Francisco, United States. pp.3041-3043
1991 Institute of Electrical and Electronics Engineers (IEEE) Particle Accelerator Conference (PAC)
1991 Institute of Electrical and Electronics Engineers (IEEE) Particle Accelerator Conference (PAC), May 1991, San Francisco, United States. pp.3041-3043
A 4-rod-RFQ (radio-frequency quadrupole) has been built for the deceleration of antiprotons which will be extracted from LEAR at 2.0 MeV and injected at 0.2 MeV into the RF-mass spectrometer built by CSNSM, Orsay, for the high-precision mass comparis
Autor:
G. Audi, C. Gaulard, S. Henry, N. Vieira, C. Monsanglant, D. Lunney, H. Doubre, G. Bollen, C. Thibault, C. Toader, M. de Saint Simon, C. Borcea
Publikováno v:
Nuclear Physics in the 21st Century
International Nuclear Physics Conference INPC 2001
International Nuclear Physics Conference INPC 2001, Jul 2001, Berkeley, United States. pp.910-914
International Nuclear Physics Conference INPC 2001
International Nuclear Physics Conference INPC 2001, Jul 2001, Berkeley, United States. pp.910-914
The MISTRAL experiment (Mass measurements at ISOLDE/CERN with a Transmission and Radiofrequency spectrometer on-Line), is well suited for mass determination of very short-lived nuclides. Masses are determined by measuring the cyclotron frequency of a