Zobrazeno 1 - 10
of 65
pro vyhledávání: '"Lukas Capek"'
Publikováno v:
Clinical Case Reports, Vol 12, Iss 9, Pp n/a-n/a (2024)
Key Clinical Message In the anatomically complex terrain of the head and neck, the use of 3D intraoperative models serves as an effective verification tool, determining the size, shape, and number of foreign bodies. This allows the main operator to m
Externí odkaz:
https://doaj.org/article/69110d248b8140ddbe08e2a66e5a8057
Autor:
Lukas Capek, Daniel Schwarz
Publikováno v:
Heliyon, Vol 10, Iss 12, Pp e32664- (2024)
Background: 3D printing is one of the fastest-growing technologies in medicine, but it is essential to have a system for 3D printing documentation that is accessible for not only clinical engineers and surgeons, but also quality managers and data-pri
Externí odkaz:
https://doaj.org/article/c05770216441419c937ea0b614bf70ba
Publikováno v:
Case Studies in Chemical and Environmental Engineering, Vol 6, Iss , Pp 100275- (2022)
The mechanical properties of an electrospun membrane by adding a lamination process to its production are improved. The aim is to improve the maximum force and the deformation energy obtained during a uniaxial tensile test. The investigated parameter
Externí odkaz:
https://doaj.org/article/24cdefd72c5843769ec8b6a514815ea9
Autor:
Ales Hrouda, Radek Jirkovec, Petra Hamrikova, Maarten Vanierschot, Kathleen Denis, Lukas Capek
Publikováno v:
Royal Society Open Science, Vol 8, Iss 12 (2021)
Aseptic loosening due to periprosthetic osteolysis has been accepted as one of the leading causes of revision procedures in patients with previous joint arthroplasty. Recently, several strategies for suppression of osteolysis were proposed, mostly ba
Externí odkaz:
https://doaj.org/article/3312e029f89644c595f41558dc5420e1
Autor:
Jakub Erben, Katerina Blatonova, Tomas Kalous, Lukas Capek, Lubos Behalek, Martin Boruvka, Jiri Chvojka
Publikováno v:
Polymers, Vol 14, Iss 24, p 5528 (2022)
Recent years have observed a significant increase in the use of degradable materials in medicine due to their minimal impact on the patient and broad range of applicability. The biodegradable polymer Polydioxanone (PDO) provides a good example of the
Externí odkaz:
https://doaj.org/article/f454063af21c42749b30e98fc5d46d29
Publikováno v:
Journal of Clinical Neuroscience. 105:45-50
This study is focused on the opening technique of the cervical vertebrae during laminoplasty which serves to substantially reduce the most severe adverse effects of the simple resection of posterior vertebral elements. This computational study aims t
Publikováno v:
Computer Methods in Biomechanics and Biomedical Engineering. :1-9
The paper introduces the concept of the rational design of a deployable humeral intramedullary nail plug based on a honeycomb structure used for the surgical treatment of humeral shaft fractures. The concept serves for to restore the axial alignment
Publikováno v:
Textile Research Journal. 92:2298-2305
This study presents a new design for the jaws used in the uniaxial tensile testing of PA6 electrospun membranes. The aims of the new design are both to accelerate the clamping process and additionally reduce the paper waste created by paper frames. I
Autor:
Dagmar Polakova, Lukas Capek, Martin Bartos, Pavel Kejzlar, Miroslava Rysova, Lenka Martinova, Alena Sevcu
Publikováno v:
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 236:539-546
Complex assessment of gradual changes in scaffold morphology and stiffness is an essential step in bone filler development. Current approach, however, does not reflect long term cell proliferation effect as the mechanical tests are usually conducted
Autor:
Brigita Kolcavova-Sirkova, Stepanka Dzanova, Irena Lenfeldova, Lukas Capek, Petra Hamrikova, Jiri Chvojka
Publikováno v:
The Journal of The Textile Institute. 113:1723-1730
The use of needles in surgical practice goes beyond the general suturing of tissue and stitching. With the ever-increasing role of robotic surgery, it is essential not to underestimate the importan...