Autor:
M F Moyers
Publikováno v:
Physics in Medicine and Biology. 53:N165-N173
A useful tool for verifying segmental or dynamic treatments with multiple multi-leaf collimator positions, spinning range modulator propellors or magnetically scanned beams would be a film with a linear dose response up to several hundred centiGray,
Publikováno v:
Technology in Cancer Research & Treatment. 6:205-211
A proton microbeam has been developed to support various research endeavors. Test subjects may be irradiated from any angle with respect to the vertical because the beamline is contained within a rotating gantry used for human patients. Converting fr
Autor:
M F, Moyers
Publikováno v:
Medical physics. 41(6)
Adequate evaluation of the results from multi-institutional trials involving light ion beam treatments requires consideration of the planning margins applied to both targets and organs at risk. A major uncertainty that affects the size of these margi
Publikováno v:
Medical physics. 41(1)
Compare the dose per monitor unit at different proton treatment facilities using three different dosimetry methods.Measurements of dose per monitor unit were performed by a single group at eight facilities using 11 test beams and up to six different
Publikováno v:
Medical physics. 38(10)
Previous dosimetry protocols allowed calibrations of proton beamline dose monitors to be performed in plastic phantoms. Nevertheless, dose determinations were referenced to absorbed dose-to-muscle or absorbed dose-to-water. The IAEA Code of Practice
Autor:
M F, Moyers, G A, Nelson
Publikováno v:
Medical physics. 36(8)
Thermoluminescent dosimeters are well established for performing calibrations in radiotherapy and for monitoring dose to personnel exposed to low linear energy transfer (LET) ionizing radiation. Patients undergoing light ion therapy and astronauts en
Publikováno v:
Medical physics. 35(1)
Proton beams offer several advantages over conventional radiation techniques for treating cancer and other diseases. These advantages might be negated if the leakage and scatter radiation from the beamline and patient are too large. Although the leak
Publikováno v:
Medical physics. 34(6)
Delivery of therapeutic proton beams requires an absolute energy accuracy of +/-0.64 to 0.27 MeV for patch fields and a relative energy accuracy of +/-0.10 to 0.25 MeV for tailoring the depth dose distribution using the energy stacking technique. Ach
Publikováno v:
In vivo (Athens, Greece). 15(3)
The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-d
Publikováno v:
Anticancer research. 20(6B)
The major goal of this study was to determine if treatment with the newly constructed plasmid vector for tumor necrosis factor-alpha (pGL1-TNF-alpha) could enhance the radiation-induced growth reduction of C6 rat glioma. In addition, two different fo