Publikováno v:
IEEE Access, Vol 9, Pp 63213-63218 (2021)
Emergency control system is the combination of power grid side Battery Energy Storage System (BESS) and Precise Load Shedding Control System (PLSCS). It can provide an emergency support operation of power grid. The structure and commission test resul
Externí odkaz:
https://doaj.org/article/633c30e40fe14961b87b967fff616de9
Publikováno v:
The Journal of Engineering (2019)
The large shunt capacitances on both sides of VSC-HVDC transmission line will block and reflect the travelling waves when a fault occurs on DC cable lines. When a forward fault occurs, the protection will detect the arrival of forward and backward tr
Externí odkaz:
https://doaj.org/article/9414f8339e074518829bde02855c4156
Publikováno v:
The Journal of Engineering (2019)
Due to the labyrinthine topology of the MMC-MVDC system, identification of the faulty feeder especially for a single-pole-to-ground (SPTG) fault is a challenging task. Based on the characteristics analysis of capacitance charge–discharge, this arti
Externí odkaz:
https://doaj.org/article/9eeb39209a414a0aac461ed0c6b365c4
Publikováno v:
Sensors, Vol 20, Iss 16, p 4365 (2020)
The modular magnetic suspension platform depends on multi degree of freedom of Lorentz force actuators for large bearing capacity, high precision positioning and structure miniaturization. To achieve the integration of vertical driving force and hori
Externí odkaz:
https://doaj.org/article/3d096c56cc204085b8516ba427443ab7
Publikováno v:
Energies, Vol 11, Iss 8, p 2076 (2018)
Nowadays, the efficient and reliable protection and location schemes for MMC-MVDC (Modular Multilevel Converter-Medium Voltage Direct Current) grid are few. This paper is the first to propose a scheme to not only protect the feeders and the busbar, b
Externí odkaz:
https://doaj.org/article/86c57267f2a54bde864d36fb9280a216
Publikováno v:
Energies, Vol 11, Iss 8, p 2021 (2018)
This paper presents a novel pilot protection scheme of DC cable line in voltage-source-converter (VSC) based multi-terminal DC (MTDC) grids, which utilizes a novel phase-mode transformation to decouple the bipolar DC cable current into six mode and i
Externí odkaz:
https://doaj.org/article/63571638af154d9293f5f779a9d9ad4d
Publikováno v:
IET Generation, Transmission & Distribution. 14:223-233
As a modular multilevel converter-based medium-voltage direct current (MMC-MVDC) distribution grid mostly utilises small current grounding modes, the weak fault current for single-pole-to-ground (SPTG) fault is very difficult to detect especially in
Publikováno v:
International Journal of Electrical Power & Energy Systems. 109:198-206
This paper proposes a novel directional pilot protection for VSC-MTDC frequency-varying cable lines. Based on a new phase-mode transformation to decouple the bipolar DC cable, this paper utilizes the propagation time difference between 6-th mode forw
Publikováno v:
The Journal of Engineering (2019)
The large shunt capacitances on both sides of VSC-HVDC transmission line will block and reflect the travelling waves when a fault occurs on DC cable lines. When a forward fault occurs, the protection will detect the arrival of forward and backward tr
Publikováno v:
The Journal of Engineering (2019)
Due to the labyrinthine topology of the MMC-MVDC system, identification of the faulty feeder especially for a single-pole-to-ground (SPTG) fault is a challenging task. Based on the characteristics analysis of capacitance charge–discharge, this arti