Zobrazeno 1 - 10
of 33
pro vyhledávání: '"Linde, Thomas"'
Autor:
Linde, Thomas, Schlegel, Stephan
The partial discharge (PD) characteristics of polymeric insulation foil are investigated under harmonic distorted voltage waveforms. Distorted voltage waveforms can cause intensified aging, leading to preliminary insulation failure, especially when P
Externí odkaz:
https://tud.qucosa.de/id/qucosa%3A94492
https://tud.qucosa.de/api/qucosa%3A94492/attachment/ATT-0/
https://tud.qucosa.de/api/qucosa%3A94492/attachment/ATT-0/
The insulation of the electrical equipment in medium and high-voltage grids is subjected to significant electrical and thermal stresses. The switching characteristic of the increasing number of power electronic devices in electric grids leads to the
Externí odkaz:
https://tud.qucosa.de/id/qucosa%3A80628
https://tud.qucosa.de/api/qucosa%3A80628/attachment/ATT-0/
https://tud.qucosa.de/api/qucosa%3A80628/attachment/ATT-0/
Harmonic distorted voltage waveforms can lead to excessive heat in the insulation of electrical equipment. The prospectively increasing number of power electronic devices in electrical grids requires the careful examination of the conse- quences of h
Externí odkaz:
https://tud.qucosa.de/id/qucosa%3A78265
https://tud.qucosa.de/api/qucosa%3A78265/attachment/ATT-0/
https://tud.qucosa.de/api/qucosa%3A78265/attachment/ATT-0/
The increasing propagation of power electronics technologies and the related operational equipment such as inverter-fed drives and solid-state transformers in electrical grids lead to growing harmonic distortion of the voltage waveform. Harmonics mod
Externí odkaz:
https://tud.qucosa.de/id/qucosa%3A78261
https://tud.qucosa.de/api/qucosa%3A78261/attachment/ATT-0/
https://tud.qucosa.de/api/qucosa%3A78261/attachment/ATT-0/
Autor:
Linde, Thomas, Backhaus, Karsten
The increasing number of power electronic devices in medium voltage networks lead to a harmonic distortion of the voltage waveforms in electrical systems. Medium frequency components up to several kHz are superimposed on the fundamental grid voltage.
Externí odkaz:
https://tud.qucosa.de/id/qucosa%3A94503
https://tud.qucosa.de/api/qucosa%3A94503/attachment/ATT-0/
https://tud.qucosa.de/api/qucosa%3A94503/attachment/ATT-0/
The most main wall insulations of rotating electrical high voltage machines consists of several layers of wound mica tape impregnated with epoxy resins. Methylhexahydrophthalic anhydride and Hexahydrophthalic anhydride are the state-of-the-art curing
Externí odkaz:
https://tud.qucosa.de/id/qucosa%3A76405
https://tud.qucosa.de/api/qucosa%3A76405/attachment/ATT-0/
https://tud.qucosa.de/api/qucosa%3A76405/attachment/ATT-0/
Autor:
Linde, Thomas
Publikováno v:
Refugee Survey Quarterly, 2011 Jan 01. 30(1), 89-99.
Externí odkaz:
https://www.jstor.org/stable/45054480
Publikováno v:
2021 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP).
Harmonic distorted voltage waveforms can lead to excessive heat in the insulation of electrical equipment. The prospectively increasing number of power electronic devices in electrical grids requires the careful examination of the conse- quences of h
Autor:
Linde, Thomas
Publikováno v:
Refugee Survey Quarterly, 2002 Jan 01. 21(3), 235-238.
Externí odkaz:
https://www.jstor.org/stable/45054633
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.