Zobrazeno 1 - 10
of 39
pro vyhledávání: '"M Simnacher"'
Publikováno v:
Biomedizinische Technik/Biomedical Engineering. 50:400-403
AIM OF THE STUDY Mechanical lever-out tests were performed in vitro to investigate the initial stability of press fit acetabular cups. METHOD Five different uncemented, hemispherical press-fit cups were implanted in a standardized manner into Sawbone
Publikováno v:
Biomedizinische Technik/Biomedical Engineering. 50:314-319
Dislocation is a severe complication after total hip replacement which may cause revision surgery in some cases. The use of constraint inserts that are coupled to the femoral head by a snapping mechanism provides an opportunity for treatment of recur
Publikováno v:
Zeitschrift für Orthopädie und ihre Grenzgebiete. 142:577-585
AIM Recurrent dislocation after total hip replacement is a severe complication, which requires specific treatment and implants. The purpose of the present study was to compare a constraint liner with an elevated rim and standard liner regarding their
Publikováno v:
2010 Advanced Technologies for Enhancing Quality of Life.
Distal radius fractures are typical and frequent fracture of elderly woman with reduced bone density. The angle stable plate, often also multidirectional is today the most common stabilisation device. Because of the introduction of bulky and bended i
Publikováno v:
Biomedizinische Technik. Biomedical engineering. 50(12)
Mechanical lever-out tests were performed in vitro to investigate the initial stability of press fit acetabular cups.Five different uncemented, hemispherical press-fit cups were implanted in a standardized manner into Sawbones, Polyurethane foam bloc
Publikováno v:
Biomedizinische Technik. Biomedical engineering. 50(10)
Dislocation is a severe complication after total hip replacement which may cause revision surgery in some cases. The use of constraint inserts that are coupled to the femoral head by a snapping mechanism provides an opportunity for treatment of recur
Publikováno v:
Zeitschrift fur Orthopadie und ihre Grenzgebiete. 142(5)
Recurrent dislocation after total hip replacement is a severe complication, which requires specific treatment and implants. The purpose of the present study was to compare a constraint liner with an elevated rim and standard liner regarding their ran
Publikováno v:
Bioceramics in Joint Arthroplasty ISBN: 9783798514171
Ultrahigh molecular weight polyethylene (UHMWPE) was introduced in total hip arthroplasty by Charnley in 1962 as a bearing material articulating against a stainless steel ball head [3]. This combination prooted to be highly successful clinically in t
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::7ad7c9910742c28b1569149bb69e3315
https://doi.org/10.1007/978-3-642-85763-8_5
https://doi.org/10.1007/978-3-642-85763-8_5
Publikováno v:
Injury. 43:S24-S25
Publikováno v:
Clinical biomechanics (Bristol, Avon). 16(3)
Objective. To identify an augmentation technique which would provide mechanical protection for the healing posterior cruciate ligament. Design. Six human knee specimens were tested in vitro for posterior knee joint stability after augmenting the cut