Zobrazeno 1 - 10
of 59
pro vyhledávání: '"M. Zielczynski"'
Autor:
M. Zielczynski, N. Golnik
Publikováno v:
Radiation Protection Dosimetry. 52:35-38
A novel method is presented for the determination of the energy loss distribution in the nanometric region from the initial recombination of ions in high pressure ionisation chambers. Low resolution distributions can be obtained by comparison of satu
Autor:
N. Golnik, M. Zielczynski
Publikováno v:
Radiation Protection Dosimetry. 44:57-60
Autor:
M. Zielczynski, N. Golnik
Publikováno v:
2007 IEEE Nuclear Science Symposium Conference Record.
The work deals with the problem of the ambient dose equivalent measurements in high energy neutron fields by means of recombination ionization chamber. The method is based on the measurements of the absorbed dose and the recombination index of radiat
Publikováno v:
2006 IEEE Nuclear Science Symposium Conference Record.
An ionization chamber, filled with 10BF3 and operating in a pulse mode was investigated as a possible pocket detector for detection of neutrons at low flux densities. The chamber is 85 mm long and 19 mm in diameter. The measured sensitivity of the ch
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
Physics in Medicine and Biology. 33:1055-1064
The twin-detector method was applied to determine the A-150 plastic kerma components in a 19 MeV mixed neutron-photon field in free-air. High-pressure ionisation chambers and thimble-type ionisation chambers at normal pressure were used. The spectral
Publikováno v:
Radiation Protection Dosimetry. 23:273-276
The concept of the recombination index of quality (RIQ) is based on the degree of initial recombination and was introduced to provide a measurable quantity of radiation quality. The RIQR values can be determined employing a high pressure ionisation c
Publikováno v:
ResearcherID
A system for low-level dosimetry is proposed, It contains a recombination chamber with specially designed electronic circuit. Polarizing electrodes of recombination chamber of REM-2 type are supplied from capacitors permanently connected to the elect
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::abc6f16e7de3a0491940253a0078279e
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=ORCID&SrcApp=OrcidOrg&DestLinkType=FullRecord&DestApp=WOS_CPL&KeyUT=WOS:000166896300907&KeyUID=WOS:000166896300907
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=ORCID&SrcApp=OrcidOrg&DestLinkType=FullRecord&DestApp=WOS_CPL&KeyUT=WOS:000166896300907&KeyUID=WOS:000166896300907
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.