Publikováno v:
IEEE Transactions on Nuclear Science. 23:501-506
The image intensifier tube opens a new era in scintigraphic diagnosis. The first results are very promising. Because of the image quality, tumors can be detected earlier than with other systems, and more details can be perceived. In the future the qu
Publikováno v:
IEEE Transactions on Nuclear Science. 28:60-63
Two years ago, a gamma camera detector, consisting of a 34 cm input field image intensifier coupled to a scintillator crystal at the input and to a silicon localizer at the output, was built and tested at Thomson-CSF. Snce that time the 34-cm model h
Autor:
M. Verat, H. Rougeot
Publikováno v:
SPIE Proceedings.
We describe the basic structure and the making process of radiation-sensitive image-converter-tubes ; these tubes are self-sensitive for 10 kev to 10 Mev photons or cold and thermal neutrons. In most general use, these tubes have an affective field a
Publisher Summary This chapter examines the improvements to an image intensifier for a γ-ray scintillation camera. A 35 cm input field image intensifier tube designed for scintillation cameras was described at the Fifth Symposium on Photo-Electronic
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::75c325324891ef0c8a2a6fc0d75e5e7d
https://doi.org/10.1016/s0065-2539(08)61459-6
https://doi.org/10.1016/s0065-2539(08)61459-6
Publikováno v:
SPIE Proceedings.
Many general vascular examinations require a large field of view. For this purpose, a new 16" X-ray image intensifier has been developed incorporating most recent technologies. In operation, the radiologist will appreciate its useful view of over 36
Publikováno v:
Neutron Radiography ISBN: 9789400970458
The most frequently used techniques in neutron radiography employ a neutron converter consisting of either a scintillator or a thin metal sheet. The radiation created by the neutrons exposes a photographic film that is in contact with the converter :
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::c821e51a99e55f395653b46f1195e030
https://doi.org/10.1007/978-94-009-7043-4_72
https://doi.org/10.1007/978-94-009-7043-4_72
Publisher Summary This chapter describes the various aspects of a 35-cm input-field image intensifier for scintillation cameras. A 35-cm input-field image intensifier tube is designed for use in scintillation cameras having high spatial and energy re
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::1a3d9d6234d5a867cea237155e1001c6
https://doi.org/10.1016/s0065-2539(08)60813-6
https://doi.org/10.1016/s0065-2539(08)60813-6
Kniha
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Kniha
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.