Zobrazeno 1 - 10
of 16
pro vyhledávání: '"M. N. Kinnane"'
Publikováno v:
Metrologia. 52:244-250
We describe a simple method for high-precision rotary angle encoder calibration for long-range angular errors. By using a redesigned electronic nulling autocollimator, an optical-polygon artifact is calibrated simultaneously with determining the enco
Autor:
Endre Takacs, Christopher T. Chantler, Joshua M. Pomeroy, L. F. Smale, Albert Henins, John D. Gillaspy, Joseph N. Tan, Lawrence T. Hudson, B. Radics, M. N. Kinnane, Csilla I. Szabo, J. A. Kimpton
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 580:246-249
A new data acquisition system coupled to a backgammon-type gas proportional counter capable of single-photon counting over a wide range of count rates has been developed and replaces a CAMAC-based system. The new apparatus possesses improved architec
Publikováno v:
Radiation Physics and Chemistry. 75:1744-1748
The electron beam ion trap has opened the door for experimental physics to perform critical tests of bound state QED in the medium- Z regime. The relatively small uncertainties associated with the theoretical predictions necessitate highly accurate e
Publikováno v:
Measurement Science and Technology. 16:2280-2286
Two-dimensional backgammon configuration and multiwire gas proportional counters have been in use for decades in the field of x-ray physics for high-precision or high-flux experiments. Systematics inherent to this type of detector lead to image disto
Autor:
K. Makonyi, Albert Henins, A T Payne, John D. Gillaspy, Lawrence T. Hudson, J. A. Kimpton, Joshua M. Pomeroy, M. N. Kinnane, Endre Takacs, Christopher T. Chantler, L. F. Smale
Publikováno v:
Physical Review Letters. 110
Publikováno v:
Physical Review A. 87
Characteristic radiation is used extensively in most high-accuracy x-ray experiments as a standard for calibration, both in laboratory physics and in astrophysics. $K\ensuremath{\alpha}$ and $K\ensuremath{\beta}$ radiations have complex asymmetric st
Autor:
Joseph N. Tan, Endre Takacs, Lawrence T. Hudson, Christopher T. Chantler, L. F. Smale, John D. Gillaspy, Joshua M. Pomeroy, Albert Henins, M. N. Kinnane, A T Payne, K. Makonyi, J. A. Kimpton
Publikováno v:
Physical Review Letters. 109
We report a new test of quantum electrodynamics (QED) for the w (1s2p(1)P(1)→1s(2)(1)S(0)) x-ray resonance line transition energy in heliumlike titanium. This measurement is one of few sensitive to two-electron QED contributions. Systematic errors
Autor:
C T, Chantler, M N, Kinnane, J D, Gillaspy, L T, Hudson, A T, Payne, L F, Smale, A, Henins, J M, Pomeroy, J N, Tan, J A, Kimpton, E, Takacs, K, Makonyi
Publikováno v:
Physical review letters. 109(15)
We report a new test of quantum electrodynamics (QED) for the w (1s2p(1)P(1)→1s(2)(1)S(0)) x-ray resonance line transition energy in heliumlike titanium. This measurement is one of few sensitive to two-electron QED contributions. Systematic errors
Autor:
Joshua M. Pomeroy, Lawrence T. Hudson, Joseph N. Tan, Endre Takacs, M. N. Kinnane, John D. Gillaspy, B. Radics, Christopher T. Chantler, L. F. Smale, Csilla I. Szabo, J. A. Kimpton
We report here our methods and results of measurements of very low-signal X-ray spectra produced by highly charged ions in an electron beam ion trap (EBIT). A megapixel Si charge-coupled device (CCD) camera was used in a direct-detection, single-phot
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::114809ce42c7e62fbd86ed66c53c3e78
Publikováno v:
Physical Review A. 73
In most high-accuracy x-ray experiments, characteristic radiation is used to determine calibration energies or wavelengths. This paper presents experimental results for vanadium $K\ensuremath{\alpha}$, and component refitting for scandium, titanium,