Zobrazeno 1 - 10
of 10
pro vyhledávání: '"M. M. Ahasan"'
Autor:
M A Samad, M. M. Ahasan, R. Khatun, Md. Ashikur Rahman, R Mallick, M. Ohiduzzaman, Shirin Akter, Muhammad Abdul Kadir, M M Billah, Selim Reza, M. F. Uddin
Publikováno v:
Universal Journal of Public Health. 7:201-206
Thyroid uptake and scintigraphy using Tc-99m pertechnetate has proven to be more advantageous than with I-131 iodide, since the images have better quality, the procedure is faster and the patient is submitted to a lower radiation dose. Tc-99m has bee
Autor:
M. A. Rahaman, R. A. Sharmin, M. M. Rahman, H. M. Jamil, Shirin Akter, A. N. Monika, R. Khatun, M. F. Uddin, Rasel Das, M. M. Ahasan
Publikováno v:
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology. :1-8
High resolution (4 mm) tof PET-CT (positron emission tomography-computed tomography) from Philips of model Ingenuity TF is newly installed at Institute of Nuclear Medical Physics (INMP). 128 slice CT component incorporated with PET provides comparati
Autor:
M. R. Islam, A. N. Monika, Shirin Akter, H. M. Jamil, M. F. Uddin, M. M. Ahasan, Md. Ashikur Rahman, M. M. Rahman, Rasel Das, R. Khatun, R. A. Sharmin, M. N. Khanam
Publikováno v:
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology. :46-56
Image contrast recovery coefficient (CRC) of a large ring PET scanner “macroPET” was studied with septa and without septa configuration by ac-quiring data from a laboratory made 35.7 cm square phantom filled with 18-F. Images were reconstructed w
Autor:
H. M. Jamil, Md. Ashikur Rahman, R. Khatun, M. F. Uddin, Shirin Akter, A. N. Monika, M. M. Ahasan
Publikováno v:
Universal Journal of Medical Science. 5:27-31
High energy medical linac from Varian Medical Systems of model Clinac iX is installed in Bangladesh Atomic Energy Commission with dual photon energies (15 MV and 6 MV) and five electron energies upto 18 MeV. This machine is used to treat cancer patie
Autor:
Shirin Akter, A. N. Monika, M. N. Khanam, R. Khatun, M. M. Ahasan, M. F. Uddin, Md. Ashikur Rahman
Publikováno v:
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology. :208-215
Image noise analysis of a large ring PET scanner “macro PET” performed using two different phantoms, namely a Jaszczak SPECT phantom and a uniform cylindrical phantom. In the present work, simple 2D filtered back projection was used to reconstruc
Autor:
Shirin Akter, R. Khatun, M. N. Khan, S. M. M. Islam, T. A. Biman, A. N. Monika, M. M. Ahasan, M. F. Uddin
Publikováno v:
Universal Journal of Medical Science. 4:65-68
Dual Energy X-ray Absorptiometry (DXA) has long been and remains the most widely used technique for Bone Mineral Densitometry (BMD) measurement. Several manufacturers developed their performance of DXA with various types of measurement software but s
Publikováno v:
Jahangirnagar University Environmental Bulletin. 2:1-8
Rajbari district of Bangladesh, have been studied and possible health effect were estimated. The experiment has been done by using gamma ray spectrometry system consisting of a HPGe detector coupled with MCA and associate electronics. The average nat
Publikováno v:
TAJ: Journal of Teachers Association. 16:54-57
A retrospective study has been conducted on 19 patients who attended at CNMU, Rajshahi withdifferentiated thyroid cancer, treated with radioiodine for ablation of residual tissue afterthyroidectomy. The patients included in this study were between 06
Publikováno v:
TAJ: Journal of Teachers Association. 16:65-67
The study was carried out with an aim to make a correlation between radionuclide renographyand biochemical test in the evaluation of renal diseases. A total of 275 patients with a history oflow back pain were included in the study. Radionuclide renog
Autor:
Nazrul Islam SK; Institute of Nutrition and Food Science, University of Dhaka, Dhaka-1000, Bangladesh. snislam@bangla.net, Gray AI, Waterman PG, Ahasan M
Publikováno v:
Phytotherapy research : PTR [Phytother Res] 2002 Nov; Vol. 16 (7), pp. 672-4.