Zobrazeno 1 - 10
of 45
pro vyhledávání: '"M Mihelin"'
Publikováno v:
Muscle & Nerve. 15:449-454
Electrical microstimulation of motor axons in conjunction with single fiber EMG (SFEMG) is increasingly used to measure the jitter of the motor endplates. This study examines the jitter of the stimulation site on the axon when stimulus strength is at
Autor:
Joze Trontelj, M Mihelin
Publikováno v:
Wiley Encyclopedia of Biomedical Engineering
Needle electromyography (EMG), i.e., extracellular recording of action potentials of muscle fibers with intramuscular electrodes, is a valuable diagnostic method in clinical medicine. It allows the recognition of different types of spontaneous activi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::04cf32ba727510100c5d777ed5629d9e
https://doi.org/10.1002/9780471740360.ebs0821
https://doi.org/10.1002/9780471740360.ebs0821
Publikováno v:
Electromyography
This chapter contains sections titled: Anatomical and Physiological Background of Intramuscular Recording Recording Characteristics of Needle Electrodes Conventional Needle EMG Special Needle Recording Techniques Physical Characteristics of Needle EM
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::4a9efd807c1c0e21d28c50c36478b505
https://doi.org/10.1002/0471678384.ch2
https://doi.org/10.1002/0471678384.ch2
Publikováno v:
Neuroprosthetics: from Basic Research to Clinical Applications ISBN: 9783642802133
Neuroprosthetics: from Basic Research to Clinical Applications
Neuroprosthetics: from Basic Research to Clinical Applications
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::28883519bc76acf110f71d0bf5f87e9d
https://doi.org/10.1007/978-3-642-80211-9_16
https://doi.org/10.1007/978-3-642-80211-9_16
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
Musclenerve. 15(4)
Electrical microstimulation of motor axons in conjunction with single fiber EMG (SFEMG) is increasingly used to measure the jitter of the motor endplates. This study examines the jitter of the stimulation site on the axon when stimulus strength is at
Publikováno v:
Musclenerve. 14(8)
Direct electrical stimulation with paired pulses at varied intervals was used to study the propagation velocity and action potential amplitude recovery functions (VRF and ARF) of single muscle fibers. Following a subnormal period with slowed conducti
Publikováno v:
Journal of neurology, neurosurgery, and psychiatry. 53(1)
Direct stimulation of muscle fibres with a regular 10 Hz rate, three computer generated random rhythms and a sequence of voluntary discharges was used to quantify the interdischarge interval (IDI) dependent jitter due to velocity recovery function (V
Publikováno v:
International Journal of Bio-Medical Computing. 10:451-459
In single fibre electromyography (SFEMG) an exact measurement and computation of a number of time parameters is required. This paper describes a low-cost microprocessor-based measurement system for SFEMG data acquisition, computation of the parameter
Publikováno v:
Journal of Neurology, Neurosurgery & Psychiatry. 49:677-685
This single fibre EMG study compares the standard method of neuromuscular jitter measurement in voluntarily activated muscle to that by intramuscular electrical stimulation of motor axons in a group of normal subjects. The latter method avoids the in