Zobrazeno 1 - 10
of 114
pro vyhledávání: '"M. Ebine"'
Autor:
Ryoji Kiyanagi, Kentaro Toh, Tatsufumi Nakamura, T. Koizumi, Kaoru Sakasai, M. Ebine, Takashi Ohhara
Publikováno v:
2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).
Two-dimensional neutron detectors were developed for the extension of SENJU time-of-flight Laue single crystal neutron diffractometer in J-PARC MLF. The detectors are installed at the additional detector bank for the SENJU instrument. The detector mo
Publikováno v:
2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).
A large area, position-sensitive scintillation neutron detector was developed for upgrading the SENJU, a time-of-flight Laue single crystal neutron diffractometer, in J-PARC MLF. The detector has a neutron-sensitive area of 512 × 512 mm with a pixel
Autor:
M. Ebine, A. Birumachi, Takuro Kawasaki, Tatsufumi Nakamura, Kentaro Toh, Tsutsui Noriaki, Kaoru Sakasai
Publikováno v:
2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS/MIC).
A two-dimensional scintillation neutron detector with a submillimeter spatial resolution was developed for time-of-flight neutron diffraction imaging in the J-PARC MLF. The detector comprised the thin, single ZnS/6LiF scintillator screen coupled with
Autor:
Michio Seya, Tatsufumi Nakamura, Akira Ohzu, H. Suzuki, Masatoshi Kureta, A. Birumachi, M. Ebine, K. Honda, Kentaro Toh, H. Yamagishi, M. Takase, Hironobu Nakamura, Mitsuo Haruyama, Kazuhiko Soyama, Kaoru Sakasai
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 763:340-346
A neutron-sensitive ZnS/10B2O3 ceramic scintillator detector was developed as an alternative to a 3He-gas-based detector for use in a plutonium canister assay system. The detector has a modular structure, with a flat ZnS/10B2O3 ceramic scintillator s
Autor:
M. Katagiri, K. Honda, H. Suzuki, Kentaro Toh, Kaoru Sakasai, Tatsufumi Nakamura, M. Ebine, Kazuhiko Soyama, A. Birumachi
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 741:42-46
A position-sensitive tubular scintillator-based neutron detector is proposed as an alternative to a 3 He-gas-based detector. The detector has a neutron-detecting element constructed from rolled ZnS/ 6 LiF scintillator screens that sandwich wavelength
Autor:
A. Birumachi, M. Katagiri, Kazuhiko Soyama, Kentaro Toh, Takuro Kawasaki, M. Ebine, K. Honda, H. Suzuki, Kaoru Sakasai, Tatsufumi Nakamura
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 737:176-183
A scintillator-based neutron-counting imaging detector with a sub-100-μm spatial resolution was developed for energy-selective neutron imaging. The detector head of the detector comprised a thin ZnS/6LiF scintillator screen, a fibre-optic taper and
Autor:
Ryoji Kiyanagi, Kentaro Toh, M. Ebine, Kaoru Sakasai, Takashi Ohhara, Takaaki Hosoya, Tatsufumi Nakamura, Kenichi Oikawa, M. Katagiri, Takuro Kawasaki, Kazuhiko Soyama, A. Birumachi
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 735:444-451
The detector system of SENJU —a single-crystal time-of-flight neutron diffractometer—is described. SENJU is the first diffractometer employing a large-area two-dimensional wavelength-shifting fiber-based scintillator detector at the Materials and
Publikováno v:
2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD).
We have developed a position-sensitive tubular scintillation neutron detector as an alternative to a 3He gas based detector. The detector comprises a number of individual neutron-sensitive elements, where a pair of wound wavelength-shifting fiber coi
Publikováno v:
2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).
A two-dimensional scintillation neutron detector that has neutron-sensitive area of 64 × 64 cm2 was developed for thermal neutron scattering instruments. The detector extensively used ZnS scintillation screens doped with 10B or 6Li and wavelength sh
Publikováno v:
Journal of Instrumentation. 12:C12025-C12025
A high-spatial-resolution, large-area position-sensitive scintillation-based neutron detector module has been developed for a new time-of-flight Laue single-crystal diffractometer to be constructed at J-PARC MLF. A first prototype detector implementi