Autor:
P R, Roberts, S, Allen, T, Betts, J M, Morgan, J F, Urban, T, Whitman, D E, Euler, M J, Kallok
Publikováno v:
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 4(1)
The aim of this study was to identify the optimal position on the chest wall to place an implant able cardioverter defibrillator in a two-electrode system, consisting of a right ventricular electrode and active can.Defibrillation thresholds (DFT) wer
Autor:
P R, Roberts, S, Allen, D C, Smith, J F, Urban, D E, Euler, R W, Dahl, M J, Kallok, J M, Morgan
Publikováno v:
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 3(3)
Conventional implantable cardioverter defibrillators employ endocardial (shock) electrodes with a lead located in the right ventricular apex (RV) and a "hot-can" electrode located subcutaneously in the left pectoral region. In the event of a high def
Publikováno v:
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 3(1)
Defibrillation energy requirements of epicardial implantable cardioverter defibrillator systems are generally lower than endovascular systems currently used. The former has the disadvantage of requiring a thoracotomy and so has a greater morbidity an
Publikováno v:
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2(4)
We report a single center's preliminary clinical experience of the Sentinel (Angeion, Minneapolis, MN) implantable cardioverter defibrillator (ICD), which employs novel technologies that offer the potential for significant reduction in ICD size. Thir
Autor:
Clayton L. Birkett, Richard E. Kerber, Robert A. Kieso, Danita M. Yoerger, M J Kallok, Kirk T. Spencer, Robin S. Smith
Publikováno v:
Circulation. 89(5)
BACKGROUND A directionally changing shock electrical vector could facilitate defibrillation by depolarizing myocytes with different orientations vis-à-vis the shock field. Such a changing vector can be achieved by a new waveform for transthoracic de
Publikováno v:
Journal of applied physiology: respiratory, environmental and exercise physiology. 54(1)
Axial loads were applied around the circumference of an airway lumen by pulling on a cup-shaped anchor that embedded itself in the airway wall. Axial displacements were measured as a function of distance from the load, and the data were compared to t
Autor:
M. J. Kallok, G. O. Hartzler
Publikováno v:
Cardiac Pacing ISBN: 9783642723698
Ninety intracardiac direct current shocks ranging 0.1–5.0 joule were administered to 12 awake patients utilizing a unique transvenous electrode catheter. Fifty-one of 73 (70%) of all ventricular tachycardia episodes and 2 of 2 supraventricular tach
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::6f4360f9313da126954b8818b9ff2749
https://doi.org/10.1007/978-3-642-72367-4_120
https://doi.org/10.1007/978-3-642-72367-4_120
Publikováno v:
Medical instrumentation. 20(1)
The influence of epicardial electrode surface area and implant site on sequential pulse defibrillation threshold was investigated in four isolated heart preparations. Electrodes with surface areas of 2.5, 5.0, and 10.0 cm2 were each sutured, in rando
Publikováno v:
Medical instrumentation. 20(3)
A technique is described that reduces defibrillation threshold for automatic implantable defibrillators, permits either reducing the size of the pulse generator or increasing the effectiveness of the pulse generator, and provides an increased safety
Publikováno v:
Medical instrumentation. 21(3)
We compared the parameters describing the defibrillation threshold in patients with normal hearts and in patients with ischemic heart disease, using a special electrode system and sequential pulses of current. Twenty-eight patients consented to the s