Zobrazeno 1 - 9
of 9
pro vyhledávání: '"Lynn Cook Winterton"'
Autor:
Simon Kilvington, Lynn Cook Winterton
Publikováno v:
Optometry and Vision Science
SIGNIFICANCE Hydrogen peroxide (H2O2) disinfection systems are contact-lens-patient problem solvers. The current one-step, criterion-standard version has been widely used since the mid-1980s, without any significant improvement. This work identifies
Autor:
Rachael C. Peterson, Joachim Nick, James S. Wolffsohn, Lynn Cook Winterton, John Martin Lally
Publikováno v:
Contact Lens and Anterior Eye. 29:127-134
Purpose Polyvinyl alcohol (PVA) is a successful tear film stabiliser and is widely used in comfort drops and some soft contact lens materials. A PVA-containing lens, nelfilcon A has been modified to include additional (non-functional) PVA in order to
Publikováno v:
Journal of Biomedical Materials Research. 54:597-607
The influence of ultra-thin (i.e., 5-50 nm) plasma polymer coatings on siloxane-based hydrogel contact lenses was investigated by electrochemical impedance spectroscopy (EIS). Impedance measurements as a function of frequency (Bode plots) were taken
Autor:
Larry Alvord, John Court, Tony Davis, Jürgen Vogt, Lynn Cook Winterton, Klaus Schindhelm, Courtney Flem Morgan
Publikováno v:
Optometry and Vision Science. 75:30-36
Lotrafilcon A is a biphasic block-copolymer, comprising a highly permeable siloxane-based polymeric phase, coupled with a water phase (hydrogel phase). The high oxygen permeability of this material, and the fact that it is a hydrogel, places it outsi
Publikováno v:
Optometry and vision science : official publication of the American Academy of Optometry. 87(2)
Autor:
Manal M. Gabriel, Richard E. Weisbarth, Robin L. Chalmers, Lynn Cook Winterton, Marian B. Miller, Melanie George, Joseph Rappon
Publikováno v:
Eyecontact lens. 33(6 Pt 2)
Contact lenses are a safe and effective mode of vision correction used by more than 100 million people worldwide, yet some adverse responses to microbial contamination of contact lenses still occur. Various medical devices, including contact lens cas
Publikováno v:
Cornea. 26(6)
Purpose Since 1991, multilayer mathematical in vivo oxygenation models have been created to predict normal corneal oxygenation with contact lens wear. From these models, there have been assertions that most hydrogel contact lenses allow 97%-98% of no
Publikováno v:
Journal of colloid and interface science. 197(1)
The behavior of the model proteins, lysozyme, myoglobin, and beta-casein, pretreated in urea and/or dithiothreitol, at air/solution interfaces was studied by surface pressure-area techniques. The data suggested that in the absence of pretreatments th
Publikováno v:
Cornea. 6:160