Autor:
Virginia Tsapaki, Sofia Kottou, Vasileios Chatzoglou, Dimitrios Nikolopoulos, Ioannis Papailiou, M. Molfetas
Publikováno v:
OMICS Journal of Radiology. 5
Introduction: Computed Tomography (CT) produces high quality diagnostic images at the expense of increased radiation dose compared to routine radiographic examinations. The dose from the CT examinations can be reduced by controlling certain scanning
Publikováno v:
OMICS Journal of Radiology.
Introduction: Radiation exposure from Computed Tomography (CT) examinations remains a concern due to the high doses it is associated with. In this study over 1000 patients’ dose information was collected from 11 CT scanners in Greece to evaluate th
Autor:
Sofia Kottou, Charalambos Vassilopoulos, Caliope Alevizaki, Barbara Vlassopoulou, Phoedi Rondogianni, Maria Alevizaki, Valsamis Hadjiconstantinou, Alexandros Samartzis, M. Molfetas
Publikováno v:
Scopus-Elsevier
Iodine 131 ablation following total thyroidectomy is considered an indispensable element of successful treatment of differentiated thyroid carcinoma (Dtc). because of the essential role of the kidneys in iodine clearance, (131)I therapy of Dtc in pat
Autor:
Sofia Kottou, E. Charou, O. Benekos, Nikolaos Kelekis, M. Molfetas, Stylianos Argentos, Efstathios P. Efstathopoulos
Publikováno v:
Radiation Protection Dosimetry. 117:291-297
Image viewing and processing software in computed radiography manipulates image contrast in such a way that all relevant image features are rendered to an appropriate degree of visibility, and improves image quality using enhancement algorithms. The
Autor:
D. Origgi, Giampiero Tosi, Sofia Kottou, A. Manetou, M. Molfetas, D. Papadimitriou, S. Vigorito, N. Panagiotakis, K. Hourdakis, A. Perris, M. Lyra-Georgosopoulou
Publikováno v:
Scopus-Elsevier
A survey of examination frequencies, dose reference values, effective doses and doses to organs involving 14 scanners from Greece and 32 scanners from Italy was carried out for the years 1999 and 2000. Examination frequencies per scanner and per year
Autor:
D. Papadimitriou, A. Manetou, J. Vassileva, A. Perris, M. Molfetas, N. Panagiotakis, G. Tsourouflis, Sofia Kottou, P. Chronopoulos, O. Karapanagiotou
Publikováno v:
Radiation Protection Dosimetry. 95:43-48
The radiographic technique factors and the quality of each radiographic image for three common examinations (chest PA, pelvis AP and lumbar spine LAT) were compared with the European criteria and entrance surface dose (ESD) was measured for each radi
Publikováno v:
Scopus-Elsevier
Personnel of haemodynamic and interventional radiology units receive continuously increasing radiation doses due to extended fluoroscopy. Moreover, there is not a parallel increase in the number of cardiology specialists involved. Doses received by 1
Publikováno v:
Radiation protection dosimetry. 158(3)
Four hundred and ninety-five adult patients in 16 medical centres participated in this study aiming to investigate the congruence between the volume CT dose index (CTDIvol) monitor values and measured ones during common CT procedures, performed by 20
Publikováno v:
Radiation Protection Dosimetry. 57:293-296
Publikováno v:
Radiation protection dosimetry. 153(2)
Combined tube current modulation techniques (such as Care Dose4D used in this study) during computed tomography (CT) procedures bring together the benefits of the angular and z-axis modulation techniques, measuring X-ray attenuation profile in the z-