Zobrazeno 1 - 10
of 19
pro vyhledávání: '"Lotte L. Nieuwenhuis"'
Autor:
Lotte L. Nieuwenhuis, Jan-Hein T. M. van Waesberghe, Mandy M.A. Conijn, Wouter J. K. Hehenkamp, Hans A.M. Brölmann, Judith A.F. Huirne, Barbara Stoelinga
Publikováno v:
Ultrasound in medicine & biology, 44(8), 1654-1663. Elsevier USA
Ultrasound in Medicine and Biology, 44(8), 1654-1663. Elsevier USA
Stoelinga, B, Hehenkamp, W J K, Nieuwenhuis, L L, Conijn, M M A, van Waesberghe, J H T M, Brölmann, H A M & Huirne, J A F 2018, ' Accuracy and Reproducibility of Sonoelastography for the Assessment of Fibroids and Adenomyosis, with Magnetic Resonance Imaging as Reference Standard ', Ultrasound in Medicine and Biology, vol. 44, no. 8, pp. 1654-1663 . https://doi.org/10.1016/j.ultrasmedbio.2018.03.027
Ultrasound in Medicine and Biology, 44(8), 1654-1663. Elsevier USA
Stoelinga, B, Hehenkamp, W J K, Nieuwenhuis, L L, Conijn, M M A, van Waesberghe, J H T M, Brölmann, H A M & Huirne, J A F 2018, ' Accuracy and Reproducibility of Sonoelastography for the Assessment of Fibroids and Adenomyosis, with Magnetic Resonance Imaging as Reference Standard ', Ultrasound in Medicine and Biology, vol. 44, no. 8, pp. 1654-1663 . https://doi.org/10.1016/j.ultrasmedbio.2018.03.027
The aims of this prospective diagnostic evaluation study were (i) to estimate the inter-observer agreement and reproducibility of real-time sonoelastography and real-time gray-scale ultrasound in the measurement of uterine and fibroid volumes; (ii) t
Autor:
Wouter J. K. Hehenkamp, Judith A.F. Huirne, Hans A.M. Brölmann, Alieke L. Keizer, Jos W. R. Twisk, Lotte L. Nieuwenhuis
Publikováno v:
Journal of Ultrasound in Medicine. 37:191-199
Objectives To investigate the accuracy and reliability of 3-dimensional (3D) transvaginal sonography in classifying submucous fibroids using the International Federation of Gynecology and Obstetrics PALM-COEIN (polyp, adenomyosis, leiomyoma, malignan
Autor:
J.W.R. Twisk, A.L. Keizer, Wouter J. K. Hehenkamp, Barbara Stoelinga, J.A.F. Huirne, Ham Brölmann, Lotte L. Nieuwenhuis
Publikováno v:
BJOG: An International Journal of Obstetrics and Gynaecology, 125(5), 577-584. Wiley Online Library
Nieuwenhuis, L L, Keizer, A L, Stoelinga, B, Twisk, J W R, Hehenkamp, W J K, Brölmann, H A M & Huirne, J A F 2018, ' Fibroid vascularisation assessed with three-dimensional power Doppler ultrasound is a predictor for uterine fibroid growth : A prospective cohort study ', BJOG: An International Journal of Obstetrics and Gynaecology, vol. 125, no. 5, pp. 577-584 . https://doi.org/10.1111/1471-0528.14608
BJOG, 125(5), 577-584. Wiley-Blackwell
Nieuwenhuis, L L, Keizer, A L, Stoelinga, B, Twisk, J W R, Hehenkamp, W J K, Brölmann, H A M & Huirne, J A F 2018, ' Fibroid vascularisation assessed with three-dimensional power Doppler ultrasound is a predictor for uterine fibroid growth : A prospective cohort study ', BJOG: An International Journal of Obstetrics and Gynaecology, vol. 125, no. 5, pp. 577-584 . https://doi.org/10.1111/1471-0528.14608
BJOG, 125(5), 577-584. Wiley-Blackwell
Objective: To analyse fibroid vascularisation measured with three-dimensional (3D) power Doppler in relation to absolute fibroid volume change during 12 months of follow up and in relation to fibroid growth rate per year. Design: A prospective cohort
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::61e210ad685af61d00be13f60c367768
https://research.vumc.nl/en/publications/4da99b59-e137-4357-891f-0bc8ca76ff84
https://research.vumc.nl/en/publications/4da99b59-e137-4357-891f-0bc8ca76ff84
