Zobrazeno 1 - 10
of 48
pro vyhledávání: '"Linda M. Sandhaus"'
Publikováno v:
American Journal of Clinical Pathology. 147:507-514
Objectives The purpose of the study was to compare the performance of GloCyte (Advanced Instruments, Norwood, MA), a new semiautomated instrument for cerebrospinal fluid cell counting, with the manual hemocytometer method and the automated Sysmex XN
Autor:
Linda M. Sandhaus
Publikováno v:
Clinics in Laboratory Medicine. 35:93-103
Automated cell counting for body fluids is gradually replacing manual cell counting by hemocytometer. Automation offers potential benefits of improved accuracy, efficiency, and standardization. The addition of body fluid modes to some hematology anal
Publikováno v:
Clinical imaging. 50
Castleman disease (CD) is a rare lymphoproliferative disorder of unknown etiology that may occur anywhere in the lymphatic system. Imaging plays an important role in detecting and staging this disease. Positron Emission Tomography/Magnetic Resonance
Publikováno v:
American journal of clinical pathology. 147(5)
The purpose of the study was to compare the performance of GloCyte (Advanced Instruments, Norwood, MA), a new semiautomated instrument for cerebrospinal fluid cell counting, with the manual hemocytometer method and the automated Sysmex XN (Sysmex, Ko
Publikováno v:
Point of Care: The Journal of Near-Patient Testing & Technology. 13:148-151
The American Academy of Pediatrics recommends measurement of total bilirubin (TBili) in newborns to assess the risk of developing severe neonatal hyperbilirubinemia and bilirubin-induced neurologic dysfunction. In this study, we evaluated the correla
Publikováno v:
Transfusion. 55:756-765
Background Thrombotic thrombocytopenic purpura (TTP) is a life-threatening diagnosis requiring prompt initiation of therapeutic plasma exchange (TPE). Measurement of immature platelet (PLT) fraction (%-IPF) differentiates PLT consumption or destructi
Autor:
Linda M. Sandhaus, Emily L. Wiland, Zhanna Georgievskaya, Mary Ann O'Riordan, Mary Nock, Claudia M. Hoyen
Publikováno v:
Acta Paediatrica. 103:494-497
Aim Automated haematology analysers are increasingly being used. Normal ranges for automated immature granulocyte counts (IG%) are described in adults and children as
Autor:
Linda M. Sandhaus
Publikováno v:
American journal of clinical pathology. 145(3)
Automated body fluid (BF) cell counts performed on hematology analyzers have been steadily replacing manual hemocytometer (counting chamber) cell counts in clinical laboratories. Hematology analyzers with dedicated BF modes are capable of producing a
Publikováno v:
Laboratory Hematology Practice. :673-685
Publikováno v:
American Journal of Clinical Pathology. 134:734-738
The main objectives of the study were to compare manual and automated WBC counts on clear cerebrospinal fluid (CSF) samples. Clear CSF samples from 200 adults and children were studied. Cell counts were performed manually using a hemocytometer and th