Zobrazeno 1 - 10
of 43
pro vyhledávání: '"M. A. Balvin"'
Autor:
Stephen J. Smith, Wonsik Yoon, Archana M. Devasia, Peter C. Nagler, Thomas R. Stevenson, Simon R. Bandler, Kevin Ryu, M. A. Balvin
Publikováno v:
Journal of Low Temperature Physics. 199:916-922
We describe the performance of position-sensitive metallic magnetic calorimeter X-ray detectors for potential future astrophysics missions, such as Lynx. The motivation behind this is to achieve a large focal plane area by increasing the number of pi
Autor:
Stephen J. Smith, Thomas R. Stevenson, Vladimir Bolkhovsky, Peter C. Nagler, Wonsik Yoon, Simon R. Bandler, Archana M. Devasia, Kevin Ryu, M. A. Balvin
Publikováno v:
IEEE Transactions on Applied Superconductivity. 29:1-6
Future astrophysics missions such as the Lynx X-ray Microcalorimeter will comprise a very large array of X-ray microcalorimeters with greater than 100 000 pixels. One of the major challenges associated with the realization of large format arrays is t
Design and Performance of a Prototype Magnetic Calorimeter Array for the Lynx X-Ray Microcalorimeter
Autor:
Stephen J. Smith, Peter C. Nagler, Wonsik Yoon, M. A. Balvin, Simon R. Bandler, Kevin Ryu, Archana M. Devasia, Thomas R. Stevenson
Publikováno v:
IEEE Transactions on Applied Superconductivity. 29:1-6
We describe a small-scale demonstration of an X-ray microcalorimeter using metallic magnetic calorimeters (MMCs) that consist of superconducting meander-shaped sensor coils with very fine pitches. These devices are being developed for potential futur
Autor:
Stephen J. Smith, Simon R. Bandler, Wonsik Yoon, Archana M. Devasia, M. A. Balvin, Thomas R. Stevenson, Peter C. Nagler
Publikováno v:
Journal of Low Temperature Physics. 193:668-674
We describe prototype arrays of magnetically coupled microcalorimeters fabricated with an approach scalable to very large format arrays. The superconducting interconnections and sensor coils have sufficiently low inductance in the wiring and sufficie
Autor:
Stephanie Getty, Jamie E. Elsila, John G. Hagopian, Carl A. Kotecki, Larry Hess, William B. Brinckerhoff, Andrej Grubisic, Timothy J. Cornish, Lucy F. Lim, Jerome Ferrance, Xiang Li, M. A. Balvin, Adrian E. Southard
Publikováno v:
Micro- and Nanotechnology Sensors, Systems, and Applications XI.
A number of new instrument capabilities are currently in maturation for future in situ use on planetary science missions. Moving beyond the impressive in situ instrumentation already operating in planetary environments beyond Earth will enable the ne
Autor:
Jerome Ferrance, Jamie E. Elsila, Adrian E. Southard, Andrej Grubisic, Stephanie Getty, Xiang Li, Timothy J. Cornish, M. A. Balvin, William B. Brinckerhoff
Publikováno v:
2017 IEEE Aerospace Conference.
The Molecular Analyzer for Complex Refractory Organic-rich Surfaces, MACROS, is a novel instrument package being developed at NASA Goddard Space Flight Center. MACROS enables the in situ characterization of a sample's composition by coupling two powe
Autor:
Thomas R. Stevenson, Kevin Ryu, Simon R. Bandler, Wonsik Yoon, Stephen J. Smith, Archana M. Devasia, M. A. Balvin, Peter C. Nagler
Publikováno v:
Journal of Astronomical Telescopes, Instruments, and Systems. 5:1
One option for the detector technology to implement the Lynx x-ray microcalorimeter (LXM) focal plane arrays is the metallic magnetic calorimeter (MMC). Two-dimensional imaging arrays of MMCs measure the energy of x-ray photons by using a paramagneti
Autor:
Thomas R. Stevenson, John E. Sadleir, Sang Jun Lee, S. E. Busch, Megan E. Eckart, Jan-Patrick Porst, George M. Seidel, Caroline A. Kilbourne, Frederick S. Porter, Joseph S. Adams, M. A. Balvin, Stephen J. Smith, Peter C. Nagler, Simon R. Bandler, R. L. Kelley
Publikováno v:
Journal of Low Temperature Physics. 176:617-623
We have developed prototype arrays of metallic magnetic calorimeters for applications in X-ray astronomy. Each pixel consists of an all-gold X-ray absorber in good thermal contact to a gold-erbium paramagnetic thin film thermometer that is operated i
Autor:
Wen-Ting Hsieh, Thomas R. Stevenson, Kevin L. Denis, J.-P. Porst, Joseph S. Adams, Stephen J. Smith, Dan Kelly, George M. Seidel, Peter C. Nagler, Simon R. Bandler, John E. Sadleir, M. A. Balvin
Publikováno v:
Journal of Low Temperature Physics. 167:455-460
The ideal X-ray camera for astrophysics would have more than a million pixels and provide an energy resolution of better than 1 eV FWHM for energies up to 10 keV. We have microfabricated and characterized thin-film magnetic penetration thermometers (
Autor:
Huamán-Castilla, Nils Leander1,2 (AUTHOR) nhuamanc@unam.edu.pe, Allcca-Alca, Erik Edwin1,2 (AUTHOR) frankhervas17@gmail.com, Hervas Nina, Frank1,2 (AUTHOR) nleonc@unam.edu.pe, León-Calvo, Nilton Cesar1,2 (AUTHOR) yvilcanquic@unam.edu.pe, Zirena Vilca, Franz3 (AUTHOR) fzirenav@unam.edu.pe, Vilcanqui Chura, Yesica Luz1,2 (AUTHOR)
Publikováno v:
Molecules. Nov2024, Vol. 29 Issue 21, p5018. 13p.