Publikováno v:
Journal of obstetrics and gynaecology, 38(1), 103-109. Informa Healthcare
Journal of Obstetrics and Gynaecology, 38(1), 103-109. Informa Healthcare
Nieuwenhuis, L L, Hehenkamp, W J K, Brölmann, H A M & Huirne, J A F 2018, ' 3D power Doppler in uterine fibroids; influence of gain, cardiac cycle and off-line measurement techniques ', Journal of Obstetrics and Gynaecology, vol. 38, no. 1, pp. 103-109 . https://doi.org/10.1080/01443615.2017.1330323
Journal of Obstetrics and Gynaecology, 38(1), 103-109. Informa Healthcare
Nieuwenhuis, L L, Hehenkamp, W J K, Brölmann, H A M & Huirne, J A F 2018, ' 3D power Doppler in uterine fibroids; influence of gain, cardiac cycle and off-line measurement techniques ', Journal of Obstetrics and Gynaecology, vol. 38, no. 1, pp. 103-109 . https://doi.org/10.1080/01443615.2017.1330323
This study answers the question of whether ultrasound machine settings and the cardiac cycle can influence 3D power Doppler (3D PD) indices in the evaluation of uterine fibroid vascularisation. These parameters were reported to affect the vascular in
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::41d48ae037692970c3860a932370701c
https://pure.amc.nl/en/publications/3d-power-doppler-in-uterine-fibroids-influence-of-gain-cardiac-cycle-and-offline-measurement-techniques(848f3a08-5872-4900-8805-20f24666fd55).html
https://pure.amc.nl/en/publications/3d-power-doppler-in-uterine-fibroids-influence-of-gain-cardiac-cycle-and-offline-measurement-techniques(848f3a08-5872-4900-8805-20f24666fd55).html
Autor:
Frederik J.R. Hermans, Mariska M.G. Leeflang, T Justin Clark, Wouter J. K. Hehenkamp, Judith A.F. Huirne, Lotte L. Nieuwenhuis, A.J. Marjolein Bij de Vaate, Ben W.J. Mol, Hans A.M. Brölmann
Publikováno v:
The Cochrane Library
Nieuwenhuis, L L, Hermans, F J R, de Vaate, A J M B, Leeflang, M M G, Brolmann, H A M, Hehenkamp, W J K, Mol, B W J, Clark, T J & Huirne, J A F 2017, ' Three-dimensional saline infusion sonography compared to two-dimensional saline infusion sonography for the diagnosis of focal intracavitary lesions ', Cochrane Database of Systematic Reviews, no. 5, CD011126 . https://doi.org/10.1002/14651858.CD011126.pub2
Nieuwenhuis, L L, Hermans, F J R, de Vaate, A J M B, Leeflang, M M G, Brolmann, H A M, Hehenkamp, W J K, Mol, B W J, Clark, T J & Huirne, J A F 2017, ' Three-dimensional saline infusion sonography compared to two-dimensional saline infusion sonography for the diagnosis of focal intracavitary lesions ', Cochrane Database of Systematic Reviews, no. 5, CD011126 . https://doi.org/10.1002/14651858.CD011126.pub2
Background Focal abnormalities most commonly acquired within the uterine cavity include endometrial polyps (arising from the endometrium) and submucous fibroids (arising from the myometrium). These benign abnormalities can cause several problems, inc
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::c47db18aabd1c1803cfb0b1e7fe516e1
https://doi.org/10.1002/14651858.cd011126.pub2
https://doi.org/10.1002/14651858.cd011126.pub2
Autor:
Heleen E. Betjes, Hans A.M. Brölmann, Martijn W. Heymans, Wouter J. K. Hehenkamp, Lotte L. Nieuwenhuis, Judith A.F. Huirne
Publikováno v:
Journal of Clinical Ultrasound. 43:171-178
Background To evaluate the interobserver agreement and discriminating value of three-dimensional power Doppler ultrasound (3D PDUS) in patients with fibroids. Methods An observational prospective cohort study in 19 patients with fibroids. 3D PDUS was
Autor:
