Zobrazeno 1 - 9
of 9
pro vyhledávání: '"M. B. Greiter"'
Publikováno v:
Radiation Protection Dosimetry. 187:438-450
Radiation qualities were characterised and validated at the fully automated X-ray calibration facility of the Individual Monitoring Service at Helmholtz Zentrum München by using half-value layer and Hp(10) dosimetry approaches specified in the updat
Publikováno v:
Radiat. Prot. Dosim. 185, 222-230 (2019)
The individual monitoring service at the Helmholtz Zentrum München is currently developing a new eye lens dosemeter to be integrated in radiation protection glasses and a new ring dosemeter using a new BeOSL detector element for extremity dosimetry
Publikováno v:
Radiation Protection Dosimetry. 184:73-78
The individual monitoring service at the Helmholtz Zentrum München has extended the calibration facilities provided at the Munich IAEA/WHO secondary standard dosimetry laboratory with a new fully automated X-ray calibration facility for the calibrat
Autor:
M. Furlan, M. Figel, P. Kleinau, E. Mende, J. Brönner, H. Hoedlmoser, M. Schmid, M B Greiter, P. Scheubert, T. Haninger, V. Bandalo, R. Esser
Publikováno v:
Radiat. Meas. 125, 106-115 (2019)
With the annual dose limit for the lens of the eye being lowered to 20 mSv from 2019, both new efforts to improve radiation protection for this part of the body and new approved dosemeters for official dose monitoring are required. The individual mon
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::9b6d1377c7d94f550264c6fc1e5cd501
https://push-zb.helmholtz-muenchen.de/frontdoor.php?source_opus=56129
https://push-zb.helmholtz-muenchen.de/frontdoor.php?source_opus=56129
Autor:
R. Esser, T. Haninger, H. Hoedlmoser, E. Mende, V. Bandalo, P. Scheubert, M B Greiter, J. Brönner, M. Emmerl, P. Kleinau, M. Figel
Publikováno v:
Radiation Measurements. 132:106258
To extend the applications of BeOSL technology beyond whole body dosimetry, three new dosemeters were developed: an eye lens dosemeter and a finger ring dosemeter using a single BeOSL detector element and a two-element area dosemeter for work place m
Autor:
H. Hoedlmoser, M. Furlan, V. Bandalo, M. Figel, M. Schmid, J. Brönner, R. Eßer, P. Scheubert, I. Strobel, P. Kleinau, T. Haninger, M B Greiter, E. Mende
Publikováno v:
Radiat. Meas. 131:106235 (2020)
A new BeOSL eye lens dosemeter for integration in radiation protection glasses has been investigated in laboratory tests on an Alderson head phantom. Several dosemeter positions on an unshielded Alderson phantom were exposed in the primary x-ray beam
Autor:
V. Bandalo, E. Mende, H. Hoedlmoser, M. Emmerl, M B Greiter, P. Scheubert, R. Esser, P. Kleinau, T. Haninger, J. Brönner, M. Figel
Publikováno v:
Radiation Measurements. 131:106234
The Individual Monitoring Service (IMS) at the Helmholtz Zentrum Munchen together with Dosimetrics GmbH has developed and characterized a new ring dosemeter for photon radiation for the measurement of Hp(0,07), based on BeOSL technology. This work de
Publikováno v:
Radiation protection dosimetry. 170(1-4)
The individual monitoring service at the Helmholtz Zentrum Munchen has adopted the recommendations of the ISO 4037 and 6980 standards series as base of its dosimetric systems for X-ray, gamma and beta dosimetry. These standards define technical requi
Publikováno v:
IFMBE Proceedings ISBN: 9783642039010
Imaging plates commonly replace analogue film in radiography, yet not in individual monitoring. One reason for this is the temporal instability of the optically stimulated luminescence signal over prolonged storage time, termed ‘fading’.
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::ba3f0de6acc109d6a171328ebbd655c7
https://doi.org/10.1007/978-3-642-03902-7_105
https://doi.org/10.1007/978-3-642-03902-7_105