Marjolein A.J. Bij de Vaate, Lotte L. Nieuwenhuis, Martijn W. Heymans, Hans A.M. Brölmann, Wouter J. K. Hehenkamp, Marchien W. van Baal, Judith A.F. Huirne
Publikováno v:
European Journal of Obstetrics and Gynecology and Reproductive Biology, 175, 67-74. Elsevier Ireland Ltd
Nieuwenhuis, L L, bij de Vaate, A J M, Hehenkamp, W J K, Heymans, M W, van Baal, M, Brölmann, H A M & Huirne, J A F 2014, ' Diagnostic and clinical value of 3D gel installation sonohysterography in addition to 2D gel installation sonohysterography in the assessment of intrauterine abnormalities ', European Journal of Obstetrics and Gynecology and Reproductive Biology, vol. 175, pp. 67-74 . https://doi.org/10.1016/j.ejogrb.2014.01.015
Nieuwenhuis, L L, bij de Vaate, A J M, Hehenkamp, W J K, Heymans, M W, van Baal, M, Brölmann, H A M & Huirne, J A F 2014, ' Diagnostic and clinical value of 3D gel installation sonohysterography in addition to 2D gel installation sonohysterography in the assessment of intrauterine abnormalities ', European Journal of Obstetrics and Gynecology and Reproductive Biology, vol. 175, pp. 67-74 . https://doi.org/10.1016/j.ejogrb.2014.01.015
Objective: To study the diagnostic value of three-dimensional gel instillation sonography (3D GIS) in addition to two-dimensional (2D) GIS in the assessment of intrauterine abnormalities. Secondly, the clinical value of 3D GIS in the planning for hys
Autor:
Alieke L, Keizer, Lotte L, Nieuwenhuis, Jos W R, Twisk, Judith A F, Huirne, Wouter J K, Hehenkamp, Hans A M, Brölmann
Publikováno v:
Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 37(1)
Objectives—To investigate the accuracy and reliability of 3-dimensional (3D) transvaginal sonography in classifying submucous fibroids using the International Federation of Gynecology and Obstetrics PALM-COEIN (polyp, adenomyosis, leiomyoma, malign
Three-dimensional saline infusion sonohysterography for the diagnosis of focal intracavitary lesions
Autor:
Frederik J.R. Hermans, T Justin Clark, A.J. Marjolein Bij de Vaate, Lotte L. Nieuwenhuis, Hans A.M. Brölmann, Mariska M.G. Leeflang, Ben W.J. Mol, Judith A.F. Huirne
Publikováno v:
The Cochrane Library
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::8c191e3c53a29318e959cc5e347ad89b
https://doi.org/10.1002/14651858.cd011126
https://doi.org/10.1002/14651858.cd011126
Autor:
Martijn W. Heymans, Marjolein A.J. Bij de Vaate, Lotte L. Nieuwenhuis, Wouter J. K. Hehenkamp, Hans A.M. Brölmann, Marchien W. van Baal, Judith A F Huirne
Publikováno v:
Nieuwenhuis, L L, bij de Vaate, A J M, Hehenkamp, W J K, Heijmans, M W, van Baal, M W M, Brölmann, H A M & Huirne, J A F 2014, ' Reproducibility of three-dimensional gel installation sonohysterography in the assessment and classification of intrauterine abnormalities ', European Journal of Obstetrics and Gynecology and Reproductive Biology, vol. 179, pp. 141-146 . https://doi.org/10.1016/j.ejogrb.2014.05.010
European Journal of Obstetrics and Gynecology and Reproductive Biology, 179, 141-146. Elsevier Ireland Ltd
European Journal of Obstetrics and Gynecology and Reproductive Biology, 179, 141-146. Elsevier Ireland Ltd
Objective: Purpose of this study is to determine the interobserver and intraobserver variability of 3D GIS in the assessment of intrauterine abnormalities. Study design: Forty five 3D volumes were randomly selected from a larger prospective cohort st
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::b324967f0093004f12fdf28b2ac9141e
https://research.vumc.nl/en/publications/16a9b42c-81d7-446f-b65b-df5389c6d124
https://research.vumc.nl/en/publications/16a9b42c-81d7-446f-b65b-df5389c6d124